MAURY USCG vessel records
← All vessels

DARNIA

DARNIA is a 2017 tank ship. The Coast Guard has recorded 10 inspections since 2018, most recently in May 2025, along with 6 deficiencies.

Records from 2018 to 2025. Most recent: inspection, 11 May 2025.

Built
2017
Last inspected
11 May 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9336464
1480252
Flag
PANAMA
Maury page id
psix-1480252

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded1
Years with a record 5 calendar years (2018–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it30906 - Convention (Subpart B), Gross Ton
12970 - Convention (Subpart B), Net Ton
45695 - Dead Weight, Metric Ton
58937 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 10

11 May 2025 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8132071
29 July 2021 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7270226
6 June 2020 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6987475
16 March 2020 PSC B · COC-CHEM & TVE Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6914401
20 May 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6688638
28 February 2019 Deficiency Check · Administrative Inspection · In-Service Inspection · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6634523
28 February 2019 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6637634
11 February 2019 ISPS II Exam · COC-CHEM & TVE Annual · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6623460
17 January 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6611621
14 January 2018 Ballast Water Examination · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6337004

Deficiency record · 6

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 16 March 2020 Resolved
Controlled tank venting system shall consist of a primary and secondary means to prevent over-pressure and under-pressure conditions in a tank. PSCO found the pressure sensor monitoring system is malfunctioning on cargo tank 5S. IBC Code Ch. 8.3.3 17ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 March 2020
Resolved 22 April 2020
Resolution: Received Class [name withheld] attesting to the satisfactory repair and testing of the Pressure Sensor Monitoring System. See attached report.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 16 March 2020 Resolved
The tank overfill alarm required by paragraph (a) of this section must activate a visible and audible alarm so that it can be seen and heard on the vessel where cargo transfer is controlled and in cargo deck area. PSCO observed that the 1P tank overfill alarm was not operational. Rectify prior to loading cargo tank 1P. 46CFR39.2007(d)(3) 34ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 March 2020
Resolved 22 April 2020
Resolution: Received Class [name withheld] attesting to the satisfactory repair and testing of the COT 1P Overfill alarm. See attached report.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 16 March 2020 Resolved
Each vessel vapor connection flange face must have a permanent stud projecting outward that has a 12.7 millimeter (0.5 inch) diameter and is at least 25.4 millimeters (1 inch) long. It must be located at the top of the flange face, midway between boltholes, and in line with the bolthole pattern. PSCO observed no permanent stud located on any of the vapor connection flange faces at port and starboard manifolds of vessel. 46CFR39.2001(j) 40c
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 16 March 2020
Resolved 6 June 2020
Resolution: Received master's attestation and photo evidence that deficiency was rectified. See attached report.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 16 March 2020 Resolved
