MEIN SCHIFF 1 is a passenger vessel (inspected). The Coast Guard has recorded 13 inspections since 2018, most recently in September 2025, along with 6 deficiencies.
Records from 2018 to 2025. Most recent: inspection, 5 September 2025.
The 13 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Share this recordDownload vessel cardDownload QRMaury, US Coast Guard vessel record for MEIN SCHIFF 1, retrieved 18 September 2026. mauryrecords.com/v/psix-1484537.html
Documentation record
Tonnage as PSIX records it111554 - Convention (Subpart B), Gross Ton 10373 - Dead Weight, Ton 56863 - Displacement, Ton 75476 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 13
5 September 2025COC-CVE Annual · PSC A
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8228044
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 5 September 2025Resolved
SUCH PENETRATIONS SHALL BE SUITABLY INSULATED BY EXTENSION OF THE INSULATION AT THE SAME LEVEL OF THE DIVISION. PSCOS OBSERVED MULTIPLE COMPROMISED BULKHEAD PENETRATIONS.
74 SOLAS (20) II-2/9.3.1
16AC
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2025
Resolved 12 September 2025
Resolution: FLAG SURVEY CONDUCTED
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 5 September 2025Resolved
SPACES ARE CLASSIFIED ACCORDING TO THEIR FIRE RISK AS SHOWN IN CATEGORY (1) TO (14). PSCOS OBSERVED MORE THAN DAILY USE AMOUNTS OF FLAMMABLE LIQUIDS STORED INA FILE CABINET AND LOCKER WITHIN THE SALON STORAGE ROOM
74 SOLAS (20) II-2/9.2.2.3.2.2
10C
Action required: 10 - Deficiency Rectified
Resolved 8 September 2025
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 September 2024Resolved
The construction of doors and door frames in A class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame equivalent to that of bulkheads in which the doors are situated. Garbage room door did not fully close due to excess paint and debris.
74 SOLAS (20) II-2/9.4.1.1.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 19 September 2024
Resolution: Rectified onboard
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 19 September 2024Resolved
Escape doors from public spaces that are normally latched shall be fitted with a means of quick release. Such means shall consist of a door-latching mechanism incorporating a device that releases the latch upon the application of a force in the direction of escape flow. Kids Theater had a twist lock on the emergency escape door that did not release when handle was used with force in the direction of escape.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 19 September 2024
Resolution: Rectified onboard
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 9 September 2022Resolved
Plans and booklets shall provide information regarding fire protection, fire detection, and fire extinction. PSCO noted escape ladder in vicinity of fire screen door number 5.1.1 was not indicated on fire control plan.
74 SOLAS 20 II-2/15.3.2
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2022
Resolved 17 September 2022
Resolution: An email was received that included a picture of the updated fire control plan which included the noted escape ladder. A surveyor of class stamped and approved of the change.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 9 September 2022Resolved
There shall not be any doors along any designated escape route which require keys to unlock them when moving in the direction of escape. PSCO observed a locked fire door leading from an office space door 4.2.21
74 SOLAS 20 II-2/13.3.2.6
Action required: 10 - Deficiency Rectified
Due 9 September 2022
Resolved 9 September 2022
Resolution: PSCO observed door unlocked prior to departing vessel.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.