← All vessels
MAGIC
Passenger (Inspected) · Passenger Ship class · Built 1970s · USCG Southeast District (CGD-SE) · Other hulls named MAGIC
MAGIC is a 1975 passenger vessel (inspected). The Coast Guard has recorded 42 inspections since 2000, most recently in May 2026, along with 30 deficiencies.
Records from 2000 to 2026. Most recent: inspection, 13 May 2026.
- Built
- 1975
- Last inspected
- 13 May 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 30 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
582060
WDG4170
149282
Flag
UNITED STATES
367533730
Maury page id
psix-149282
Inspections, by type
…with no type recorded1
Years with a record
25 calendar years (2000–2026)
The 42 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)51.5 ft × 15.0 ft × 9.5 ft
Registered tonnagegross 36 / net 33
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · LARGO FL, UNITED STATES · built 1975
Hull materialFRP (Fiberglass)
PropulsionAuxiliary Sail
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portST PETE BEACH, FL
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 22 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it36 - Regulatory (Subpart C or D), Gross Ton
33 - Regulatory (Subpart C or D), Net Ton
33 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDG4170MMSI 367533730 · active · compulsorily equipped · granted 6 May 2022, expires 5 June 2032
WDHDMMSI 366838670 · expired · compulsorily equipped · granted 12 February 2002, cancelled 14 April 2012
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 42
13 May 2026
COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8372645
7 August 2025
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8197264
12 December 2024
Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8039202
5 March 2024
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7864183
20 June 2023
In-Service Inspection · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7719023
24 February 2023
Annual Inspection · Plan Review "T" Boat
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7641334
6 December 2022
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7591287
25 May 2022
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7477316
14 May 2021
COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7190391
1 December 2020
Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7093416
10 August 2020
Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7023959
12 August 2019
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6774509
5 September 2018
In-Service Inspection · Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6563201
19 June 2018
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6421341
10 May 2017
DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6126506
15 December 2016
Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6033203
29 September 2016
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5998537
11 May 2016
DAPI Audit · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5874535
7 August 2015
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5208904
2 October 2014
Internal Structural Exam · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4997205
15 August 2014
DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4954624
21 June 2012
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4351129
31 January 2012
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4235353
8 October 2010
Administrative Inspection · Hull Examination · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3882455
20 July 2009
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3540157
4 November 2008
Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3359044
8 July 2008
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3261200
10 July 2007
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2990181
19 May 2006
COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2647723
19 August 2005
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2458373
4 March 2005
Plan Review "T" Boat
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2504853
11 November 2004
Deficiency Check · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2235140
11 September 2004
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2197133
6 May 2004
Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2060646
27 June 2003
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1826719
8 November 2002
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1704212
1 October 2002
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1681044
24 August 2001
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1071708
8 June 2001
Initial Certification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1382281
8 May 2001
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1063544
26 April 2001
Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1061697
4 October 2000
Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 823440
Deficiency record · 30
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 June 2026
Resolved
A vessel must carry one floating water light. Vessel life ring buoy had an expired battery on its floating light. Replace battery.
46 CFR 180.70 (d)
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 June 2026
Resolved
A power-driven vessel underway shall exhibit: (iii) Sidelights. Forward Navigation Lights had faded lens preventing 2 Nautical Mile illumination. Replace lens to ensure 2 miles visibility.
33 CFR 82.23 (a)(iii)
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 13 May 2026
Resolved
A vessel must undergo an inspection for certification as specified in 176.404 and They must submit a written application for renewal of a Certificate of Inspection to the OCMI at least 30 days prior to the expiration date of the Certificate of Inspection. Vessel was due for COI renewal inspection on 14MAY2026 and has yet to submit an application for inspection, nor receive a COI inspection. Vessel shall not operate with passengers until new COI has been issued.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 December 2024
Resolved
46 CFR 177.330
The design, materials, and construction of masts, posts, yards, booms, bowsprits, and standing rigging on a sailing vessel must be suitable for the intended service. MI observed that boom mounting screws on the main and mizzen masts are starting to be pulled from mounting holes.
CODE 705: Vessel is prohibited from using sails with passengers on board until boom mounts have been inspected.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 March 2024
Resolved
The minimum number of portable fire extinguishers required on a vessel must be not less than the minimum number required by table 181.500(a).
One extinguisher was not charged; corrected on the spot.
46 CFR 181.500(a)
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 5 March 2024
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating.
Fwd and port machinery space visual alarms inoperable.
