MAURY USCG vessel records
← All vessels

CHINOOK

CHINOOK is a 2017 passenger vessel (inspected). The Coast Guard has recorded 8 inspections since 2018, most recently in April 2024, along with 4 deficiencies — 1 with no resolution recorded —.

Records from 2018 to 2024. Most recent: inspection, 21 April 2024.

Built
2017
Last inspected
21 April 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 21 April 2024
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2018–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

1485799
Flag
UNITED STATES
Maury page id
psix-1485799

Documentation record

Tonnage as PSIX records it1 - Simplified, Gross Ton
1 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 8

21 April 2024 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7898924
14 March 2024 Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7879499
24 March 2023 Drydock Exam · Annual Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7662140
25 April 2022 Drydock Exam · Annual Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7436264
2 April 2021 Drydock Exam · COI Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7167817
22 July 2020 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7070304
13 March 2019 DAPI Audit · Annual Inspection · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6641758
2 March 2018 DAPI Audit · Internal Structural Exam · Drydock Extension · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6364849

Deficiency record · 4

01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 March 2024 No resolution recorded
46 CFR 2.10-101(b); THE VESSEL OWNER OR OPERATOR MUST PAY THE ANNUAL VESSEL INSPECTION FEE EACH YEAR ON OR BEFORE THE VESSEL'S USER FEE ANNIVERSARY DATE. THE USER FEES FOR THE CHINOOK OUTSTANDING BALANCES WITH INTEREST ACCRUING FOR CY20, AND NO FEES LISTED FOR FOLLOWING YEARS. NO PAYMENT LISTED FOR MOST RECENT ANNUAL.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2024 — due date passed with no resolution recorded
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 March 2024 Resolved
All observed unsafe practices and other hazardous situations must be corrected. External leaks identified in inflatable collar during pressure test.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 March 2024
Resolved 12 April 2024
Resolution: Received video of repair and soap/leak test performed. No leaks observed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 March 2024 Resolved
The design, construction and stowage of portable tanks and related fuel lines and accessories must meet the requirements of ABYC H-25. Portable gasoline fuel tank for outboard engine is not properly secured to the vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 March 2024
Resolved 12 April 2024
Resolution: Witnessed sufficient straps holding down fuel tank.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 2 April 2021 Resolved
Noted air leaking on the stbd quarter
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2021
Resolved 14 April 2023
Resolution: Def left open from 13APR2021, as of an annual conducted on 03/24/23 no leaks were observed. Clearing def.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.