MAURY USCG vessel records
← All vessels

HAPPY HOUR

HAPPY HOUR is a 2018 passenger vessel (inspected). The Coast Guard has recorded 13 inspections since 2018, most recently in April 2026, along with 35 deficiencies.

Records from 2018 to 2026. Most recent: inspection, 7 April 2026.

Built
2018
Last inspected
7 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

1485913
Flag
UNITED STATES
Maury page id
psix-1485913

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 9 calendar years (2018–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)60.0 ft × 18.0 ft × 3.8 ft
Registered tonnagegross 21 / net 21
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRAMM MFG INC · ISLE · built 2018
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeBox
Hull configurationTri Hull
Hailing portMURRELLS INLET, SC
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 18 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it21 - Simplified, Gross Ton
21 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 13

7 April 2026 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8344578
10 April 2025 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8109618
3 March 2025 Internal Structural Exam · Drydock Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8087825
11 January 2024 COI Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7848313
1 March 2023 Internal Structural Exam · Drydock Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7643870
11 January 2023 Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7620214
3 September 2022 Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7550291
14 January 2022 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7375043
26 March 2021 Deficiency Check · Internal Structural Exam · Drydock Exam · Examination of Repairs · Hull Examination
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7165005
19 November 2020 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7094062
11 February 2019 Construction Oversight · Plan Review "T" Boat
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6624010
13 June 2018 Initial Certification · Construction Oversight · COI Inspection · Deadweight Survey · Examination of Repairs · Deficiency Check · Administrative Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6443008
8 February 2018 Construction Oversight
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 6352658

