Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it81361 - Convention (Subpart B), Gross Ton 159055 - Dead Weight, Ton 52258 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page
2 inspections, each with its date, unit and type; 3 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
PlansSign in
Maury does not score, rate or grade vessels, at any price.
Vessel history report
A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 2
19 February 2025Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8081427
23 October 2024COC-TVE Renew · COE-Administrative · PSC A
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8023438
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 1 November 2024Resolved
For tankers...fire doors in main vertical zone and galley boundaries shall be self-closing. PSCE observed self-closing door to reefer space access held back by lanyard and missing self-closing device. 74 SOLAS (20) II-2/9.4.1.1.5.1
Action required: 10 - Deficiency Rectified
Resolved 1 November 2024
Resolution: The lanyard was removed to allow the door to operate as designed.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 1 November 2024Resolved
For tankers...fire doors in main vertical zone and galley boundaries...hold back hook not subject to central control station release are prohibited. PSCE observed hold back on door to provision store access from galley at top of store landing.
Action required: 10 - Deficiency Rectified
Resolved 1 November 2024
Resolution: The holdback device was removed for the door to operate as intended.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 1 November 2024Resolved
The ring, line and letters shall be painted in white or yellow on a dark ground or in black on a light ground. PSCE observed load line marking missing contrasting paint.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 February 2025
Resolution: Received class survey report attesting to the deficiency rectified to the satisfaction of the attending surveyor.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.