Records from 2018 to 2026. Most recent: inspection, 26 May 2026.
Inspection history · 14
26 May 2026
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8405594
21 April 2025
Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8117729
28 March 2025
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8101247
13 June 2024
COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7942374
10 January 2024
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7847749
3 April 2023
Drydock Exam · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7662151
14 November 2022
Administrative Inspection · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7594397
9 December 2021
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7364987
25 March 2021
Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7162875
19 November 2020
COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7101460
1 August 2019
COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6753598
18 July 2019
Plan Review "T" Boat · Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6754451
8 May 2019
Simplified Stability Test
Physical examination · Marine Safety Center (MSC) · Activity 6710259
3 January 2018
Plan Review "T" Boat · Construction Oversight
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6333135
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 28 March 2025
Resolved
A vessel on a lakes, bays, and sounds must carry three hand red flare distress signals and three hand orange smoke signals. A red hand flare distress signal may be substituted for any of the hand orange smoke distress signals. Vessel's was missing 01 hand orange smoke distress signal. Get on more orange flare and notify local OCMI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2025
Resolved 28 March 2025
Resolution: Received photo of new flares. All SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 March 2025
Resolved
Vessel required to have one 24" ring lifebuoy fitted with 60' lifeline and floating water light attached with a corrosion resistant clip to allow quick disconnect. Ring lifebuoy lifeline was found deteriorated. Provide serviceable ring lifebuoy onboard vessel and properly arranged.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2025
Resolved 28 March 2025
Resolution: Received photo of new lifebuoy. All SAT.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 April 2023
Resolved
Vessel found to be past due for hull/Internal structure examination. Complete Coast Guard Hull/Internal structure exam.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 April 2023
Resolution: Completed satisfactory DDX.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 14 November 2022
Resolved
Vessel is past due for its Annual Inspection. Complete a satisfactory USCG COI Annual Inspection of the vessel with a USCG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 November 2022
Resolution: COMPLETED ANNUAL
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 December 2021
Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: (1) Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10 (incorporated by reference, see § 175.600 of this chapter.)Portable fire extinguishers found to have not been inspected within the last year. Extinguishers should be properly inspected by an approved servicing facility, or replaced.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 December 2021
Resolution: Portable fire extinguishers serviced by Global Fire.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 December 2021
Resolved
Annual inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel failed to have an annual inspection when required.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 9 December 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 December 2021
Resolved
Fuel tanks must be adequately supported and braced to prevent movement. Fuel tank found to be missing bolts allowing for movement of the tank and the tank ventilation louver. Hardware should be replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2021
Resolved 9 December 2021
Resolution: Added bolts to Fuel Tank and ventallation louver to prevent movement.