MAURY USCG vessel records
← All vessels

GOVERNORS 1

GOVERNORS 1 is a 2019 passenger vessel (inspected). The Coast Guard has recorded 18 inspections since 2017, most recently in January 2026, along with 16 deficiencies and 2 operational controls, 1 with no removal date recorded.

Records from 2017 to 2026. Most recent: inspection, 8 January 2026.

Built
2019
Last inspected
8 January 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
1 with no removal date recorded

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 8 January 2026
Operational controls 1 with no removal date recorded
Years with a record 9 calendar years (2017–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDN7710
1484373
Flag
UNITED STATES
Maury page id
psix-1484373

Documentation record

Registered dimensions (L × B × D)126.4 ft × 39.9 ft × 13.0 ft
Registered tonnagegross 96 / net 65
ITC dimensions (L × B × D)126.4 ft × 39.9 ft × 13.0 ft
ITC tonnagegross 550 / net 190
BuilderBLOUNT BOATS INC · WARREN, RI, UNITED STATES · built 2019
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 28 July 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it550 - Convention (Subpart B), Gross Ton
96 - Regulatory (Subpart C or D), Gross Ton
190 - Convention (Subpart B), Net Ton
65 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 18

8 January 2026 Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8291929
7 May 2025 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8130144
19 February 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8081259
6 May 2024 Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7907605
30 August 2023 Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7780966
24 May 2023 Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7695745
1 May 2023 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7678835
11 April 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7666619
6 February 2023 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7602478
22 December 2022 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7613192
12 December 2022 Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7607900
3 August 2022 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7523725
8 June 2021 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7219181
22 April 2021 Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7180527
9 June 2020 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6972100
1 November 2019 Deficiency Check · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6847323
29 May 2019 Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6698307
7 October 2017 Initial Construction-Excluding Oversight · Initial Certification
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6676603

