Records from 2020 to 2026. Most recent: inspection, 16 July 2026.
Documentation record
Registered dimensions (L × B × D)55.6 ft × 11.5 ft × 7.3 ft
Registered tonnagegross 31 / net 31
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderROZEMA BOAT WORKS INC · MT VERNON, WA, UNITED STATES · built 2020
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portMA'ALAEA, HI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 August 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14177 - Dead Weight, Ton
35153 - Displacement, Ton
31 - Simplified, Gross Ton
31 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 13
16 July 2026
Drydock Exam
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8435035
19 November 2025
Deficiency Check · COI Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8270801
4 December 2024
Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8042836
25 July 2024
Drydock Exam · Internal Structural Exam
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 7967005
11 January 2024
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7847974
26 January 2023
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7627522
4 August 2022
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7524805
24 March 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7418064
14 September 2021
In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7311748
30 September 2020
Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7068763
22 September 2020
Deadweight Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7063890
26 April 2020
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6944082
12 February 2020
Administrative Inspection · Construction Oversight · Deadweight Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6908114
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 November 2025
Resolved
A vessel must comply with the applicable requirements for any radio installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Safety Radio certificate expired. Provide copy of FCC Safety Radio certificate with valid dates. 46 CFR 184.502
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 December 2025
Resolved 21 November 2025
Resolution: New FCC radio safety cert provided and installed on vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 March 2022
Resolved
A vessel must have 01 life ring buoy. The ring buoy on board was sun damaged. Provide new life ring buoy.
46 CFR 180.70
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2022
Resolved 21 April 2022
Resolution: New ring buoy provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 March 2022
Resolved
The employer shall provide an Employee Assistance Program for all crew members that includes both education and training on the effects and consequences of drug and alcohol use. No evidence of crew training or supervisory personnel 60 minute training. Provide evidence of required training completed.
46 CFR 16.401(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2022
Resolved 21 April 2022
Resolution: Drug training completed.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 24 March 2022
Resolved
As appropriate for the intended voyage a vessel must carry adequate and up-to-date Coast Guard Light List. Coast Guard Light List not provided. Provide updated Coast Guard Light List.
46 CFR 184.420(a)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2022
Resolved 21 April 2022
Resolution: Coast pilot provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 March 2022
Resolved
Each vessel must be equipped with at least two operable portable battery lights at the operating station and the propulsion space. Missing flashlights. Provide 02 flashlights.
46 CFR 183.430
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2022
Resolved 21 April 2022
Resolution: Flashlights provided.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 24 March 2022
Resolved
Drill log entry shall include general description of the drill scenario and training topics. Log missing description and topics. Provide description and topic.
46 CFR 185.524(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2022
Resolved 21 April 2022
Resolution: Logbook topics provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 March 2022
Resolved
Inflation of collars to be conducted in accordance with Work Instruction 07. Inflation not conducted due to pump not meeting the working pressure 3psi times 1.25 = 3.75. Provide adequate pump and gauge to conduct pressure test of collars.
Work Instruction 07
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2022
Resolved 4 May 2022
Resolution: Collars inflated.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 March 2022
Resolved
Exhaust blower switches must be of the type interlocked with the starting switch and the ignition switch so that the blowers are started before the engine starter motor circuit or the engine ignition is energized. Ventilation not interlocked with engine starter motor. Install and demonstrate interlocked system.
46 CFR 182.460(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2022
Resolved 21 June 2022
Resolution: Interlock provided.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 March 2022
Resolved
Provisions must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. Closure devices not at supply or exhaust. Provide closure devices.
46 CFR 182.460(l)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2022
Resolved 21 April 2022
Resolution: Closure devices provided.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 30 September 2020
Resolved
Provide appropriate storage and markings of child and adult life jackets.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2020
Resolved 10 November 2020