MAURY USCG vessel records
← All vessels

BUBBA-JOHN

Built
1977
Last inspected
16 July 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 16 July 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 9 calendar years (1994–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCO9248
149213
Flag
UNITED STATES
Maury page id
psix-149213

Documentation record

Registered dimensions (L × B × D)34.8 ft × 15.1 ft × 4.2 ft
Registered tonnagegross 23 / net 15
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRICHARD S. MORLEY · BOYCE LA, UNITED STATES · built 1977
Hull materialSteel
PropulsionDiesel
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portGALVESTON, TX
Endorsements, as the file codes themcw_un
DocumentationValid · issued 16 December 2025 · expires 31 January 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it40 - Dead Weight, Ton
23 - Regulatory (Subpart C or D), Gross Ton
15 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 16 inspections, each with its date, unit and type; 27 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 16

16 July 2026 Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8434479
25 June 2025 Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8168617
26 July 2024 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7967611
28 December 2023 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7843064
7 September 2023 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7786060
26 April 2023 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7675239
10 March 2023 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7649039
15 March 2022 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7483862
23 February 2022 Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7400639
25 November 2020 Administrative Inspection · Initial Certification · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7097836
26 October 2020 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7086033
5 October 2020 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7071690
12 June 2012 Administration
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4341659
22 June 2011 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 4054587
16 September 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 689052
24 August 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 477383

