Records from 2001 to 2020. Most recent: inspection, 9 December 2020.
Documentation record
Registered dimensions (L × B × D)44.8 ft × 14.0 ft × 6.2 ft
Registered tonnagegross 26 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY CRAFT · LOREAUVILLE, LA, UNITED STATES · built 1977
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portALAMEDA, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 30 January 2026 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it26 - Regulatory (Subpart C or D), Gross Ton
18 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 24
9 December 2020
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7109140
6 February 2020
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6900468
8 January 2020
Drydock Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6885600
17 September 2018
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6542028
6 September 2017
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6260676
8 June 2017
Internal Structural Exam · Drydock Exam · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6169594
10 June 2016
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5902680
8 September 2015
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5233316
4 January 2012
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4218292
12 October 2010
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3868227
14 July 2009
Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3533538
19 September 2008
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3358580
10 January 2008
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3127887
11 December 2007
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3113736
26 October 2007
Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3087595
12 July 2007
Welding Related Inspections Qualification Testing · Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2992595
4 October 2006
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2793349
24 August 2005
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2508302
12 August 2005
Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2455622
2 November 2004
Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2250762
16 October 2003
Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1928337
15 October 2003
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 1929057
10 December 2002
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1716883
10 October 2001
COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1412371
Navigation › Piloting/Steering › Marine Charts
Issued 6 September 2017
Resolved
Charts not up to date.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 September 2017
Resolved 7 September 2017
Resolution: Updated charts on board to the satisfaction of marine inspector
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 6 September 2017
Resolved
Rudder room bilge alarm inoperable.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 September 2017
Resolution: Bilge alarm was fixed to light up and sound for bilge high water in rudder room to the satisfaction of marine inspector.
Lifesaving › Lifefloat › Serviceable
Issued 6 September 2017
Resolved
Lifefloat not servicible.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 September 2017
Resolution: New life float was purchased and installed on board the vessel to the satisfaction of the marine inspector.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 25 October 2007
Resolved
3 life jackets were in unservicable condition. Vessel had 2 extra life jackets, one more is required for total replacement. Reduced total persons allowed onboard to 22 until replacement life jacket is replaced onboard. Provide proof to Coast Guard Marine Inspector.
Due 25 November 2007
Resolved 13 December 2007
Resolution: New replacement life jackets procured and installed on vessel.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 25 October 2007
Resolved
Master does not posses a valid Marine Radio Operator Permit. Master must obtain new radio liscense.
Due 25 November 2007
Resolved 13 December 2007
Resolution: Master passed test and provided proof of registration.
Fire Fighting › Portable CO2 Fire Extinguisher › Marking
Issued 4 October 2006
Resolved
Weather covers for both extinguishers on the aft deck did not have any marking to make them noticeable as an extinguisher station.
Action required: 705 - Other - as specified
Due 4 October 2006
Resolved 4 October 2006
Resolution: Corrected on the spot.
Electrical › Electrical Distribution System (service)
Issued 16 October 2003
Resolved
Provide covers for blank spots in the engine room electrical panel. LEGACY COMPONENT DESC: Panel board
Action required: 705 - Other - as specified
Due 22 November 2003
Resolved 23 October 2003
Lifesaving › Hand Flares › Quantity
Issued 10 December 2002
Resolved
Provide three red hand flares
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 December 2002
Resolved 10 December 2002