MAURY USCG vessel records Sign in
← All vessels

MAGIC

MAGIC is a 1975 passenger vessel (inspected). The Coast Guard has recorded 42 inspections since 2000, most recently in May 2026, along with 30 deficiencies.

Records from 2000 to 2026. Most recent: inspection, 13 May 2026.

Built
1975
Last inspected
13 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDG4170
149282
Flag
UNITED STATES
367533730
Maury page id
psix-149282

Inspections, by type

…with no type recorded1
Years with a record 25 calendar years (2000–2026)
The 42 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)51.5 ft × 15.0 ft × 9.5 ft
Registered tonnagegross 36 / net 33
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · LARGO FL, UNITED STATES · built 1975
Hull materialFRP (Fiberglass)
PropulsionAuxiliary Sail
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portST PETE BEACH, FL
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 22 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it36 - Regulatory (Subpart C or D), Gross Ton
33 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDG4170MMSI 367533730 · active · compulsorily equipped · granted 6 May 2022, expires 5 June 2032
WDHDMMSI 366838670 · expired · compulsorily equipped · granted 12 February 2002, cancelled 14 April 2012
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 42

13 May 2026 COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8372645
7 August 2025 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8197264
12 December 2024 Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8039202
5 March 2024 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7864183
20 June 2023 In-Service Inspection · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7719023
24 February 2023 Annual Inspection · Plan Review "T" Boat
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7641334
6 December 2022 Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7591287
25 May 2022 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7477316
14 May 2021 COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7190391
1 December 2020 Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7093416
10 August 2020 Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7023959
12 August 2019 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6774509
5 September 2018 In-Service Inspection · Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6563201
19 June 2018 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6421341
10 May 2017 DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6126506
15 December 2016 Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6033203
29 September 2016 Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5998537
11 May 2016 DAPI Audit · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5874535
7 August 2015 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5208904
2 October 2014 Internal Structural Exam · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4997205
15 August 2014 DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4954624
21 June 2012 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4351129
31 January 2012 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4235353
8 October 2010 Administrative Inspection · Hull Examination · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3882455
20 July 2009 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3540157
4 November 2008 Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3359044
8 July 2008 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3261200
10 July 2007 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2990181
19 May 2006 COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2647723
19 August 2005 Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2458373
4 March 2005 Plan Review "T" Boat
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2504853
11 November 2004 Deficiency Check · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2235140
11 September 2004 Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2197133
6 May 2004 Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2060646
27 June 2003 Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1826719
8 November 2002 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1704212
1 October 2002 Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1681044
24 August 2001 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1071708
8 June 2001 Initial Certification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1382281
8 May 2001 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1063544
26 April 2001 Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1061697
4 October 2000 Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 823440

