Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it17232 - Convention (Subpart B), Gross Ton 5170 - Convention (Subpart B), Net Ton 16596 - Dead Weight, Metric Ton 26112 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 9
14 April 2026COC-GAS Annual · Administrative Inspection
An audible and visual alarm system to give a warning on both sides of the airlock should be provided to indicate if more than one door is moved from the closed position.
PSCO observed exterior air lock door audible and visual alarm did not function on port and starboard PSA room entrances.
Provide documentation from RO attesting to proper operation of the air lock alarms.
74 SOLAS (20) VII/ 11.1
IGC Code (93) 3.6.3
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 5 June 2024
Resolved 14 June 2024
Resolution: Recieved Class Report attesting to repairs and successful testing of airlock alarms.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 16 June 2023Resolved
Emergency shutdown valves in liquid piping should fully close under all service conditions within 30 s of actuation.
PSCO observed liquid line #2 on port side manifolds not shutting upon activation of ESD.
IGC Code 1993 5.6.4
10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 16 June 2023
Resolved 16 June 2023