Records from 2017 to 2026. Most recent: inspection, 29 April 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 25
29 April 2026
Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8358320
16 January 2026
Administrative Inspection
Administrative · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8297613
9 October 2025
Drydock Exam · Administrative Inspection · In-Service Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8250307
5 November 2024
Deficiency Check · Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8031147
11 September 2024
Damage Survey
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8001076
11 September 2024
Type not recorded
No type recorded · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8020192
8 February 2024
Administrative Inspection
Administrative · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 7948374
30 January 2024
COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7857652
17 October 2023
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7810221
1 February 2023
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7630136
31 August 2022
In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7547398
27 January 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7386358
12 October 2021
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7346038
27 July 2021
In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7268980
16 February 2021
DAPI Audit · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7146642
27 January 2021
Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7131243
3 December 2020
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7107108
17 July 2020
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7008908
13 February 2020
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6925755
9 January 2020
Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6886151
22 August 2019
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6792144
1 August 2019
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6769997
4 June 2019
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6702906
8 May 2019
In-Service Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6679677
27 July 2017
Construction Oversight · Initial Certification
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6616804
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 November 2024
Resolved
A vessel must comply with the applicable requirements for any radio installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. FCC Safety Radio certificate expired. Requires renewal. 46 CFR 184.502
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 November 2024
Resolved 15 November 2024
Resolution: New FCC safety radio cert installed on vessel
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 5 November 2024
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. Port and Starboard engines require guards over exposed engine drive belts. 46 CFR 177.960
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 December 2024
Resolved 22 November 2024
Resolution: Engine drive belt guards installed port and starboard
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 5 November 2024
Resolved
At each inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the inspection and operation of all watertight closures in decks. Port and starboard steering hatch strut support rods missing. Both require repair or replacement. 46 CFR 176.802(a)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 December 2024
Resolved 15 November 2024
Resolution: New struts on port and starboard steering compartment hatch installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 November 2024
Resolved
The owner shall submit the following plans,that are applicable to the vessel as determined by the OCMI: On sailing vessels:
(i) Masts, including integration into the ship's structure; and
(ii) Rigging plan showing sail areas and centers of effort as well as the arrangement, dimensions, and connections of the standing rigging. Provide updated 2024 Rigging PMP and sail plan for vessel. 46 CFR 177.202(b)(12)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 December 2024
Resolved 15 November 2024
Resolution: Updated PMP installed on vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 5 November 2024
Resolved
A vessel on an oceans, coastwise, or limited coastwise route must carry (1)Six hand red flare distress signals approved in accordance with § 160.021 in subchapter Q and(2)Six hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter. Vessels distress signals found expired, renewed during inspection. 46 CFR 180.68(a)(1)(2)
Action required: 10 - Deficiency Rectified
Due 5 November 2024
Resolved 5 November 2024
Resolution: New flares provided.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 September 2024
Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Port side fresh water tank leaking requires replacement. Both port and starboard fiberglass supports damaged during marine casualty. Both require replacement. 46 CFR 176.840
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 September 2024
Resolution: Fresh water tanks support tabs reglassed. Water tank secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 30 January 2024
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Ventilation closure for starboard engine room did not close when operated. Provide operational starboard engine room ventilation closure.
46 CFR 182.465(h)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 January 2024
Resolution: Vent closure operational.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 January 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Area where house batteries and wiring located had water on deck. Water leak could not be traced. Find water leak and secure leak.
46 CFR 183.200
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 February 2024
Resolved 13 June 2024
Resolution: Water was soaked up and never came back. No leak found.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 30 January 2024
Resolved
All fiber reinforced plastic vessels constructed with general purpose resins must be fitted with a smoke activated fire detection system of an approved type installed in accordance with 76.27 in subchapter H of this chapter in accommodation spaces and service spaces. Vessel does not a have smoke activated fire detection system for required spaces. Provide smoke activated fire detection system and install to the satisfaction of the attending marine inspector.
46 CFR 177.410(c)(3)(ii)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 February 2024
Resolved 9 August 2024
Resolution: Special Consideration was approved for smoke detectors.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 February 2023
Resolved
The owner shall be prepared to conduct tests and have the vessel ready for inspection of the following: On a sailing vessel all spars, standing rigging, running rigging, blocks, fittings, and sails. Vessel did not conduct 6 month furler disassembly in accordance with company policy located in the Preventative Maintenance Plan. Complete inspection of rigging by disassembling the furler and conducting inspection in accordance with company issued PMP.
