MAURY USCG vessel records
← All vessels

ROCHESTER PEDAL TOURS

ROCHESTER PEDAL TOURS is a 2017 passenger vessel (inspected). The Coast Guard has recorded 11 inspections since 2017, most recently in July 2025, along with 16 deficiencies.

Records from 2017 to 2025. Most recent: inspection, 9 July 2025.

Built
2017
Last inspected
9 July 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 9 July 2025
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2017–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

1482820
Flag
UNITED STATES
Maury page id
psix-1482820

Documentation record

Tonnage as PSIX records it3 - Simplified, Net Ton
3 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 11

9 July 2025 Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8180795
27 June 2024 Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7946354
28 July 2022 Administrative Inspection · Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7511110
21 October 2021 Drydock Exam
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7337736
14 July 2021 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7253727
22 July 2020 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7014077
5 December 2019 Drydock Exam · Damage Survey · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6868047
17 June 2019 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6716808
6 June 2018 Simplified Stability Test
Physical examination · Marine Safety Center (MSC) · Activity 6437245
5 March 2018 Plan Review "T" Boat · Initial Certification · Construction Oversight · DAPI Audit · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6367752
12 December 2017 Construction Oversight · Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6323533

Deficiency record · 16

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 July 2025 Resolved
Original Certificate of Inspection was not on board.
Action required: 10 - Deficiency Rectified
Resolved 9 July 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 July 2025 Resolved
Floating water light battery was found to be expired. Replace floating water light battery. Prior to nighttime operations.
Action required: 705 - Other - as specified
Resolved 22 July 2025
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 27 June 2024 Resolved
Expired burn oinment was found in the first aid kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2024
Resolved 16 July 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 June 2024 Resolved
Life ring was not marked with the name of the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2024
Resolved 5 July 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 July 2022 Resolved
Life ring was not marked as required with vessel name. Mark the life ring as required.
Action required: 10 - Deficiency Rectified
Resolved 28 July 2022
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 28 July 2022 Resolved
Aspirin was not available in the first aid kit. Update first aid kit to provide aspirin.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 August 2022
Resolved 24 August 2022
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 28 July 2022 Resolved
Emergency portable lights were not operable. Repair/replace portable emergency lights.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 August 2022
Resolved 24 August 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 14 July 2021 Resolved
Vessel was due for local OCMI required annual dry dock on 31 DEC 2020. Schedule and complete dry dock prior to storage for the winter of 2021.
Action required: 705 - Other - as specified
Resolved 21 October 2021
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 14 July 2021 Resolved
Stability letter was not posted. Post stability letter on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2021
Resolved 21 July 2021
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 14 July 2021 Resolved
MIS Report was not made available. Provide copy of previously submitted MIS Report for drug testing requirements.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 August 2021
Resolved 21 July 2021
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 14 July 2021 Resolved
Required medications were not available in the first aid kit. Provide aspirin as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 August 2021
Resolved 21 July 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 July 2021 Resolved
Port side navigation light lens was missing. Repair/replace port side navigation light. Light was operable and was a red LED. Only the lens was missing
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2021
Resolved 22 July 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 July 2020 Resolved
Failed to have sufficient number of alcohol test strips readily available on board. Provide non expired alcohol test strips within 14 days.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2020
Resolved 4 August 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 July 2020 Resolved
Medications in first aid kit must not be expired
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2020
Resolved 4 August 2020
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 July 2019 Resolved
Waste receptacles must be constructed of non-combustible materials with no openings in the sides or bottom. The vessel currently plastic trash can on board. Either remove or replace with appropriate receptacles with in 14 days.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 25 July 2019
Resolution: Vessel owner placed a new metal can on board the vessel.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 16 July 2019 Resolved
The stability letter must be posted under glass or other suitable transparent material with all pages visible. The stability letter is not currently posted. Correct within 14 days.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 25 July 2019
Resolution: The vessel posted the stability letter on board the vessel.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.