This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)200.0 ft × 35.0 ft × 12.5 ft
Registered tonnagegross 735 / net 735
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJEFFBOAT LLC · JEFFERSONVILLE, IN, UNITED STATES · built 2018
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portST LOUIS, MO
Endorsements, as the file codes themcw_un
DocumentationValid · issued 29 April 2026 · expires 31 May 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it735 - Simplified, Gross Ton 735 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 6 inspections, each with its date, unit and type; 6 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 6
12 July 2023Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7740793
26 June 2023Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7724300
16 March 2023COI Inspection · MTSA Verification · Internal Structural Exam · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7652191
17 May 2019Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6686686
25 April 2019MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6670571
8 December 2017Internal Structural Exam · MTSA Verification · Construction Oversight · Administrative Inspection · Hull Examination · Initial Certification · Cargo Tank Internal
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6370366
You must submit a written application for an inspection for certification to the cognizant OCMI. To renew a Certificate of Inspection, you must submit an application at least 30 days before the expiration of the tank vessel's current Certificate of Inspection. When renewing a Certificate of Inspection, you must schedule an inspection for certification within the 3 months before the expiration date of the current Certificate of Inspection. Vessel Rep scheduled COI renewal two days before the anniversary date.
46 CFR 31.01-15(a)
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 17 March 2023
Resolved 17 March 2023
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 16 March 2023Resolved
Cargo pump relief valves shall be tested at least once each year to determine that they function satisfactorily at the pressure at which they are set to open. Cargo pump relief valves shall be serviced prior to loading of cargo.
46 CFR 35.35-70(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 March 2023
Resolved 24 April 2023
Resolution: Cleared to the satisfactory of the Marine Inspector.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 16 March 2023Resolved
Cargo pump pressure gage shall be tested at least once a year for accuracy. Cargo pump pressure gage shall be serviced prior to loading of cargo.
46 CFR 35.35-70(c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 March 2023
Resolved 24 April 2023
Resolution: Cleared to the satisfactory of the Marine Inspector.
On all tank barges, subject to the provisions of this subchapter the construction or conversion of which is started on or after July 1, 1951, each cargo tank shall be equipped with a vent. Due to cargo on board the vessel during inspection, mast riser was not lowered to have the flame screen inspected. Mast riser must be inspected to the satisfaction of CG MI prior to loading of cargo.
46 CFR 35.35-70(c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 March 2023
Resolved 24 April 2023
Resolution: Cleared to the satisfactory of the Marine Inspector.
The inspection for certification shall include an inspection of the structure, boilers, and other pressure vessels, machinery and equipment. Vessel must show proof to the satisfaction of CG MI that P/V valve has been serviced IAW manufacturer's instructions prior to loading of cargo.
46 CFR 31.10-15(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 March 2023
Resolved 24 April 2023
Resolution: Cleared to the satisfactory of the Marine Inspector.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 25 April 2019Resolved
Vessel must display Cargo name and have cargo information card displayed when carrying subchapter O cargo. Barge was loaded with Styrene. Install proper signs and CIC.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 25 April 2019
Resolved 25 April 2019
Resolution: Barge rep installed signs and CIC.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National