GEMMA is a 2018 tank ship. The Coast Guard has recorded 5 inspections since 2021, most recently in November 2025, along with 2 deficiencies and 1 operational control.
Records from 2021 to 2025. Most recent: inspection, 15 November 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it26548 - Regulatory (Subpart C or D), Gross Ton 10096 - Regulatory (Subpart C or D), Net Ton 26548 - Convention (Subpart B), Gross Ton 10096 - Convention (Subpart B), Net Ton 40019 - Dead Weight, Metric Ton 49894 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 5
15 November 2025PSC B · COC-CHEM & TVE Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8264100
14 November 2025Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8268408
13 March 2024COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7878497
3 October 2023COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7798734
11 March 2021PSC A · COC-CHEM & TVE Renew
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7154035
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 11 March 2021Resolved
11102 - The normal equipment of every lifeboat shall consist of a food ration for every person tthe lifeboat is permitted to accommodate. The port side lifeboat is only carrying 29 of 30 required airtight food rations.
74SOLAS(14)III/34
LSA 4.4.8.9
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2021
Resolved 19 March 2021
Resolution: Vessel recieved new food rations onboard to replace expired ones.
01117 - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present convention to ensure the ship will remain fit to proceed to sea without presenting a threat to the marine environment. While reviewing the oil record book(ORB), PSCO observed on at least 3 occasions 08DEC2020, 09NOV2020, and 22OCT2020 that the oily water separator exceeded the maximum throughput of the system, which is 2.5 cubic meters/hour, during use.
MARPOL ANNEX I/6.4.1
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2021
Resolved 19 March 2021
Resolution: Determinded a clerical error was made when issuing certificate, correct maximum throughput for OWS was 5 cubic meters/hour. New IOPP and Form B issued by Llyod's Register.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.