Records from 2018 to 2026. Most recent: inspection, 15 May 2026.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)36.0 ft × 14.5 ft × 7.0 ft
Registered tonnagegross 24 / net 24
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNEWTON BOATS INC · SLIDELL, LA, UNITED STATES · built 2018
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portCHEBOYGAN, MI
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 10 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it24 - Simplified, Gross Ton
24 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
13 inspections, each with its date, unit and type; 9 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 13
15 May 2026
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8383456
21 May 2025
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8178081
24 February 2025
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8083920
9 May 2024
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7909474
10 May 2023
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7685054
15 February 2023
Internal Structural Exam · Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7637595
26 May 2022
COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7452940
21 June 2021
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7246538
17 June 2020
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6978943
6 August 2019
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6775116
6 November 2018
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6575314
29 August 2018
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6526599
30 March 2018
Simplified Stability Test · Construction Oversight · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6524541
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 26 May 2022
Resolved
Flares onboard were expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2022
Resolved 27 May 2022
Resolution: Corrected.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 6 August 2019
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: charts, U.S. Coast Pilot, and Coast Guard Light List. Vessel does not have an approved nautical chart or up to date Coast Pilot and Light List. Provide appropriate nautical chart and updated excerpts of the Coast Pilot and Light List.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2019
Resolved 13 September 2019
Resolution: Vessel attained up to date publications and chart.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 6 August 2019
Resolved
Vessel is required to have on board a valid FCC Safety certificate, as per 47 CFR 80.401. Vessel does not have FCC Safety certificate. Obtain FCC safety certificate for vessel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2019
Resolved 20 August 2019
Resolution: Copy of FCC safety certificate emailed to office
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 6 August 2019
Resolved
Vessel is required to have on board a Great Lakes Agreement certificate, as per 47 CFR 80.953. Vessel does not have a Great Lakes Agreement certificate. Obtain a Great Lakes Agreement certificate.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2019
Resolved 30 August 2019
Resolution: Vessel attained valid Great Lakes agreement certificate.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 August 2019
Resolved
Penetrations in a watertight bulkhead must be made watertight. On the vessel, an electrical cable penetrates each of the watertight bulkheads with no watertight fittings. Additionally, an electrical cable penetrates the transom with no watertight fitting. Ensure the aforementioned cable penetrations are watertight.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2019
Resolved 10 September 2019
Resolution: The cable pentrations through the bulkheads and transom were made watertight
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 August 2019
Resolved
All cable and wire must be installed in such a manner to be properly supported and avoid chafing and other damage. Multiple cables and wires in the most aft space are hanging without support. Properly support cables to avoid chafing and damage.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2019
Resolved 13 September 2019
Resolution: Cables and wires were made properly supported.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 6 August 2019
Resolved
A visual and audio alarm must be provided at the operating station to indicate a high water level in a space with a through hull fitting below the deepest load waterline. An audio and visual alarm for the forepeak does not exist and there is a through hull fitting. Install a visual and audio alarm at the operating station for high water in the forepeak.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2019
Resolved 13 September 2019
Resolution: Installed the bilge alarm in the forepeak. OPTEST sat
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 6 August 2019
Resolved
When operating on a body of water where the discharge of sewage is prohibited, the operator must secure each marine sanitation device (MSD) in a manner that prevents discharge of sewage. The MSD onboard the vessel has the ability to discharge overboard and is not properly secured. Secure the device in a manner to prevent discharge of sewage.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2019
Resolved 13 September 2019
Resolution: Zip tie is installed to secure the overboard discharge valve for the MSD.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 August 2018
Resolved
Electrical power feed, #10 AWG conductor from main positive bus to operating station distribution panel has insufficient overcurrent protection, must be replaced with proper size or or provided with proper overcurrent protection.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2018
Resolved 5 November 2018