Deficiency record · 35

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 January 2022 Resolved
Vessel required to be equipped with bilge pumps capable of dewatering all compartments. Existing flexible piping at discharge of pumps are leaking. The male nipples that connect the hose to the pump(s) are too short.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2022
Resolved 3 September 2022
Resolution: MI verified repairs completed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 January 2022 Resolved
Vessels ring life buoy required to be equipped with a water light. Existing water light battery requires renewal.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2022
Resolved 3 September 2022
Resolution: MI verfied repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 January 2022 Resolved
Vessel required to be marked with PFD donning instructions at/near PFD storage locations. Vessel missing a PFD donning instruction on the upper deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2022
Resolved 3 September 2022
Resolution: MI verified PFD Donning instructions.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 January 2022 Resolved
Vessel required to be equipped with emergency fuel shut-off valves. Existing fuel shut off valves are not properly marked to indicate operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2022
Resolved 3 September 2022
Resolution: MI verified markings.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 26 March 2021 Resolved
The scope of a drydock examination included examination of all accessible parts of vessels underwater body including hull plating and appendages. Existing weldments IWO transverse deck structure @ pontoon mountings contained discontinuities, i.e.: porosity.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2021
Resolved 29 March 2021
Resolution: Attending Inspector(s) verified repairs to weldments.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 March 2021 Resolved
Vessel required to be equipped with fixed bilge piping system. Epoxy was found on fixed bilge piping weld joints. The epoxy was used to seal the joint to ensure bilge suction.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2021
Resolved 29 March 2021
Resolution: Attending Inspector(s) verified repairs to fixed bilge piping.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 March 2021 Resolved
Vessels installed electrical conductors are required to be supported with metal clamps spaced not more than 24" apart. Electrical conductors are currently supported with electrical tape along the fixed bilge piping.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2021
Resolved 29 March 2021
Resolution: Attending Inspector(s) verified installation of electrical supports for conductors.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 March 2021 Resolved
Vessels flexible bilge hose connections are required to be fitted with clamps. Existing clamps are corroded/wasted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2021
Resolved 31 August 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 March 2021 Resolved
Vessel required to be equipped with fixed bilge piping system. Existing flexible bilge suction piping was found kinked IWO center void #3.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2021
Resolved 31 August 2021
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 26 March 2021 Resolved
The scope of an internal structural examination includes a complete examination of the vessels main strength members, including the major internal framing, the hull plating and voids. Attending Inspector(s) identified various weld discontinuities/fractures IWO all three pontoons. Affected areas were marked and discussed with O/O.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2021
Resolved 29 March 2021
Resolution: Attending Inspector(s) verified repairs to weldments.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 19 November 2020 Resolved
Vessel required to be equipped with proper type/qty of visual distress signals for assigned route (LBS). Vessel is equipped with four red flares (requires three red (day)/three orange (day) flares.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2020
Resolved 31 August 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 November 2020 Resolved
Vessel required to carry proper type/qty of Type I PFD's for each person on board. Vessel missing five adult sized PFD's (requires total of one-hundred twenty-four to be carried at all times).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2020
Resolved 10 February 2021
Resolution: Attending Inspector(s) verified carriage of adult Type I PFD's.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 November 2020 Resolved
Vessel required to be fitted with emergency escapes. Existing emergency escape door(s) in way of port and starboard sides of vessel are misaligned.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2020
Resolved 14 January 2022
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 15 October 2019 Resolved
Vessel's original Certificate of Documentation was not available/posted on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 9 January 2020
Resolution: Attending Inspector(s) verified carriage/posting of COD.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 October 2019 Resolved
Owner/Operator was not able to produce a proof of enrollment certificate/documentation for recognized consortium.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 19 November 2020
Resolution: Attending Inspector(s) verified proof of enrollment in an recognized consortium.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 October 2019 Resolved
Companies Employee Assistance Program (EAP) was not implemented/documented.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 9 January 2020
Resolution: Attending Inspector(s) verified carriage/implementaton of EAP (program).
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 October 2019 Resolved
PFD stowage locations were not properly marked/identified with qty/size of PFD's.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 19 November 2020
Resolution: Attending Inspector(s) verified PFD stowage markings.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 October 2019 Resolved
Vessel not equipped with proper quantity of child sized PFD's (requires 12 @ 10%).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 10 February 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 October 2019 Resolved
Vessel's portable fire extinguishers are not secured with proper type/size brackets.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 10 February 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 October 2019 Resolved
Vessel not equipped with at least two (2) ring life buoys fitted with light/line.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 19 November 2020
Resolution: Attending Inspector(s) verified carriage of two (2) ring life buoy's.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 October 2019 Resolved
Vessel's ring life buoy's are not equipped with retro-reflective markings.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 9 January 2020
Resolution: Attending Inspector(s) verified markings for ring life buoys.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 October 2019 Resolved
Vessel not equipped with proper size/type of bell (sound producing device).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 9 January 2020
Resolution: Attending Inspector(s) verified carriage of proper type/size bell.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 15 October 2019 Resolved
Vessel not equipped with a magnetic compass at the operator's station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 19 November 2020
Resolution: Attending Inspector(s) verified vessel is not required to be fitted with magnetic compass due to operating on short/restricted routes.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 15 October 2019 Resolved
Vessel's watertight hatch covers for sponsons are not equipped with proper type/style of gasketing.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2019
Resolved 14 January 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 October 2019 Resolved
Expired items noted IWO first aid kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 19 November 2020
Resolution: Attending Inspector(s) verified condition/contents of first aid kits.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 October 2019 Resolved
Fuel fill pipes are not properly grounded.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 9 January 2020
Resolution: Attending Inspector(s) verified installation of grounding/bonding straps.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 October 2019 Resolved
Provide markings for fuel fill(s).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 9 January 2020
Resolution: Attending Inspector(s) verified markings for fuel fills.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 October 2019 Resolved
Emergency fuel shut-off valves were not properly marked/identified.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 19 November 2020
Resolution: Attending Inspector(s) verified markings for emergency fuel shut off valves.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 15 October 2019 Resolved
Operating instructions not posted IWO installed toilets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 9 January 2020
Resolution: Attending Inspector(s) verified posting of operating instructions for MSD/toilet.
09 - Working and Living Conditions › 092 - Working Conditions › Other (mooring)
Issued 15 October 2019 Resolved
Vessel not equipped with proper type/size of ground tackle.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 19 November 2020
Resolution: Attending Inspector(s) verified presence of proper type/size ground tackle.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 October 2019 Resolved
Vessel not equipped with proper type/qty of trash receptacles.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 9 January 2020
Resolution: Attending Inspector(s) verified carriage of proper type of waste receptacles.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 15 October 2019 Resolved
Vessel not equipped with draft/loading marks.
Action required: 705 - Other - as specified
Due 14 May 2021
Resolved 1 March 2023
Resolution: Loading mark painted on the outboard hulls
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 October 2019 Resolved
Vessels installed fire pump not equipped with pressure gauge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 14 January 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 October 2019 Resolved
Fire pump hose not equipped with proper size/type gasketing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 19 November 2020
Resolution: Attending Inspector(s) verified condition of fire hose/gasketing.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 June 2018 Resolved
Vessel's internal framing is not installed as per approved plans. Corrections to be addressed at next scheduled dry-dock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 May 2021
Resolved 26 March 2021
Resolution: See MSC Letter H1-1902317 dated July 16, 2019.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.