MAURY USCG vessel records
← All vessels

ASPHALT SYNERGY

ASPHALT SYNERGY is a 2018 tank ship. The Coast Guard has recorded 14 inspections since 2018, most recently in August 2026, along with 3 deficiencies and 4 operational controls.

Records from 2018 to 2026. Most recent: inspection, 4 August 2026.

Built
2018
Last inspected
4 August 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 4 August 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2018–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9794159
1481945
Flag
MARSHALL ISLANDS
Maury page id
psix-1481945

Documentation record

Tonnage as PSIX records it48385 - Displacement, Metric Ton
26118 - Convention (Subpart B), Gross Ton
36771 - Dead Weight, Metric Ton
7835 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

14 inspections, each with its date, unit and type; 3 deficiencies with the resolution recorded against each; 4 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 14

4 August 2026 COE-Administrative
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8455090
26 June 2026 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8417373
22 June 2026 COE-Administrative
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8410291
14 May 2026 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8373399
13 April 2026 COE-Administrative · COC-TVE Renew · PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8346125
3 January 2025 COC-TVE Renew · PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8057074
10 January 2024 PSC B · COC-TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7847485
24 December 2022 COC-TVE Renew · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7610011
27 August 2021 Ballast Water Examination · COC-TVE Annual · MARPOL Annex VI Survey · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7297976
10 August 2020 PSC B · COC-TVE Renew
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7029259
8 May 2020 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6950329
27 May 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6695692
27 March 2019 COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6650109
31 March 2018 ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6378655

Deficiency record · 3

14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 27 March 2019 Resolved
The arrangement on board the ship for the extraction of samples from the 15PPM bildge alarm should give a truly representative sample of the effluent with adequate pressure and flow. PSCO observed a vavle installed in the sample extraction line.... PSCO believes the installed valve in the sample line can prevent the OCM from receiving a truly representative sample of the effluent. MARPOL 73/78 Annex I/14.7; MEPC 107(49) 6.2.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 March 2019
Resolution: Received, reviewed and approved LR class report indicating that sampling line valve was removed and piping diagrams have been updated. OCM is installed to give an alarm if sample flow is interrupted.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 27 March 2019 Resolved
The company should establish procedures, plans, and instructions, including checklists as appropriate for key shipboard operations concerning protection of the environment. Due to PSCO's observations, an audit of the vessel's SMS by the.... is recommended to be completed within 30 days... 74SOLAS(2014)IX/3.1; ISM code A/12.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2019
Resolved 29 March 2019
Resolution: Received, reviewed and accepted LR class report. Audit has been carried out successfully.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 27 March 2019 Resolved
Each operation described in paragraph 2 of this regulation shall be fully recorded without delay in the Oil Record Book Part I, so that all entries in the book appropriate to that operation are completed. An entry made on 12FEB19 did not list al components of the item to be recorded. The code 'D' did not list item 15. MARPOL 73/78 Annex I/17.4
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2019
Resolved 29 March 2019
Resolution: Received, reviewed and accepted LR class report. ORB has been reviewed and the specified entry item has been corrected to indicate a discharge through 15ppm equipment on 12FEB19.

Ownership record