MARVEL FALCON is a 2018 tank ship. The Coast Guard has recorded 16 inspections since 2018, most recently in July 2026, along with 5 deficiencies and 1 operational control.

Records from 2018 to 2026. Most recent: inspection, 16 July 2026.

Built
2018
Last inspected
16 July 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 16 July 2026
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2018–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9760768
9V5057
1492338
Flag
SINGAPORE
Maury page id
psix-1492338

Documentation record

Tonnage as PSIX records it114084 - Convention (Subpart B), Gross Ton
89432 - Dead Weight, Metric Ton
37925 - Convention (Subpart B), Net Ton
123537 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 16

16 July 2026 COC-GAS Annual
Type not classified · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8439546
15 December 2025 Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8283881
21 July 2025 COC-GAS Renew · PSC B
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8183281
27 June 2024 COC-GAS Annual · PSC B
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7938586
8 January 2024 Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7846452
1 June 2023 COC-GAS Renew · PSC B
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7696521
2 May 2022 PSC B · COC-GAS Annual
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7435948
1 May 2022 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7442189
30 March 2021 COC-GAS Renew · PSC B
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7160627
25 February 2021 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7144765
27 January 2020 Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6897094
16 December 2019 ISPS II Exam · COC-GAS Annual · Ballast Water Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6870388
15 December 2018 ISPS II Exam · COC-GAS Renew · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6594403
9 December 2018 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6594410
17 May 2018 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6483293
16 May 2018 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6415784

Deficiency record · 5

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 30 March 2021 Resolved
06199-Other(Cargo)-Gas detection equipment shall be so designed that it may readily be tested. Gas Engineer was not following vessel's work instructions to test & calibrate the Gas Sample System as per ships SMS procedures. 74 SOLAS (14) VII/13.1 ICG Code (1993)/13.6.6
Action required: 10 - Deficiency Rectified
Resolved 30 March 2021
Resolution: Provided traiing and guidance to follow ship procedures for testing
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 March 2021 Resolved
07199-Other (Fire Safety)-Electrical installations shall be in accordance with recognized standards (IEC). PSCO officer observed 01 electrical light fixtures without the device capable of maintaining the integrity of the closure. 74 SOLAS (14) VII/13.1 IGC Code (1993)/10.1.3
Action required: 10 - Deficiency Rectified
Resolved 30 March 2021
Resolution: Vessel provided proper rated closure device and installed
12 - Dangerous Goods › N/A - No Subsystem › Instrumentation
Issued 17 December 2019 Resolved
Gas detection equipment should be so designed that it may readily be tested. During annual exam vessels crew unable to demonstrate fixed gas sampling operation for gas detection or alarms required at 30% LEL.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 18 December 2019
Resolved 27 January 2020
Resolution: Reviewed ABS class report and witnessed calibration and LEL sensor test (operational test); all test satisfactory.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 17 December 2019 Resolved
The company should establish procedures plans and instructions, including checklists as appropriate for key shipboard operations concerning the safety of the personnel, ship and protection of the environment. vessels crew unable to provide procedures for testing the fixed gas sampling system.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 18 December 2019
Resolved 27 January 2020
Resolution: Reviewed NKK class report and verified vessel had procedures onboard for operational test of Gas Detection; witnessed crew proficiency conducting operational test; all test satisfactory.
12 - Dangerous Goods › N/A - No Subsystem › Other (tankers)
Issued 17 December 2019 Resolved
Where tanks or piping are separated from the ships structure by thermal isolation provision should be made for electrically bonding both piping & tanks. Found 03 broken bonding cables on multiple cargo vapor lines in cargo compressor room.
Action required: 10 - Deficiency Rectified
Due 17 December 2019
Resolved 17 December 2019

Ownership record