MAURY USCG vessel records
← All vessels

ALGOMA SAULT

ALGOMA SAULT is a freight ship. The Coast Guard has recorded 19 inspections since 2018, most recently in October 2025, along with 4 deficiencies.

Records from 2018 to 2025. Most recent: inspection, 29 October 2025.

Built
Not recorded
Last inspected
29 October 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 29 October 2025
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2018–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9619282
1486938
Flag
CANADA
Maury page id
psix-1486938

Documentation record

Tonnage as PSIX records it36908 - Dead Weight, Metric Ton
47343 - Displacement, Metric Ton
24640 - Convention (Subpart B), Gross Ton
8975 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

WYOMING Towing Vessel · MISLE 58198 · 24 May 2018 · activity 6422577

Inspection history · 19

29 October 2025 PSC B · Canadian Vsl Safety Exam (D9 only)
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8260346
1 October 2025 Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8244482
25 March 2024 PSC B · Canadian Vsl Safety Exam (D9 only)
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7882503
26 June 2023 Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7724582
3 April 2023 Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7662081
19 November 2022 MARPOL Annex I Examination · MARPOL Annex V Examination · MARPOL Annex VI Survey
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7594898
24 August 2022 Type not recorded
No type recorded · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7542574
20 July 2022 Canadian Vsl Safety Exam (D9 only) · PSC B
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7511857
12 April 2021 Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7173340
26 March 2021 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7163204
10 January 2021 Canadian Vsl Safety Exam (D9 only)
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7122207
20 August 2020 Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7038253
4 June 2020 Administrative Inspection
Administrative · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6968014
2 October 2019 Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6826168
24 June 2019 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6725159
3 May 2019 Canadian Vsl Safety Exam (D9 only)
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6675832
24 May 2018 Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6422577
10 May 2018 Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6410701
30 April 2018 ISPS II Exam · Canadian Vsl Safety Exam (D9 only)
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6402754

Deficiency record · 4

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 March 2024 Resolved
07109-Where provisions are made for the simultaneous release of a given amount of CO2 by operation of remote control, provisions shall also be made for manual control at the cylinders. Each of the pilot cylinders shall be capable of manual control at the cylinder, but the remaining cylinders need not be capable of individual manual control.Examiners found missing hose in actuator line, separating 09 cylinders from being activated by pilot cylinder. Crew replaced missing hose with last hose from the cylinder bank and fabricated new hose for last cylinder. - 46 CFR 95.15-10(e) 50a
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2024
Resolved 3 April 2024
Resolution: Receieved repair and class approval documentation for hose repair.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 June 2023 Resolved
FOR VOYAGES LESS THAN 96 HOURS, VESSELS MUST SUBMIT AN NOA BEFORE DEPARTURE BUT AT LEAST 24 HOURS BEFORE ENTERING THE PORT OR PLACE OF DESTINATION. VESSEL DID NOT SUBMIT AN NOA AT LEAST 24 HOURS BEFORE ARRIVING TO THE PORT OF TOLEDO. 33 CFR 160.212(a)(4)(ii)
Action required: 10 - Deficiency Rectified
Due 14 July 2023
Resolved 14 July 2023
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 26 March 2021 Resolved
S band radar inoperable
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 6 April 2021
Resolved 28 March 2021
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 10 January 2021 Resolved
Vessel has self-closing door fire rated in stair tower Upper Deck Level that will not close/latch properly during test. Perform maintenance/repair fire rated self-closing door and perform testing to the satisfaction of classification society.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2021
Resolved 17 February 2021
Resolution: Vessel captain states deficiency corrected by Chief engineer after CVSE compeleted. Class still scheudled to verify system still watching properly in MAR 2021.

Ownership record