46 CFR 182.530(c)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 August 2019
Resolved
All cable and wire must: be installed with metal supports spaced not more than 24 inches apart, and in such a manner as to avoid chafing and other damage. Wire runs throughout the engine room were supported by plastic wire ties. Replace with metal supports that avoid chafing. 46CFR183.340(b)(4)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 August 2019
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each of the unmanned spaces. The vessel had two lights provided for high water levels in the vessel, however there was no indication of which spaces each light was for. Label the lights. 46CFR182.530(a)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 August 2019
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. There was no visual indication at the operating station when the three automatic bilge pumps were operating. Provide visual indication.
46CFR182.530(c)
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 12 August 2019
Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel. There was no placard posted near the VHF radio installation. 46CFR184.506
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 12 August 2019
Resolved
The EPIRB test required by paragraph (a) shall be logged 46CFR185.728(c) or otherwise documented, as applicable. There was no record of the testing of the EPIRB. Provide a template for recording test and begin testing EPIRB monthly. 46CFR185.728(c)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 June 2018
Resolved
Provide proof employees have read and signed company drug testing policy. Provide copy of policy. 46 CFR 16
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 June 2018
Resolved
Provide proof employees have received EAP training. 46 CFR 16
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 10 May 2017
Resolved
Faulty audible and visible alarm for pre-engineered fixed gas fire extinguishing system for vessel's machinery space. 46 CFR 181.420
Engineering › Diesel Engine (propulsion-direct drive) › Bearing
Issued 29 September 2016
Resolved
Renew/replace shaft bearing. current bearing is beyond 50% wastage. 46CFR 176.610
Electrical › Electric Supply System (service) › Battery Charger
Issued 17 May 2016
Resolved
Batter charger terminal connections exposed. Install cover IAW 46 CFR 183.340(g)
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 7 August 2015
Resolved
Install belt guard over rotating machinery (belt and pulley) on main engine. 46 CFR 177.960
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 19 August 2005
Resolved
PROVIDE 7 ADDITIONAL ADULT TYPE I LIFEJACKETS. TOTAL PERSONS REDUCED TO 38 UNTIL ACCOMPLISHED.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 19 August 2005
Resolved
CONNECT FORCED VENTILLATION IN ENGINE ROOM TO FIXED FIRE FIGHTING SYSTEM SHUT DOWN OR BYPASS AND DISCONNECT BLOWER SYSTEM.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 2 November 2004
Resolved
PROVIDE 3RD PARTY RIGGING REPORT.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 11 September 2004
Resolved
Owner failed to make vessel available for annual inspection w/in 3 months before or after each anniversary date of issuance of the COI
Lifesaving › Lifejacket/PFD (Type I)
Issued 1 October 2002
Resolved
PROPERLY LABEL LIFEJACKET STOWAGE AREAS. ENSURE CHILD LIFEJACKETS ARE LISTED SEPERATELY, PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: Storage
Fire Fighting › Remote Fuel Shutoff
Issued 1 October 2002
Resolved
PROPERLY STENCIL REMOTE FUEL SHUTOFF PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: Marking
Engineering › Bilge Water Management System
Issued 1 October 2002
Resolved
REPLACE FLOAT SWITCH ON HIGH LEVEL ALARM PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: Alarm
Engineering › Bilge Water Management System
Issued 1 October 2002
Resolved
REPAIR ON/OFF SWITCH FOR HIGH LEVEL ALARM PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: Power Switch
Navigation › Collision/Grounding Avoidance
Issued 1 October 2002
Resolved
PROVIDE BELL PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: Bell
Operations/Management › Lifesaving
Issued 1 October 2002
Resolved
MODIFY LADDER TO MORE EASILY ASSIST IN RETRIEVAL OF HELPLESS PERSON FROM THE WATER. LEGACY COMPONENT DESC: Op Readiness/Maintenance/Inspection
Lifesaving
Issued 8 June 2001
Resolved
PRIOR TO CARRIAGE OF PASSENGERS, INSTALL TEMPORARY MANUALLY ACTUATED LIGHTING IN VESSEL HEAD AND ESCAPE ROUTE.
Lifesaving
Issued 8 June 2001
Resolved
CONDUCT UNDERWAY DRILLS.
Lifesaving
Issued 8 June 2001
Resolved
INSTALL AUTOMATICALLY ACTUATED EMERGENCY LIGHTING TO ILLUMINATE EMERGENCY ESCAPE ROUTE.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.