Deficiency record · 16

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 April 2026 Resolved
Replace raw water cooling line on #1 side MDE. Temp. repairs are authorized.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2026
Resolved 13 May 2026
Resolution: Rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 May 2024 Resolved
46 CFR 119.200 (b) All engines must have at least two means for stopping the engine(s) under any operating conditions. The fuel oil shutoff required at the engine by § 119.455(b)(3) of this part will satisfy one means of stopping the engine. 46 CFR 119.455 (b)(3) Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. If the handle to the shutoff valve at the tank is located inside the tank compartment, it must be located so that the operator does not have to reach more than 300 millimeters (12 inches) into the compartment and the valve handle must be shielded from flames by the same material the hull is constructed of, or some noncombustible material. Electric solenoid valves must not be used, unless used in addition to the manual valve. Remote Fuel Shutoff Valve, cable & valve arrangement, did not demonstrate valve closure satisfactorily.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2024
Resolved 10 June 2024
Resolution: 10June2024: Received and accepted email proof (video) of repairs/modifications made to the Remote Fuel Shutoff Valve, cable & valve arrangement (CG835-Item 1, 50c).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 May 2024 Resolved
46 CFR 121.620 All microprocessor or computer based systems must meet the requirements of part 62 in subchapter F of this chapter. 46 CFR 61.40-1 (a) All automatically or remotely controlled or monitored vital systems addressed by part 62 of this subchapter must be subjected to tests and inspections to evaluate the operation and reliability of controls, alarms, safety features, and interlocks. Test procedures must be submitted to the Coast Guard for approval.(b) Persons designated by the owner of the vessel shall conduct all tests and the Design Verification and Periodic Safety tests shall be witnessed by the Coast Guard.(c) Design Verification and Periodic Safety test procedure documents approved by the Coast Guard must be retained aboard the vessel. Several items/steps in the PSTP's did not produced designed results.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2024
Resolved 1 August 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 May 2024 Resolved
46 CFR 115.814 At each initial and subsequent inspection for certification the owner or managing operator shall be prepared to test the steering systems of the vessel and make them available for inspection to the extent necessary to determine that they are in suitable condition and fit for the service intended. Servo-type power systems, such as orbital systems, must be tested and capable of SMOOTH OPERATION BY A SINGLE PERSON in the manual mode, with hydraulic pumps secured. Emergency steering instructions were not satisfactorily posted.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2024
Resolved 29 May 2024
Resolution: Received and accepted email proof of Steering Instructions.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 15 May 2024 Resolved
On vessel of more than 65 ft in lenght, th epublic address system must be fixed installation and be audible during normal operations throughtout the accomidation space and all other spaces normally manned by crew members. The public address system while in ALL MODE does not sound in all spaces as intended. 46 CFR 121.610 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2024
Resolved 1 August 2024
Resolution: Recieved service report for the repairs performed on the Governors 1 regarding the PA / Loudhailer System.
04 - Emergency Systems › N/A - No Subsystem › Safe areas
Issued 15 May 2024 Resolved
The fire control plan must show escape routes, areas of refuge, embarkation stations... The fire control plan did not show areas of refuge, plan needs to be updated. 46 CFR 116.530
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2024
Resolved 29 May 2024
Resolution: Received and accepted email proof of Emergency Egress Instructions
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 6 May 2024 Resolved
Complete but simple instructions for the operation of a fixed gas fire extinguishing system must be located in a conspicuous place at or near each pull box and stop valve control and in the space where the extinguishing agent cylinders are stored. Also include a schematic diagram of the system and instructions detailing alternate methods of releasing the extinguishing agent... The fixed fire extinguishing system diagram and operating procedures need to be at the pull location.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2024
Resolved 29 May 2024
Resolution: Received and accepted email proof of the NOVEC Fire Suppression System Instructions.
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 1 May 2023 Resolved
The certificate of inspection (COI)issued by an Officer in Charge, Marine Inspection (OCMI), to a vessel required to be inspected under 46 U.S.C. 3301 specifies the minimum complement of officers and crew necessary for the safe operation of the vessel. The COI of subject vessel states "A COPY OF THE DESIGNATION LETTER SHALL BE MAINTAINED ON BOARD THIS VESSEL." There is no letter on-board. A copy of the letter was provided and is place on-board Item cleared.
Action required: 10 - Deficiency Rectified
Due 1 May 2023
Resolved 1 May 2023
Resolution: A copy of the letter was provided and is place on-board Item cleared.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 12 December 2022 Resolved
The owner, charterer, master, or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as tot he duties that the crew member is expected to perform in an emergency including, but not limited to, the emergency instructions listed on teh emergency instruction placard required by 122.510, when applicable, the duties listed int eh station bill required by 122.514. Crew unable to identify void/space in which a bilge alarm sounded. Additionally, crew was not knowledgeable in operation of vessel's bilge system. Vessel's crew must express competence in emergency situations in the presence of CG Marine Inspector prior to vessel's movement.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2022
Resolved 14 December 2022
Resolution: Crew was trained and showed how to use systems with MI
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 12 December 2022 Resolved
Each hatch exposed to the weather must be watertight, hatches leading to void#2 and lazarette #2 are leaking and causing the high level water alarm to go off.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2022
Resolved 14 December 2022
Resolution: New gaskets installed and dogs adjusted, checked water tightness with hose.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 August 2022 Resolved
MI observed potable water connection located in an area with unrestricted access.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2022
Resolved 3 August 2022
Resolution: Operator submitted satisfactory photographs of potable water fills locked (see deficiencies documents tab for photos).
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 3 August 2022 Resolved
Vsl bilge alarm located in the lazarette was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2022
Resolved 3 August 2022
Resolution: Operator submitted satisfactory photographs of lazarette high water operable (see deficiencies documents tab for photos).
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 8 June 2021 Resolved
Vessel Drug and Alcohol Program (DAPI) documentation was not onboard. No Employee Assistance Program (EAP) phone numbers were posted. Ensure all DAPI documentation is onboard, and post EAP number on pilothouse and in crew lounge.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 June 2021
Resolution: Cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 June 2020 Resolved
the fuel shut off valve at the tank must be manually operable from outside the compartment in which the valve is located. fuel shut off valve for engines on no 1 & 2 were not able to be operated utilizing fuel stops. 46 CFR 119 (b)(3)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 June 2020
Resolution: Attending marine inspectors verified satisfactory repair.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 November 2019 Resolved
GOVERNORS I crew must perform man overboard drill to the satisfaction of the USCG attending MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 June 2020
Resolution: Attending MI witnesses satisfactory MO drill.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 May 2019 Resolved
Complete New To Zone Inspection prior to passenger operation.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 June 2019
Resolution: Inspection Complete.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.