Registered dimensions (L × B × D)51.5 ft × 15.0 ft × 9.5 ft
Registered tonnagegross 36 / net 33
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLARGO FL, UNITED STATES · built 1975
Hull materialFRP (Fiberglass)
PropulsionAuxiliary Sail
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portST PETE BEACH, FL
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 22 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it36 - Regulatory (Subpart C or D), Gross Ton
33 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
18 inspections, each with its date, unit and type; 16 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 18
13 May 2026
COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8372645
7 August 2025
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8197264
12 December 2024
Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8039202
5 March 2024
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7864183
20 June 2023
In-Service Inspection · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7719023
24 February 2023
Annual Inspection · Plan Review "T" Boat
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7641334
6 December 2022
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7591287
25 May 2022
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7477316
14 May 2021
COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7190391
1 December 2020
Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7093416
10 August 2020
Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7023959
12 August 2019
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6774509
5 September 2018
In-Service Inspection · Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6563201
19 June 2018
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6421341
10 May 2017
DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6126506
15 December 2016
Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6033203
29 September 2016
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5998537
11 May 2016
DAPI Audit · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5874535
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 June 2026
Resolved
A vessel must carry one floating water light. Vessel life ring buoy had an expired battery on its floating light. Replace battery.
46 CFR 180.70 (d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2026
Resolved 2 June 2026
Resolution: Received Pictures of new batteries installed on floating light for MAGIC.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 June 2026
Resolved
A power-driven vessel underway shall exhibit: (iii) Sidelights. Forward Navigation Lights had faded lens preventing 2 Nautical Mile illumination. Replace lens to ensure 2 miles visibility.
33 CFR 82.23 (a)(iii)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2026
Resolved 12 June 2026
Resolution: Received new Nav Light Lens replacement picture.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 13 May 2026
Resolved
A vessel must undergo an inspection for certification as specified in 176.404 and They must submit a written application for renewal of a Certificate of Inspection to the OCMI at least 30 days prior to the expiration date of the Certificate of Inspection. Vessel was due for COI renewal inspection on 14MAY2026 and has yet to submit an application for inspection, nor receive a COI inspection. Vessel shall not operate with passengers until new COI has been issued.
Action required: 705 - Other - as specified
Due 1 June 2026
Resolved 1 June 2026
Resolution: Completed COI Renewal. Issued new COI with 01JUN2031 Expiration date.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 December 2024
Resolved
46 CFR 177.330
The design, materials, and construction of masts, posts, yards, booms, bowsprits, and standing rigging on a sailing vessel must be suitable for the intended service. MI observed that boom mounting screws on the main and mizzen masts are starting to be pulled from mounting holes.
CODE 705: Vessel is prohibited from using sails with passengers on board until boom mounts have been inspected.
Action required: 705 - Other - as specified
Due 12 December 2024
Resolved 18 December 2024
Resolution: Boom mounts were tightened and determined to be structurally sound by a third party rigging inspector.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 March 2024
Resolved
The minimum number of portable fire extinguishers required on a vessel must be not less than the minimum number required by table 181.500(a).
One extinguisher was not charged; corrected on the spot.
46 CFR 181.500(a)
Action required: 10 - Deficiency Rectified
Due 5 March 2024
Resolved 5 March 2024
Resolution: Extinguisher replaced on the spot.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 5 March 2024
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating.
Fwd and port machinery space visual alarms inoperable.
46 CFR 182.530(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2024
Resolved 5 March 2024
Resolution: Alarms operate SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 August 2019
Resolved
All cable and wire must: be installed with metal supports spaced not more than 24 inches apart, and in such a manner as to avoid chafing and other damage. Wire runs throughout the engine room were supported by plastic wire ties. Replace with metal supports that avoid chafing. 46CFR183.340(b)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2019
Resolved 23 August 2019
Resolution: Vessel owner secured wires throughout the engine room with metal supports with protection from chafing.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 August 2019
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each of the unmanned spaces. The vessel had two lights provided for high water levels in the vessel, however there was no indication of which spaces each light was for. Label the lights. 46CFR182.530(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2019
Resolved 23 August 2019
Resolution: Vessel owner labeled the visual high water level indications at the operating station.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 August 2019
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. There was no visual indication at the operating station when the three automatic bilge pumps were operating. Provide visual indication.
46CFR182.530(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2019
Resolved 23 August 2019
Resolution: Vessel owner installed three new visual indicators at the operating station to show automatic bilge pump operation.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 12 August 2019
Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel. There was no placard posted near the VHF radio installation. 46CFR184.506
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2019
Resolved 25 September 2019
Resolution: Vessel placed placard above the VHF radio at the operating station.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 12 August 2019
Resolved
The EPIRB test required by paragraph (a) shall be logged 46CFR185.728(c) or otherwise documented, as applicable. There was no record of the testing of the EPIRB. Provide a template for recording test and begin testing EPIRB monthly. 46CFR185.728(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2019
Resolved 25 September 2019
Resolution: New line item added to preventative maintenance log requiring monthly inspection of EPIRB.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 June 2018
Resolved
Provide proof employees have read and signed company drug testing policy. Provide copy of policy. 46 CFR 16
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2018
Resolved 3 July 2018
Resolution: Verified employees have read and signed policy.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 June 2018
Resolved
Provide proof employees have received EAP training. 46 CFR 16
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2018
Resolved 3 July 2018
Resolution: Verified employees have received training.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 10 May 2017
Resolved
Faulty audible and visible alarm for pre-engineered fixed gas fire extinguishing system for vessel's machinery space. 46 CFR 181.420
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2017
Resolution: Corrected on the spot by replacing the audible and visible alarm in kind.
Engineering › Diesel Engine (propulsion-direct drive) › Bearing
Issued 29 September 2016
Resolved
Renew/replace shaft bearing. current bearing is beyond 50% wastage. 46CFR 176.610
Action required: 705 - Other - as specified
Resolved 6 October 2016
Resolution: Aft shaft bearing was replaced.
Electrical › Electric Supply System (service) › Battery Charger
Issued 17 May 2016
Resolved
Batter charger terminal connections exposed. Install cover IAW 46 CFR 183.340(g)
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 17 May 2016
Resolution: Installed cover over terminal connections.