Records from 2018 to 2026. Most recent: inspection, 7 April 2026.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 January 2022
Resolved
Vessel required to be equipped with bilge pumps capable of dewatering all compartments. Existing flexible piping at discharge of pumps are leaking. The male nipples that connect the hose to the pump(s) are too short.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2022
Resolved 3 September 2022
Resolution: MI verified repairs completed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 January 2022
Resolved
Vessels ring life buoy required to be equipped with a water light. Existing water light battery requires renewal.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2022
Resolved 3 September 2022
Resolution: MI verfied repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 January 2022
Resolved
Vessel required to be marked with PFD donning instructions at/near PFD storage locations. Vessel missing a PFD donning instruction on the upper deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2022
Resolved 3 September 2022
Resolution: MI verified PFD Donning instructions.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 January 2022
Resolved
Vessel required to be equipped with emergency fuel shut-off valves. Existing fuel shut off valves are not properly marked to indicate operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2022
Resolved 3 September 2022
Resolution: MI verified markings.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 26 March 2021
Resolved
The scope of a drydock examination included examination of all accessible parts of vessels underwater body including hull plating and appendages. Existing weldments IWO transverse deck structure @ pontoon mountings contained discontinuities, i.e.: porosity.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2021
Resolved 29 March 2021
Resolution: Attending Inspector(s) verified repairs to weldments.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 March 2021
Resolved
Vessel required to be equipped with fixed bilge piping system. Epoxy was found on fixed bilge piping weld joints. The epoxy was used to seal the joint to ensure bilge suction.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2021
Resolved 29 March 2021
Resolution: Attending Inspector(s) verified repairs to fixed bilge piping.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 March 2021
Resolved
Vessels installed electrical conductors are required to be supported with metal clamps spaced not more than 24" apart. Electrical conductors are currently supported with electrical tape along the fixed bilge piping.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2021
Resolved 29 March 2021
Resolution: Attending Inspector(s) verified installation of electrical supports for conductors.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 March 2021
Resolved
Vessels flexible bilge hose connections are required to be fitted with clamps. Existing clamps are corroded/wasted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2021
Resolved 31 August 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 March 2021
Resolved
Vessel required to be equipped with fixed bilge piping system. Existing flexible bilge suction piping was found kinked IWO center void #3.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2021
Resolved 31 August 2021
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 26 March 2021
Resolved
The scope of an internal structural examination includes a complete examination of the vessels main strength members, including the major internal framing, the hull plating and voids. Attending Inspector(s) identified various weld discontinuities/fractures IWO all three pontoons. Affected areas were marked and discussed with O/O.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2021
Resolved 29 March 2021
Resolution: Attending Inspector(s) verified repairs to weldments.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 19 November 2020
Resolved
Vessel required to be equipped with proper type/qty of visual distress signals for assigned route (LBS). Vessel is equipped with four red flares (requires three red (day)/three orange (day) flares.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2020
Resolved 31 August 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 November 2020
Resolved
Vessel required to carry proper type/qty of Type I PFD's for each person on board. Vessel missing five adult sized PFD's (requires total of one-hundred twenty-four to be carried at all times).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2020
Resolved 10 February 2021
Resolution: Attending Inspector(s) verified carriage of adult Type I PFD's.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 November 2020
Resolved
Vessel required to be fitted with emergency escapes. Existing emergency escape door(s) in way of port and starboard sides of vessel are misaligned.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2020
Resolved 14 January 2022
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 15 October 2019
Resolved
Vessel's original Certificate of Documentation was not available/posted on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 9 January 2020
Resolution: Attending Inspector(s) verified carriage/posting of COD.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 October 2019
Resolved
Owner/Operator was not able to produce a proof of enrollment certificate/documentation for recognized consortium.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 19 November 2020
Resolution: Attending Inspector(s) verified proof of enrollment in an recognized consortium.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 October 2019
Resolved
Companies Employee Assistance Program (EAP) was not implemented/documented.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 9 January 2020
Resolution: Attending Inspector(s) verified carriage/implementaton of EAP (program).
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 October 2019
Resolved
PFD stowage locations were not properly marked/identified with qty/size of PFD's.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 19 November 2020
Resolution: Attending Inspector(s) verified PFD stowage markings.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 October 2019
Resolved
Vessel not equipped with proper quantity of child sized PFD's (requires 12 @ 10%).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 10 February 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 October 2019
Resolved
Vessel's portable fire extinguishers are not secured with proper type/size brackets.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 10 February 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 October 2019
Resolved
Vessel not equipped with at least two (2) ring life buoys fitted with light/line.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 19 November 2020
Resolution: Attending Inspector(s) verified carriage of two (2) ring life buoy's.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 October 2019
Resolved
Vessel's ring life buoy's are not equipped with retro-reflective markings.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 9 January 2020
Resolution: Attending Inspector(s) verified markings for ring life buoys.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 October 2019
Resolved
Vessel not equipped with proper size/type of bell (sound producing device).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 9 January 2020
Resolution: Attending Inspector(s) verified carriage of proper type/size bell.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 15 October 2019
Resolved
Vessel not equipped with a magnetic compass at the operator's station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 19 November 2020
Resolution: Attending Inspector(s) verified vessel is not required to be fitted with magnetic compass due to operating on short/restricted routes.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 15 October 2019
Resolved
Vessel's watertight hatch covers for sponsons are not equipped with proper type/style of gasketing.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2019
Resolved 14 January 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 October 2019
Resolved
Expired items noted IWO first aid kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 19 November 2020
Resolution: Attending Inspector(s) verified condition/contents of first aid kits.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 October 2019
Resolved
Fuel fill pipes are not properly grounded.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 9 January 2020
Resolution: Attending Inspector(s) verified installation of grounding/bonding straps.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 October 2019
Resolved
Provide markings for fuel fill(s).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 9 January 2020
Resolution: Attending Inspector(s) verified markings for fuel fills.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 October 2019
Resolved
Emergency fuel shut-off valves were not properly marked/identified.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 19 November 2020
Resolution: Attending Inspector(s) verified markings for emergency fuel shut off valves.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 15 October 2019
Resolved
Operating instructions not posted IWO installed toilets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 9 January 2020
Resolution: Attending Inspector(s) verified posting of operating instructions for MSD/toilet.
09 - Working and Living Conditions › 092 - Working Conditions › Other (mooring)
Issued 15 October 2019
Resolved
Vessel not equipped with proper type/size of ground tackle.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 19 November 2020
Resolution: Attending Inspector(s) verified presence of proper type/size ground tackle.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 October 2019
Resolved
Vessel not equipped with proper type/qty of trash receptacles.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 9 January 2020
Resolution: Attending Inspector(s) verified carriage of proper type of waste receptacles.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 15 October 2019
Resolved
Vessel not equipped with draft/loading marks.
Action required: 705 - Other - as specified
Due 14 May 2021
Resolved 1 March 2023
Resolution: Loading mark painted on the outboard hulls
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 October 2019
Resolved
Vessels installed fire pump not equipped with pressure gauge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 14 January 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 October 2019
Resolved
Fire pump hose not equipped with proper size/type gasketing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 19 November 2020
Resolution: Attending Inspector(s) verified condition of fire hose/gasketing.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 June 2018
Resolved
Vessel's internal framing is not installed as per approved plans. Corrections to be addressed at next scheduled dry-dock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 May 2021
Resolved 26 March 2021
Resolution: See MSC Letter H1-1902317 dated July 16, 2019.