Deficiency record · 27

07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 26 July 2024 Resolved
To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shut off valve must be fitted on any fuel line that supplies fuel to a propulsion engine or generator prime mover. Wire rope failed to operate fuel shut-off valves each time the pull station was activated. 46 CFR 143.260(a)
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 23 August 2024
Resolved 29 July 2024
Resolution: Witnessed satisfactory operation of remote fuel shutoffs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 July 2024 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and operating conditions. Inspection team observed missing cover on electrical box for Port Engine. 46 CFR 143.205(a)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2024
Resolved 31 July 2024
Resolution: Received photos correcting deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 26 July 2024 Resolved
All lifesaving equipment must be tested and maintained in accordance with the minimum requirements of 199.190. Bouyant apparatus on aft deck was not properly labled with vessel name in block letters.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2024
Resolved 31 July 2024
Resolution: Received photos correcting deficiencies.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 15 May 2023 Resolved
The master of a towing vessel must ensure that each crew member participates in fire-fighting drills and receives instruction at least once each month. The instruction may coincide with the drills, but is not required to do so. All crew members must be familiar with their fire-fighting duties, and, specifically how to: Fight a fire in the engine room and elsewhere on board the towing vessel, including how to: Stop any mechanical ventilation system for the engine room and effectively seal all natural openings to the space to prevent leakage of the extinguishing agent. During fire drill, vessel's crew was unfamiliar with how to secure engine room ventilation. Additionally, emergency procedures on board did not list procedure for securing engine room ventilation. Conduct crew training, revise emergency procedures, and conduct satisfactory fire drill in the presence of an attending Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 May 2023
Resolution: Procedures updated.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 May 2023 Resolved
Each towing vessel must be equipped with at least one fire axe that is readily accessible for use from the exterior of the vessel. No fire axe was found on board. Place fire axe on vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2023
Resolved 17 May 2023
Resolution: New axe onboard
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 15 May 2023 Resolved
Each ship subject to the Bridge-to-Bridge Act must have on board a radio operator who holds a restricted radiotelephone operator permit or higher class license. Neither Master or Apprentice Mate onboard had proof of a radio operator permit. Cite: 47 CFR 80.163
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2023
Resolved 17 May 2023
Resolution: Mastered showed proof of enrollment
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 15 May 2023 Resolved
The Coast Guard will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners. Master onboard was unable to provide a valid medical certificate when requested by Marine Inspectors. Master to provide necessary certificate at next inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2023
Resolved 17 May 2023
Resolution: Medical cert on board
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 26 April 2023 Resolved
To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover. When Marine Inspectors requested operational test of emergency fuel-oil cut-off, the connecting cable sheered, rendering system inoperable. Replace sheered cable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 May 2023
Resolution: Fuel shut off repaired.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 April 2023 Resolved
The portable fire pump must be self-priming and power-driven, with: (1) A minimum capacity of at least 300 LPM (80 gpm) at a discharge gauge pressure of not less than 414 kPa (60 psi), measured at the pump discharge. The portable fire pump on-board was inoperable. Complete necessary maintenance and operationally test in the presence of an attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 May 2023
Resolution: Completed maintenance and operationally tested in presence of Marine Inspector.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 26 April 2023 Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. Marine Inspectors observed 02 wasted weather-tight hatches leading to the vessel's bunk room.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 May 2023
Resolution: Completed repairs. Inspected satisfactorily.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 26 April 2023 Resolved
A towing vessel must carry adequate and up-to-date charts, maps, and nautical publications for the intended voyage. Vessel did not have 2023 coast pilot or Coast Guard light list. Vessel to have applicable parts of both publications for intended voyages.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 May 2023
Resolution: Pubs on board.
10 - Safety of Navigation › N/A - No Subsystem › Revolution counter
Issued 26 April 2023 Resolved
Each towing vessel must have a means to monitor and control the amount of thrust, rudder angle, and (if applicable) direction of thrust, at each operating station. Marine Inspectors found the port main engine RPM gauge to be disconnected; reinstall RPM gauge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2023
Resolved 15 May 2023
Resolution: RPM gauge reinstalled and operationally tested while underway for drills.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 26 April 2023 Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. Additionally, alarms must be visible and audible at each operating station. The system designations on the operating station alarm indicating panel were faded and/or not properly marked.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2023
Resolved 17 May 2023
Resolution: Alarms properly labeled
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 26 April 2023 Resolved
A towing vessel subject to this section must maintain a TVR, the TVR must include a chronological record of events as required by this subchapter. Vessel did not have consistent records and inspectors could not confirm all records have been kept. Vessel to maintain records in accordance with subchapter M, after 90 days vessel to submit to inspectors at MSU Texas City a copy of their records.
Action required: 705 - Other - as specified
Due 25 July 2023
Resolved 11 September 2023
Resolution: 07SEP2023 - attended vessel and reviewed official logbook entries/drill records. Required company to gather all vessel employees and discuss TVR requirements. Company meeting completed 08SEP2023 as well as Fire & MOB drills. See activity #7786060.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 23 February 2022 Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards and to ensure the following: all bilges are kept free from accumulation of combustible and flammable materials and liquids.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 March 2022
Resolved 15 March 2022
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 25 November 2020 Resolved
Lifefloat must be fitted with lifeline, pendants, a painter, and a floating electric water light. Lifefloat does not have attached painter with appropriate weak link attached or floating water light.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 December 2020
Resolution: Life float properly attached to vessel with painter and weak link and provided with a floating water light.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 November 2020 Resolved
The frame or support of any semi-portable fire extinguisher fitted with wheels must be welded or otherwise permanently attached to a steel bulkhead or deck to prevent it from rolling under heavy sea conditions. The Semi-portable fire extinguisher is not permanently attached the bulkhead or deck.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 December 2020
Resolution: Clip for semi-portable extinguisher installed on back deck to secure the extinguisher.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 25 November 2020 Resolved
To stop the flow of fuel in the event of a fire or rupture, a remote fuel shutoff valves must be fitted on fuel lines supplying propulsion engine or generator. It must be installed directly outside of the fuel tank and be operable from a safe place outside the space. Vessel does not have a remote fuel shutoff.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 December 2020
Resolution: Remote fuel cutoff installed on each of the two lines coming from fuel tank. Tested satisfactorily. Instructed crew to appropriately label the fuel cutoff.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 November 2020 Resolved
Vessel requested a maximum count of 06 persons on board and only has 03 lifejackets. Provide 06 total lifejackets to meet COI manning of a maximum capacity of 06 persons on board.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 December 2020
Resolution: 06 lifejackets provided onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 November 2020 Resolved
The water light must be attached by the lanyard with a corrosion resistant clip to allow the water light to be quickly disconnected from the lifebuoy. The clip must have strength of at least 22.7 kilograms (50 pounds). Neither one of the two lifebuoys had a lanyard attached with a corrosion resistant clip
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 December 2020
Resolution: Lights provided with appropriate line and clip. Instructed to attach around body of lifebuoy instead of to pendant lines.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 25 November 2020 Resolved
Each towing vessel must have reliable means to provide notification when an emergency condition exits or an essential system develops problems that required attention. The generator spaces did not have a high bilge alarm.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 December 2020
Resolution: Bilge alarm installed in Generator space and tested.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 November 2020 Resolved
Means must be provided for for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into engine spaces. There is no means of closing the ventilation to engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2020
Resolved 8 December 2020
Resolution: Plate provided and installed to allow for closure of engine room natural ventilation.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 25 November 2020 Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. Port and starboard main deckhouse doors and engine room door were missing dogs, corrosion/wastage on the metal channels guiding the gasket on each door, and doors did not seat properly when dogged down.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2020
Resolved 8 February 2021
Resolution: Doors tested and dog properly.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 25 November 2020 Resolved
An exposed hazard such as gears and rotating machinery, must be protected by a cover, guard or rail. Vessel needs guards on the shafts, fan between ER and generator room, and on both main engines.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2020
Resolved 8 February 2021
Resolution: Guards were put in place as required.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 November 2020 Resolved
Towing vessels 65 feet or less in length may meet the requirements listed in 33 CFR 183.810 or paragraph (a) of this section. Vessels navigation lights mast was bent leading the lights to no longer meet the arc of visibility requirements.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2020
Resolved 8 December 2020
Resolution: Mast straightened so lights appropriately meet visibility requirements.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 November 2020 Resolved
Fire hazards must be minimized and bilges kept clear of flammable or combustible materials. Steering gear pipes in ER had 02 minor leaks and was wrapped in absorbent pad. Repair leaking fittings.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2020
Resolved 8 December 2020
Resolution: Steering gear system joint resealed to stop leak.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 October 2020 Resolved
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. The vessel shall be made available for a Coast Guard COI inspection within 90 days. If an inspection is not completed prior to this date, the action for this deficiency shall be changed to a 60 (Rectify deficiencies prior to movement) and the vessel may no longer be permitted to operate.
Action required: 705 - Other - as specified
Due 20 October 2020
Resolved 26 October 2020
Resolution: Received worksite exclusion permit.