← All vessels
CALYPSO.GR
CALYPSO.GR is a 2017 freight ship. The Coast Guard has recorded 12 inspections since 2018, most recently in February 2025, along with 3 deficiencies and 3 operational controls.
Records from 2018 to 2025. Most recent: inspection, 3 February 2025.
- Built
- 2017
- Last inspected
- 3 February 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 3 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9785134 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7ZE2
1489210
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1489210
Inspections, by type
…with no type recorded4
Years with a record
5 calendar years (2018–2025)
The 12 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it23296 - Convention (Subpart B), Gross Ton
37865 - Dead Weight, Metric Ton
46314 - Displacement, Metric Ton
12101 - Convention (Subpart B), Net Ton
37865 - Dead Weight, Metric Ton
46314 - Displacement, Metric Ton
12101 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 12
3 February 2025
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8073572
28 March 2022
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7419971
4 November 2021
Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7345612
14 September 2021
PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7311670
5 April 2019
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6656575
1 April 2019
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6653597
30 March 2019
ISPS II Exam · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6652393
12 December 2018
COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6596531
2 April 2018
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6377452
26 March 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6379209
23 March 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6377435
23 March 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6377689
Deficiency record · 3
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 14 September 2021
Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. The sample line from 15 PPM separator to waste oil tank was corroded and leaking at a rate of approximately 118 milliliters a minute.
74 SOLAS (20)II-1/26.1
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 14 September 2021
Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. The packing gland of the general service pump was leaking heavily, filling the surrounding containment.
74 SOLAS (20)II-1/26.1
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 14 September 2021
Resolved
General arrangement plans shall be permanently exhibited for the guidance of the ship's officers, showing clearly for each deck the control stations, the fire-extinguishing appliances serving each station. Helicopter locker containing 02 fire-fighting outfits is not indicated on vessel's fire control plan.
74 SOLAS (20)II-2/15.2.4.1
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.