46 CFR 176.802 (a)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2023
Resolved 11 February 2023
Resolution: Rigging inspection completed.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 1 February 2023
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2023
Resolved 1 March 2023
Resolution: Charts and pubs provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 January 2022
Resolved
Fuel shutoff must be manually operable from outside the compartment in which the valve is located. Starboard side fuel shut off not operational. Provide operational starboard side fuel shutoff.
46 CFR 182.455
Action required: 10 - Deficiency Rectified
Resolved 27 January 2022
Resolution: Stbd fuel shutoff repaired and operational.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 27 January 2022
Resolved
Life float float-free (weak) link must be of proper strength for the size of life float as indicated on its identification tag. Current float-free link was rated for more buoyancy than the life float can provide rendering the float-free link non-operational. Provide proper strength float-free link for life floats.
46 CFR 180.137
Action required: 10 - Deficiency Rectified
Resolved 27 January 2022
Resolution: Both Life Floats daisy chained together and connected to 01 weak link until proper size weak links purchased for each float.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 27 January 2022
Resolved
Vessel must have on board the original Certificate of Documentation currently in effect for that vessel. Valid COD not on vessel. Provide valid and original COD.
46 CFR 67.313
Action required: 10 - Deficiency Rectified
Resolved 27 January 2022
Resolution: COD Provided.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 27 January 2022
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2022
Resolved 1 February 2022
Resolution: Nav pubs provided.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 January 2022
Resolved
Flammable materiel must be stowed in proper insulted locker. Flammable items in starboard storage. Provide paint locker or remove flammable materials from vessel.
46 CFR 183.530
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2022
Resolved 17 February 2022
Resolution: Flammables removed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 27 January 2022
Resolved
A hatch exposed to weather must be watertight. Forward port side hatch cracked/broken. Replace with new hatch.
46 CFR 179.360
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2022
Resolved 28 March 2022
Resolution: New hatch installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 27 January 2022
Resolved
Gauges to indicated RPM, jacket water temp, and lube oil pressure must be provided and readily visible at operating station. Port side gauges not operational. Provide operational port side gauges.
46 CFR 182.410
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2022
Resolved 28 March 2022
Resolution: Gauges operational.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 January 2022
Resolved
Furler required to be disassembled for wire, fitting inspection every 6 months in accordance to PMP. No log to show when furler was last disassembled in the past year. Disassemble furler and conduct inspection on rigging components.
Company owned Sail Rigging PMP
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2022
Resolved 18 February 2022
Resolution: Furler disassembled and inspected.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 January 2022
Resolved
Boom must be suitable for the intended service. 03 cracks located on aluminum boom at goose-neck/fwd where reefing block is located. Provide repair proposal and conduct repair to cracked areas.
46 CFR 177.330
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2022
Resolved 18 February 2022
Resolution: Boom cracks verified by builder, [name withheld], and captian to not be structural.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 February 2021
Resolved
Update Company Drug Policy/Paperwork to reflect current changes to DAPI program (i.e., Provide EAP information; SAP information; Hot-line information, etc).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 March 2021
Resolved 15 March 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 February 2021
Resolved
The Designated Employee Representative (DER) should be executing the notification process to employees for completion of DOT Random Drug Tests.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 March 2021
Resolved 8 March 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 February 2021
Resolved
Establish record system as discussed during DAPI Audit. Provide MIS reports for 2016 and 2018. Ensure record system is secured and organized in DER office.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 March 2021
Resolved 8 March 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 February 2021
Resolved
Provide Letter of Regulatory Compliance (LORC) for Reliable Drug Testing Services Consortium.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 March 2021
Resolved 8 March 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 February 2021
Resolved
An EAP training program must be conducted for the employer's crewmembers and supervisory personnel. The training program must include at least the following elements: the effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crewmembers and the employer's supervisory personnel. Supervisory personnel must receive at least 60 minutes of training. Provide proof of completed EAP training for all personnel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 March 2021
Resolved 15 March 2021
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 27 January 2021
Resolved
Navigation items missing included chart, current light list, Coast Pilot [name withheld], and Nav Rules. Provide all local chart and navigation publications.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2021
Resolved 9 February 2021
Resolution: Nautical Pubs Provided
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 January 2021
Resolved
FCC Safety Radio Certificate not issued/onboard/available. Provide valid FCC Radio Safety Certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2021
Resolved 8 February 2021
Resolution: FCC Safety Radio Cert Provided
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 January 2021
Resolved
Numerous flammable materials located in Starboard storage area(solvents, spay cans, butane). Remove flammable material or provide Flammable Locker for storage.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 January 2021
Resolution: Flammable materials removed.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 27 January 2021
Resolved
Both gray water and black water valves open on MSD Type III holding tanks. Keep valves closed within 3 miles from land and provide locking mechanism when within 3 miles from land.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2021
Resolved 15 February 2021
Resolution: Locks installed on MSD.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 January 2021
Resolved
Gasoline powered portable generator was located in lazarette/steering space. Remove portable generator.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 February 2021
Resolved 28 January 2021
Resolution: Portable generator removed.
