Records from 2018 to 2025. Most recent: inspection, 5 September 2025.
Inspection history · 13
5 September 2025
COC-CVE Annual · PSC A
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8228044
4 October 2024
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8014459
19 September 2024
PSC A · COC-CVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8000240
14 September 2024
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8016700
20 October 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7581052
12 October 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7575948
10 October 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7574612
7 September 2022
PSC A · COC-CVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7553638
19 September 2019
ISPS II Exam · COC-CVE Initial · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6814590
4 September 2019
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6803727
5 April 2018
COC-CVE Initial Prep
Type not classified · Activities Europe · Activity 6390870
13 February 2018
Administrative Inspection · COC-CVE Initial
Administrative · Activities Europe · Activity 6354221
4 January 2018
COC-CVE Initial Prep
Type not classified · Activities Europe · Activity 6361425
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 5 September 2025
Resolved
SUCH PENETRATIONS SHALL BE SUITABLY INSULATED BY EXTENSION OF THE INSULATION AT THE SAME LEVEL OF THE DIVISION. PSCOS OBSERVED MULTIPLE COMPROMISED BULKHEAD PENETRATIONS.
74 SOLAS (20) II-2/9.3.1
16AC
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2025
Resolved 12 September 2025
Resolution: FLAG SURVEY CONDUCTED
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 5 September 2025
Resolved
SPACES ARE CLASSIFIED ACCORDING TO THEIR FIRE RISK AS SHOWN IN CATEGORY (1) TO (14). PSCOS OBSERVED MORE THAN DAILY USE AMOUNTS OF FLAMMABLE LIQUIDS STORED INA FILE CABINET AND LOCKER WITHIN THE SALON STORAGE ROOM
74 SOLAS (20) II-2/9.2.2.3.2.2
10C
Action required: 10 - Deficiency Rectified
Resolved 8 September 2025
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 September 2024
Resolved
The construction of doors and door frames in A class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame equivalent to that of bulkheads in which the doors are situated. Garbage room door did not fully close due to excess paint and debris.
74 SOLAS (20) II-2/9.4.1.1.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 19 September 2024
Resolution: Rectified onboard
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 19 September 2024
Resolved
Escape doors from public spaces that are normally latched shall be fitted with a means of quick release. Such means shall consist of a door-latching mechanism incorporating a device that releases the latch upon the application of a force in the direction of escape flow. Kids Theater had a twist lock on the emergency escape door that did not release when handle was used with force in the direction of escape.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 19 September 2024
Resolution: Rectified onboard
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 9 September 2022
Resolved
Plans and booklets shall provide information regarding fire protection, fire detection, and fire extinction. PSCO noted escape ladder in vicinity of fire screen door number 5.1.1 was not indicated on fire control plan.
74 SOLAS 20 II-2/15.3.2
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2022
Resolved 17 September 2022
Resolution: An email was received that included a picture of the updated fire control plan which included the noted escape ladder. A surveyor of class stamped and approved of the change.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 9 September 2022
Resolved
There shall not be any doors along any designated escape route which require keys to unlock them when moving in the direction of escape. PSCO observed a locked fire door leading from an office space door 4.2.21
74 SOLAS 20 II-2/13.3.2.6
Action required: 10 - Deficiency Rectified
Due 9 September 2022
Resolved 9 September 2022
Resolution: PSCO observed door unlocked prior to departing vessel.