MISS JACKIE is a 2018 passenger vessel (inspected). The Coast Guard has recorded 15 inspections since 2017, most recently in May 2026, along with 12 deficiencies and 1 operational control.
Records from 2017 to 2026. Most recent: inspection, 19 May 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Registered dimensions (L × B × D)46.0 ft × 16.0 ft × 9.0 ft
Registered tonnagegross 44 / net 35
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNEWTON BOATS INC · SLIDELL, LA, UNITED STATES · built 2018
Hull materialFRP (Fiberglass)
PropulsionDiesel Direct
Hull shapeShip
Hull configurationMonohull
Hailing portMARATHON, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 27 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it44 - Simplified, Gross Ton 35 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
What it gives that this page does not: the whole record in one
dated, citable document — every line with its Coast Guard activity id, the retrieval
date on the cover, built to print to PDF with its page breaks — that a surveyor can
attach and a lender can file. The same facts as this page, complete and in one file.
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
A request, not a checkout: leave an email and Maury replies once, with
the dated document for this hull and a Stripe invoice for $299. Nothing is charged before
the document is in your hands.
Used only to answer this request.
Not shared, not sold, and not added to a mailing list.
Inspection history · 15
19 May 2026Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8380795
14 May 2026Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8373117
22 April 2025Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8090155
21 May 2024Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7916141
16 May 2024Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7913331
11 August 2023Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7765611
9 May 2023Annual Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7667839
1 June 2022DAPI Audit · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7465720
10 May 2022Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7447340
9 March 2021Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7153080
27 February 2021Type not recorded
No type recorded · Station Marathon · USCG Southeast District (CGD-SE) · Activity 7147360
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 22 April 2025Resolved
New retro tape needs to be placed on life float.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2025
Resolved 24 April 2025
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 22 April 2025Resolved
Both flash lights are not working. Replace or fix flash lights to working order.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2025
Resolved 24 April 2025
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 22 April 2025Resolved
Fire dampners need to operate in a smooth open and closed positions. Fix vent dampners to a proper working operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2025
Resolved 24 April 2025
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 21 May 2024Resolved
EPIRB battery expired April 2024. Must send EPIRB in for servicing/battery replacement or buy a new EPIRB and have it registered.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2024
Resolved 1 June 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 May 2024Resolved
Life ring was missing SOLAS reflective tape. Must add 4 bands on each side with SOLAS reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2024
Resolved 1 June 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 March 2021Resolved
Fire buckets onboard were 2 gallons each. Requirements are for 3 buckets that are 2.5 gallons each. Must replace buckets with correct size and label properly prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 March 2021
Resolved 9 March 2021
Resolution: Received picture with 3, three gallon buckets properly labeled and with lanyards attached
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical care
Issued 9 March 2021Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 March 2021
Resolved 11 May 2021
Resolution: Received pictures of Captains FCC permit
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 9 March 2021Resolved
First aid kit has expired items. Must replace all expired items and or missing items to meet requirements in 46 CFR 160.041
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2021
Resolved 11 May 2021
Resolution: Received picture of items replaced in first aid kit
Owner just bought this vessel couple weeks ago. There is no crew training log to show training was conducted on all the safety equipment prior to getting underway for the first time. Captain did not no how to work the installed fire system for the main diesel engines after two weeks operating the vessel. Must provide crew training to all crew members on the safety items on the vessel.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2021
Resolved 11 May 2021
Resolution: Received pics of new log books
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 9 March 2021Resolved
1 of the portable lights was not working. Must make repairs and test to the satisfaction of attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2021
Resolved 9 March 2021
Resolution: Received picture of both portable lights working.
Hailing port on stern still has old port from previous owner. Must replace hailing port name with new current home port.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2021
Resolved 10 March 2021
Resolution: Removed old hailing port and added new hailing port
The vessel is required to have a valid FCC Safety Radiotelephony Certificate. The vessel did not have a valid FCC Safety Radiotelephony Certificate. The vessel owner is required to prvide a valid FCC Safety Radiotelephony Certificate for the vessel.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 28 May 2018
Resolved 23 May 2018