NORDPACIFIC is a freight ship. The Coast Guard has recorded 15 inspections since 2018, most recently in February 2025, along with 1 deficiency and 6 operational controls.
Records from 2018 to 2025. Most recent: inspection, 1 February 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it28433 - Simplified, Gross Ton 12607 - Simplified, Net Ton 35066 - Dead Weight, Ton 28433 - Convention (Subpart B), Gross Ton 12607 - Convention (Subpart B), Net Ton 47486 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 15
1 February 2025PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8073097
24 July 2023PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7750753
20 January 2023Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7624511
26 August 2022Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7543966
28 November 2021PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7358054
20 November 2021Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7354794
15 August 2020Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7033503
20 May 2020Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6956451
17 May 2020PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6954668
14 May 2020Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6953063
17 April 2020Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6940394
16 January 2020Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6890808
9 September 2019ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6807185
5 July 2019Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6745751
10 September 2018Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6536735
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 September 2019Resolved
The machinery, boilers and other pressure vessel, associted piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. Main engine air cooling drain tank has separate oil content meter and 3-way valve system installed, 3-way valve did not close as intended when oil content meter alarmed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2019
Resolved 16 January 2020
Resolution: PSCO attended vessel. Ship’s crew replaced solenoid valve on tree way valve. PSCO conducted satisfactory test, witnessing PPM alarm and valve closing
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.