Records from 2018 to 2025. Most recent: inspection, 9 December 2025.
Documentation record
Registered dimensions (L × B × D)50.0 ft × 14.0 ft × 3.2 ft
Registered tonnagegross 6 / net 6
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSIGHTSEER MARINE PRODUCTS INC · HUDSON, FL, UNITED STATES · built 2018
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portKEY WEST, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 12 August 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it6 - Simplified, Gross Ton
6 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 13
9 December 2025
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8291287
22 April 2025
Damage Survey · Administrative Inspection · Examination of Repairs · In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8116814
20 April 2025
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8117520
23 September 2024
COI Inspection · Plan Review "T" Boat
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8008542
7 August 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7971337
22 February 2024
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7868796
18 August 2021
Damage Survey
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7316664
17 August 2021
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7295435
23 June 2020
Deficiency Check · Internal Structural Exam · Hull Examination · COI Inspection · DAPI Audit · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6978441
22 April 2020
Administrative Inspection
Administrative · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6952675
28 August 2019
Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6796907
25 May 2018
COI Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6429100
2 March 2018
Administrative Inspection · Deadweight Survey · Internal Structural Exam · Hull Examination · Construction Oversight
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6379673
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 December 2025
Resolved
Mount the 10-B:C portable fire extinguisher at the operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2025
Resolved 9 December 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 December 2025
Resolved
Mark the vessel's name in block capital letters on the ring life buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2025
Resolved 9 December 2025
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 9 December 2025
Resolved
Post a discharge of garbage placard and discharge of oil placard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2025
Resolved 9 December 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 April 2025
Resolved
Propulsion machinery msut be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations.
Vessel was moored and sustained damage from another vessel alliding into it. Affect permanent repairs to the satisfaction of a USCG Marine Inspector prior to departure and the carriage of passengers onboard.
46 CFR 182.200 (a)
Action required: 17 - Rectify deficiencies prior to departure
Due 29 April 2025
Resolved 2 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 June 2020
Resolved
In addition, a number of child size life jackets equal to at least 10% of the number of persons permitted on board must be provided, or such greater number as necessary to provide a life jacket for each person being carried that is smaller than the lower size limit of the adult life jackets provided to meet this section.
Missing 1 child life jacket and storage areas not properly marked for both adult and child jackets.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2020
Resolved 13 July 2020
Resolution: Replaced life jackets
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 June 2020
Resolved
A vessel not required to have a power driven fire pump by §181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket.
Missing two fire buckets and one present not marked.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2020
Resolved 13 July 2020
Resolution: Labeled and put 2 more fire buckets in service on the vessel
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 June 2020
Resolved
A portable hand bilge pump must be:
(1) Capable of pumping water, but not necessarily simultaneously, from all watertight compartments; and
(2) Provided with suitable suction hose capable of reach
the bilge of each watertight compartment and discharging overboard. Missing hand pump
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2020
Resolved 13 July 2020
Resolution: Placed a portable bilge pump in service on the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 June 2020
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh. Flame screens are installed in plastic fittings. replace or provide documentation that plastic is suitable for gasoline use.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2020
Resolved 24 November 2021
Resolution: Flame screens were placed in service.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 23 June 2020
Resolved
Each item of lifesaving equipment carried on board a vessel but not required under this part.
EPIRB is present but not registered to the current operator. Remove or update registration.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2020
Resolved 20 July 2020
Resolution: Removed epirb from the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 June 2020
Resolved
A suitable metal marine type strainer, meeting the requirements of the engine manufacturer, must be fitted in the fuel supply line in the engine.
Plastic bowls are installed on fuel filters.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2020
Resolved 20 July 2020
Resolution: Replced fuel filter with metal bowl.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 June 2020
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation.
Valves not marked.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2020
Resolved 20 July 2020
Resolution: Fuel shut offs were marked properly
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 June 2020
Resolved
Waste receptacles. Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom.
Plastic trash cans were present.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2020
Resolved 20 July 2020
Resolution: Plastic trash cans were replaced with metal cans.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 23 June 2020
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:
Charts of large enough scale to make safe navigation possible and navigation rules.
Was not present.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2020
Resolved 20 July 2020
Resolution: Chart of Lake Murray was placed in service on the vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 23 June 2020
Resolved
The official number of the vessel, preceded by the abbreviation “NO.” must be marked in block-type Arabic numerals not less than three inches in height on some clearly visible interior structural part of the hull. The number must be permanently affixed to the vessel so that alteration, removal, or replacement would be obvious. If the official number is on a separate plate, the plate must be fastened in such a manner that its removal would normally cause some scarring of or damage to the surrounding hull area.
ON was missing and Port side of vessel was labeled "ESCAPE"
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2020
Resolved 24 November 2021
Resolution: The official number was placed on the vessel.