COSCO SHIPPING ALPS is a 2018 freight ship. The Coast Guard has recorded 6 inspections since 2018, most recently in December 2024, along with 2 deficiencies.
Records from 2018 to 2024. Most recent: inspection, 11 December 2024.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it154300 - Convention (Subpart B), Gross Ton 84334 - Convention (Subpart B), Net Ton 153679 - Dead Weight, Metric Ton 201020 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 6
11 December 2024PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8046143
6 March 2024Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7875119
13 March 2023PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7650064
1 October 2021Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7324452
3 August 2021PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7275886
5 February 2018ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6349622
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 6 March 2024Resolved
Fire-Fighting systems and appliances shall be kept in good working order and readily available for immediate use. Vessel self reported via email that the alarm for the water mist fire extinguishing system is inoperable in the engine room. Vessel does not intend the make repairs while in the Port of Los Angeles - Long Beach and has been issued a flag dispensation letter expiring on 01May2024. 74 SOLAS (20) II-2/14 2.1.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 6 March 2024
Resolved 9 April 2024
Resolution: class survey report received.
THE MASTER, OWNER, OPERATOR, AGENT, OR PERSON IN CHARGE OF ANY VESSEL EQUIPPED WITH BALLAST WATER TANKS THAT OPERATES IN THE WATERS OF THE UNITED STATES MUST FOLLOW THESE PRACTICES: (f) REMOVE FOULING ORGANISMS FROM THE VESSEL'S HULL, PIPING, AND TANKS ON A REGULAR BASIS AND DISPOSE OF ANY REMOVED SUBSTANCES IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL REGULATIONS. PSCO OBSERVED MARINE GROWTH ON THE vESSEL'S HULL.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 September 2021
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.