MAURY USCG vessel records
← All vessels

DOC

DOC is a 2018 passenger vessel (inspected). The Coast Guard has recorded 8 inspections since 2018, most recently in January 2024, along with 15 deficiencies and 1 operational control.

Records from 2018 to 2024. Most recent: inspection, 24 January 2024.

Built
2018
Last inspected
24 January 2024
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDM8196
1488518
Flag
UNITED STATES
Maury page id
psix-1488518

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 6 calendar years (2018–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)44.0 ft × 10.3 ft × 4.0 ft
Registered tonnagegross 12 / net 12
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHUNTER MARINE GROUP LLC · MARRERO, LA, UNITED STATES · built 2018
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portBENICIA, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 12 August 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it12 - Simplified, Gross Ton
12 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 8

24 January 2024 Internal Structural Exam · Annual Inspection · Drydock Exam · Hull Examination · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7851142
11 April 2023 Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7665749
19 May 2022 Internal Structural Exam · Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7452775
14 February 2022 Internal Structural Exam · Drydock Exam · Hull Examination · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7396177
13 April 2021 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7174191
31 March 2020 Administrative Inspection · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6934811
19 February 2020 Drydock Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6911802
12 February 2018 Initial Certification · Internal Structural Exam · Plan Review "T" Boat · Simplified Stability Test · Construction Oversight · Hull Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6498303

Deficiency record · 15

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 January 2024 Resolved
Electrical equipment used in the following locations must be drip proof: location normally exposed to splashing. Electrical outlets and wiring under the operating console found not drip proof and showing signs of corrosion from contact with water. This area is subject to water ingress from the main access door. 46CFR184.710
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2024
Resolved 7 February 2024
Resolution: Receiveed photo from POC of added plexiglass that will protect wiring def cleared.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 24 January 2024 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Vessels first aid kit found with required contents expired. Replace all expired contents. 46CFR183.210(a)(2)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2024
Resolved 9 February 2024
Resolution: Vessel rep submitted photos of the newly purchased first aid kit and supplies. Def Cleared, photo added to documents.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 24 January 2024 Resolved
The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Vessel was unable to provide records of required servicing of the vessel’s fire boy system. Provide evidence of the required servicing to the satisfaction of the Marine Inspector. 46CFR176.810(b)(2)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2024
Resolved 1 February 2024
Resolution: Received satisfactory fire servicing record. Def cleared.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 11 April 2023 Resolved
A vessel must comply with the applicable requirements for any radio...requirements for a station license and installation certificates to be issued by the Federal Communications Commission. Each ship transporting more than six passengers for hire...must carry a radio operator. The marine radio operator permit for the master was not available. Operator permit must be obtained.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2023
Resolved 20 April 2023
Resolution: Received satisfactory photograph of radio operator permit.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 11 April 2023 Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Fixed-gas fire extinguishing system service records must be provided.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2023
Resolved 20 April 2023
Resolution: Receieved satifactory fire service record.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 11 April 2023 Resolved
A hatch cover must: (2) Be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. Lazarette hatch cover lanyard must be replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2023
Resolved 20 April 2023
Resolution: Received satisfactory photograph of hatch cover lanyard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 May 2022 Resolved
Each life jacket must be approved in accordance with 46 CFR 160.002, 160005, or 160.055 in subchapter Q of this subchapter. Vessel had on board, 13 life jackets that were of another coast guard approval series. Vessel limited to 15 total adult persons on board.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2022
Resolved 24 May 2022
Resolution: Confirmed new life jackets in service. All POB life jackets accounted for.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 May 2022 Resolved
A space containing fuel tanks for gasoline must have a ventilation system that complies with this section and consists of: A mechanical exhaust system...which extend to the lowest part of the bilge of the space on each side of the space. Starboard side blower does not have any suction. This includes space for gasoline and diesel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2022
Resolved 24 May 2022
Resolution: Attended to witness starboard blower operation after repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 May 2022 Resolved
A space containing fuel tanks for gasoline must have a ventilation system that complies with this section and consists of: A mechanical exhaust system...which extend to the lowest part of the bilge of the space on each side of the space. Blowers uptake do not extend to the lowest part of the bilge. This includes space for gasoline and diesel.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2022
Resolved 2 June 2022
Resolution: Vessel sent photo of ducting extended to lowest part of bilge possible.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 19 May 2022 Resolved
Each survival craft must be stowed so that when the vessel sinks the survival craft floats free and, if inflatable, inflates automatically. Vessel's Hydrostatic Release Unit is improperly routed.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2022
Resolved 24 May 2022
Resolution: Attended to witness proper installation of HRU and IBA securing setup.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 May 2022 Resolved
Fuel tanks must be adequately supported and braced to prevent movement. Several bolts on gasoline and diesel tank braces are undersized (length) to the nut. Standard sizing would allow threads to extend beyond the nut. One brace is missing a bolt on the gasoline tank.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2022
Resolved 24 June 2022
Resolution: Attended to witness installation of proper fasteners.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 14 February 2022 Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician once every five years. The vessel's Safety Radiotelephony Certificate expired in 2021. 47 CFR 80.903
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 March 2022
Resolved 3 March 2022
Resolution: Received renewed certificate copy.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 13 April 2021 Resolved
Annual servicing and Inspections on fire extinguishing systems are required by Table 46 CFR 176.810(b), in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Discovered that the fire extinguishing system has not been serviced by a USCG approved facility in over a year period. 46CFR176.810(b)(2)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 April 2021
Resolution: Received satisfactory proof of fireboy servicing.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 13 April 2021 Resolved
Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present, such as machinery spaces and paint lockers. Discovered that the fuel tank space was not vapor tight. Operator must ensure all spaces where flammable and combustible liquids are present that these spaces are vapor tight. 46 CFR 177.405 (c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 April 2021
Resolution: Received photo of fire caulk installed in wire run between fuel tank space and diesel cargo space.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 April 2021 Resolved
An enclosed space containing machinery powered by gasoline must be equipped with a flammable vapor detection device in compliance with 46 CFR 182.480. Discovered that the vessel has not been keeping its flammable vapor detection device in compliance to 46 CFR 182.480 and were unable to exhibit its proper operation to the USCG marine inspectors. 46CFR182.410(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 April 2021
Resolution: Received video showing proper testing and operation of vapor detection device.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.