"A" class bulkheads shall be capable of preventing the passage of smoke and flame to the end of the one hour standard fire test. PSCO found a 2 inch diameter hole in the "A" class bulkhead bewteen the main machinery space and steering gear space and another 2 inch diameter hole in the "A" class bulkhead between deck foam room and a storage space. 74 SOLAS (2004 cons.) II-2/3.2.4 50ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2020
Resolved 22 April 2020
Resolution: Received Class Report attesting rectification of deficiency by means of welding doubler plates to holes on bulkheads. See attached report.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 28 February 2019 Resolved
15106 - SHIPBOARD OPERATIONS - THE COMPANY SHOULD ESTABLISH AND MAINTAIN PROCEDURES FOR IDENTIFYING ANY TRAINING WHICH MAY BE REQUIRED IN SUPPORT OF THE SAFETY MANAGEMENT SYSTEM AND ENSURE THAT SUCH TRAINING IS PROVIDED FOR ALL PERSONNEL CONCERNED (6.5). THE COMPANY SHOULD ESTABLISH PROCEDURES, PLANS AND INSTRUCTIONS, INCLUDING CHECKLISTS AS APPROPRIATE, FOR KEY SHIPBOARD OPERATIONS CONCERNING THE SAFETY OF THE PERSONNEL, SHIP AND PROTECTION OF THE ENVIRONMENT. THE VARIOUS TAKS SHOULD BE DEFINED AND ASSIGNED TO QUALIFIED PERSONNEL (7). MASTERS AND [name withheld] THAT ALL OOW’S AND ENGINE ROOM STAFF RESPECTIVELY ARE THOROUGHLY FAMILIAR WITH THE OPERATION OF MAIN PROPULSION MACHINERY CONTROL SYSTEMS; INSTRUCTIONS FOR THE OPERATION OF THE MAIN PROPULSION MACHINERY ARE POSTED ON THE BRIDGE AND ENGINE CONTROL ROOM AS STATED IN BRIDGE PROCEDURE MANUAL REV. NO-2 DATED 10-08-2018 PAGE 26 OF 27. FAMILIARIZATION WITH BRIDGE EQUIPMENT CHECKLIST TO INCLUDE ENGINE AND THRUSTER CONTROLS SIGNED BY MASTER, DATED 27-12-2018 AND BY [name withheld], DATED 10-01-2019. THE VESSEL EXPERIENCED LOSS OF PROPULSION WHILE TRANSITING THE NAVIGABLE WATERS OF THE UNITED STATES DUE TO SHIP BEING OPERATED IN COMBINATOR MODE WHILE RECEIVING MULTIPLE COMMANDS CAUSING ENGINE RPMS TO ENTER CRITICAL RPM RANGE RESULTING IN ENGINE SHUTTING DOWN TO PROTECT ENGINE FROM CRITICAL SPEED. CHIEF ENGINEER STATED THAT HE RECEIVED ALARMS INDICATING ENGINE IN CRITICAL RPM RANGE IN ECR PRIOR TO ENGINE SHUTTING DOWN. FOLLOWING ALARMS AND ENGINE SHUTTING DOWN, OPERATING MODE “SEPARATE” WAS SELECTED AND VESSEL WAS PILOTED BACK TO BERTH. ENGINEERING DEPARTMENT STATED “SEPARATE” MODE IS THE APPROPRIATE MODE TO USE DURING MANEUVERING IN RESTRICED WATERS; CAPTAIN STATED HE WAS UNAWARE THERE WERE MULTIPLE CONTROL MODES AS WAS EVIDENCED BY VESSEL LOSING PROPULSION AND PILOT ENDING VOYAGE. ADDITIONALY NO INSTRUCTIONS FOR THE OPERATION OF PROPULSION MACHINERY WERE FOUND POSTED ON BRIDGE ADDRESSING CONTROL MODES. SUBMIT EVIDENCE TO [email withheld] DETAILING HOW APPROPRIATE TRAINING WILL BE CONDUCTED IN ADDITION TO PROVIDING INSTRUCTIONS FOR PROPULSION CONTROL MODES ON NAVIGATION BRIDGE. RECOMMEND INTERNAL SAFETY AUDIT. 74 SOLAS (14) IX/13.1; REF ISM CODE 6.5 AND 7
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 1 March 2019
Resolved 1 March 2019
Resolution: Received, reviewed and accepted proper documentation from Master stating the deficiency was rectified. Master provided documentation that training was held and M/E procedures were posted on the navigation bridge and ECR.
Deck/Cargo › Vapor Control Systems › Liquid Overfill Protection
Issued 14 January 2018 Resolved
0800-Accident Prevention-Each cargo tank of a tankship must be equipped with intrinsically safe high level alarm and a tank overfill alarm. The tank overfill alarm must be independent of the cargo gauging system. Both high level alarm and overfill alarms are inoperable on cargo tanks; 2 port and starboard, and 8 port and starboard. Vessel not permitted to load in the tanks listed above until repaired or replaced. 46 CFR 39.2007 - 50 c.
Action required: 705 - Other - as specified
Due 14 February 2018
Resolved 17 January 2019
Resolution: Documentation proiveded by Vessel Rep

Ownership record