09 - Working and Living Conditions › 092 - Working Conditions › Other (working space ILO)
Issued 27 January 2021
Resolved
VHF Emergency broadcast placard missing. Provide Emergency Broadcast placard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2021
Resolved 30 January 2021
Resolution: Emergency Broadcast Placard provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 January 2021
Resolved
Complete Sail Rigging Preventative Maintenance Plan (PMP) not onboard. PMP should specifically addresses their vessel’s sail rigging equipment and components. A PMP, should include general description, exam and maintenance schedule, and inventory of rigging components. This should be a living document that can be changed as needed. Provide updated PMP for vessel and provide copy to [name withheld].
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2021
Resolved 8 February 2021
Resolution: PMP submitted
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 27 January 2021
Resolved
Stern navigation light covered by fabric grill cover. Alter or remove grill cover so stern navigation light visible.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 January 2021
Resolution: Grill cover removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 January 2021
Resolved
Diesel fuel tank vent missing 30x30 flame screen or flame arrester. Provide 30x30 or flame arrester for diesel fuel vent.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2021
Resolved 23 February 2021
Resolution: New 30x30 mesh installed on fuel vents.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 January 2020
Resolved
Stbd rudder compartment bilge pump failed to operate. Repair/renew in accordance with 46 CFR 176.804.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 January 2020
Resolved 17 July 2020
Resolution: Bilge pump satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 January 2020
Resolved
Extension cord was present in galley storage for camera system. Remove cord in accordance with 46 CFR 183.220.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 February 2020
Resolved 17 July 2020
Resolution: Extension cord removed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 January 2020
Resolved
Rigging Preventative Maintenance Plan was not provided. Provide in accordance with 46 CFR 176.840.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 February 2020
Resolved 17 July 2020
Resolution: Rigging Preventative Maintenance Plan provided.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 30 January 2019
Resolved
Provide proof of Master's License. 46 CFR 185.402
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2019
Resolved 8 May 2019
Resolution: Master provided current suitable license.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 January 2019
Resolved
Provide alcohol/drug testing supplies. 46 CFR 185.212 and 46 CFR 4.06-15
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2019
Resolved 28 May 2019
Resolution: Alcohol testing devices provided.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 30 January 2019
Resolved
Once the stability calculations are completed and returned from MSC, Post/Provide Stability Letter on the Vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2019
Resolved 8 May 2019
Resolution: Current stability letter provided onboard.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 30 January 2019
Resolved
Conduct Drills as required by the attending Marine Inspector during new to Zone exam. 46 CFR 185.520/524
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2019
Resolved 8 May 2019
Resolution: Satisfactory Man overboard and Firefighting drills conducted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 January 2019
Resolved
Prove compliance with NVIC 02-16 INSPECTION GUIDANCE FOR SAIL RIGGING AND MASTS ON INSPECTED SAILING VESSELS to the satisfaction of Attending Marine Inspector. (NVIC 02-16)
Action required: 705 - Other - as specified
Due 28 February 2019
Resolved 16 May 2019
Resolution: Satisfactory Sail/Rig Report recieved from Tradewinds marine services.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 30 January 2019
Resolved
Provide Certificate of Documentation (46 CFR 67.7)
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2019
Resolved 8 May 2019
Resolution: Current COD provided onboard.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 January 2019
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2019
Resolved 28 May 2019
Resolution: FCC Station license and radio operators permit provided.