Records from 2018 to 2026. Most recent: inspection, 20 March 2026.
Inspection history · 11
20 March 2026
Deficiency Check · Annual Inspection · Drydock Exam
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 8328416
25 February 2025
Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 8084096
14 March 2024
Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7892073
4 April 2023
COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7662190
22 March 2022
Drydock Exam · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7422523
23 April 2021
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7182021
4 December 2020
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7106519
2 July 2020
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7005522
27 May 2020
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6962124
1 April 2019
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6654016
9 February 2018
Initial Certification · Plan Review "T" Boat · DAPI Audit · Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6352858
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 March 2026
Resolved
Exhaust blower duct must lead as directly as possible from its intake opening to its terminus and be securely fastened and supported. Exhaust blower intake was not connected. Connect exhaust blower intake.
46 CFR 182.460(h)
Action required: 10 - Deficiency Rectified
Resolved 20 March 2026
Resolution: Vent intake properly connected.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 20 March 2026
Resolved
A complete application for an original MMC must contain proof, documented on CG-719-K or CG-719-K/E, as appropriate, that the applicant passed all applicable vision, hearing, medical, and/or physical exams as required by subpart C of this part or a valid medical certificate issued by the Coast Guard. The Master did not have his medical certificate available. Provide master who has valid medical certificate to meet manning requirements.
46 CFR 10.302(a)
Action required: 10 - Deficiency Rectified
Resolved 20 March 2026
Resolution: New master provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 March 2026
Resolved
Battery installations must be mounted 46 CFR 183.350 to protect against shifting of the vessel and free from exposure to water splash or spray. Battery was not secure to prevent movement. Provide means to secure battery.
46 CFR 183.350
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2026
Resolved 24 June 2026
Resolution: Battery secured.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 20 March 2026
Resolved
A hatch cover must have securing devices and be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. Provide hatch cover securing device.
46 CFR 179.360
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2026
Resolved 24 June 2026
Resolution: Keeper chain provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 March 2026
Resolved
In systems and applications where flexible hoses are permitted to be clamped: Double hose clamping is required where practicable. Missing double hose clamp on bilge system. Provide double hose clamps.
46 CFR 182.410 (d)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2026
Resolved 24 June 2026
Resolution: Double hose clamps provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 March 2026
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Fuel fitting at fuel tank where shut off valve located was moving when operating the fuel shut off. Make fuel line and fitting tight.
46 CFR 182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2026
Resolved 24 June 2026
Resolution: Fuel line fitting tightened.
Fire Fighting › Ventilation Systems › Ducts
Issued 9 February 2018
Resolved
46 CFR 182.460(a)(1) requires two supply and two exhaust vents with mechanical blower for each enclosed space containing a gasoline fuel tank. The vessel does not have the required ventilation. Provide the required ventilation by 31DEC2018.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 1 April 2019
Resolution: The compartment that houses the fuel tank and the bilge are considered to be partially enclosed and there for do not require fixed mechanical blowers.