Records from 2018 to 2026. Most recent: inspection, 12 February 2026.
Inspection history · 7
12 February 2026
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8309679
2 February 2024
Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7859970
10 August 2023
PSC B
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7760661
20 June 2021
PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7225351
5 March 2019
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6636561
27 November 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6587929
20 February 2018
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6355535
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 10 August 2023
Resolved
07126 - Oil accumulation in engine room - The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: means shall be provided to control leaks of flammable liquids. PSCO observed accumulated oil in multiple places to include the steering gear, service generators, underneath main diesel engine and main air compressor. 74SOLAS(20)II-2/4.1.1 - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 10 August 2023
Resolved 11 August 2023
Resolution: Received, reviewed and accepted class report from ClassNK stating the deficiency was rectified. Cleaned the places of oil accumulated. Checked and retightened pipe fittings and connectors of all machinery parts of the oil accumulated places.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 August 2023
Resolved
07199 - Other (fire safety)- Ignition sources shall be separated from combustible materials and liquids. PSCO observed cigarettes within the domestic garbage amongst combustible materials such as rags and paper next to gangway on the deck. 74SOLAS(20)II-2/4.1.5 - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 10 August 2023
Resolved 11 August 2023
Resolution: Received, reviewed and accepted class report from ClassNK stating the deficiency was rectified. The cigarettes have been disposed into the domestic garbage bin(Red) next to the gangway on the deck after completely extinguished.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 10 August 2023
Resolved
09298 - Other (accident prevention) - The essential importance of good housekeeping in the prevention of accidents to personnel, the elimination of fire hazards and the avoidance of any conditions on board likely to be injurious to seafarers' health. PSCO observed numerous damaged bags of hydrated lime dispersed on deck. SDS specifies skin and inhalation hazards associated with the hydrated lime, causing a danger for ships crewmembers in bosun hole. 46U.S.C.70002 ILO-147 p.44(a) - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 10 August 2023
Resolved 11 August 2023
Resolution: Received, reviewed and accepted class report from ClassNK stating the deficiency was rectified. Reorganized storage of the lime packages to put in 1 storage bag and keep the storage bag in bosun store. Cleaned the area of lime storage in bosun area.
14 - Pollution Prevention › 147 - Anti-Fouling › Other (AFS)
Issued 10 August 2023
Resolved
14799 - Other (AFS) - The master, owner, operator, agent or person in charge...must... remove fouling organisms from the vessels hull, piping, and tanks on a regular basis and dispose of any removed substances in accordance with local, state, and federal regulations. PSCO observed excess hull growth on the stern and port side of vessels hull.33CFR151.2050(f) - 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 February 2024
Resolution: Vessel provided Hull Cleaning Report attesting to proper hull growth removal.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 5 March 2019
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed the outboard engine on the rescue boat was not able to go astern.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 March 2019
Resolution: Received satisfactory class report from NKK attesting to the repair and operation of the vessel's rescue boats outboard motor.