Deficiency record · 30

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 June 2026 Resolved
A vessel must carry one floating water light. Vessel life ring buoy had an expired battery on its floating light. Replace battery. 46 CFR 180.70 (d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2026
Resolved 2 June 2026
Resolution: Received Pictures of new batteries installed on floating light for MAGIC.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 June 2026 Resolved
A power-driven vessel underway shall exhibit: (iii) Sidelights. Forward Navigation Lights had faded lens preventing 2 Nautical Mile illumination. Replace lens to ensure 2 miles visibility. 33 CFR 82.23 (a)(iii)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2026
Resolved 12 June 2026
Resolution: Received new Nav Light Lens replacement picture.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 13 May 2026 Resolved
A vessel must undergo an inspection for certification as specified in 176.404 and They must submit a written application for renewal of a Certificate of Inspection to the OCMI at least 30 days prior to the expiration date of the Certificate of Inspection. Vessel was due for COI renewal inspection on 14MAY2026 and has yet to submit an application for inspection, nor receive a COI inspection. Vessel shall not operate with passengers until new COI has been issued.
Action required: 705 - Other - as specified
Due 1 June 2026
Resolved 1 June 2026
Resolution: Completed COI Renewal. Issued new COI with 01JUN2031 Expiration date.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 December 2024 Resolved
46 CFR 177.330 The design, materials, and construction of masts, posts, yards, booms, bowsprits, and standing rigging on a sailing vessel must be suitable for the intended service. MI observed that boom mounting screws on the main and mizzen masts are starting to be pulled from mounting holes. CODE 705: Vessel is prohibited from using sails with passengers on board until boom mounts have been inspected.
Action required: 705 - Other - as specified
Due 12 December 2024
Resolved 18 December 2024
Resolution: Boom mounts were tightened and determined to be structurally sound by a third party rigging inspector.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 March 2024 Resolved
The minimum number of portable fire extinguishers required on a vessel must be not less than the minimum number required by table 181.500(a). One extinguisher was not charged; corrected on the spot. 46 CFR 181.500(a)
Action required: 10 - Deficiency Rectified
Due 5 March 2024
Resolved 5 March 2024
Resolution: Extinguisher replaced on the spot.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 5 March 2024 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Fwd and port machinery space visual alarms inoperable. 46 CFR 182.530(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2024
Resolved 5 March 2024
Resolution: Alarms operate SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 August 2019 Resolved
All cable and wire must: be installed with metal supports spaced not more than 24 inches apart, and in such a manner as to avoid chafing and other damage. Wire runs throughout the engine room were supported by plastic wire ties. Replace with metal supports that avoid chafing. 46CFR183.340(b)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2019
Resolved 23 August 2019
Resolution: Vessel owner secured wires throughout the engine room with metal supports with protection from chafing.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 August 2019 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each of the unmanned spaces. The vessel had two lights provided for high water levels in the vessel, however there was no indication of which spaces each light was for. Label the lights. 46CFR182.530(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2019
Resolved 23 August 2019
Resolution: Vessel owner labeled the visual high water level indications at the operating station.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 August 2019 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. There was no visual indication at the operating station when the three automatic bilge pumps were operating. Provide visual indication. 46CFR182.530(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2019
Resolved 23 August 2019
Resolution: Vessel owner installed three new visual indicators at the operating station to show automatic bilge pump operation.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 12 August 2019 Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel. There was no placard posted near the VHF radio installation. 46CFR184.506
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2019
Resolved 25 September 2019
Resolution: Vessel placed placard above the VHF radio at the operating station.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 12 August 2019 Resolved
The EPIRB test required by paragraph (a) shall be logged 46CFR185.728(c) or otherwise documented, as applicable. There was no record of the testing of the EPIRB. Provide a template for recording test and begin testing EPIRB monthly. 46CFR185.728(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2019
Resolved 25 September 2019
Resolution: New line item added to preventative maintenance log requiring monthly inspection of EPIRB.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 June 2018 Resolved
Provide proof employees have read and signed company drug testing policy. Provide copy of policy. 46 CFR 16
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2018
Resolved 3 July 2018
Resolution: Verified employees have read and signed policy.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 June 2018 Resolved
Provide proof employees have received EAP training. 46 CFR 16
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2018
Resolved 3 July 2018
Resolution: Verified employees have received training.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 10 May 2017 Resolved
Faulty audible and visible alarm for pre-engineered fixed gas fire extinguishing system for vessel's machinery space. 46 CFR 181.420
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2017
Resolution: Corrected on the spot by replacing the audible and visible alarm in kind.
Engineering › Diesel Engine (propulsion-direct drive) › Bearing
Issued 29 September 2016 Resolved
Renew/replace shaft bearing. current bearing is beyond 50% wastage. 46CFR 176.610
Action required: 705 - Other - as specified
Resolved 6 October 2016
Resolution: Aft shaft bearing was replaced.
Electrical › Electric Supply System (service) › Battery Charger
Issued 17 May 2016 Resolved
Batter charger terminal connections exposed. Install cover IAW 46 CFR 183.340(g)
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 17 May 2016
Resolution: Installed cover over terminal connections.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 7 August 2015 Resolved
Install belt guard over rotating machinery (belt and pulley) on main engine. 46 CFR 177.960
Due 7 September 2015
Resolved 4 September 2015
Resolution: Belt guard installed.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 19 August 2005 Resolved
PROVIDE 7 ADDITIONAL ADULT TYPE I LIFEJACKETS. TOTAL PERSONS REDUCED TO 38 UNTIL ACCOMPLISHED.
Due 19 September 2005
Resolved 8 September 2005
Resolution: Corrected
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 19 August 2005 Resolved
CONNECT FORCED VENTILLATION IN ENGINE ROOM TO FIXED FIRE FIGHTING SYSTEM SHUT DOWN OR BYPASS AND DISCONNECT BLOWER SYSTEM.
Due 19 September 2005
Resolved 8 September 2005
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 2 November 2004 Resolved
PROVIDE 3RD PARTY RIGGING REPORT.
Due 2 December 2004
Resolved 9 November 2004
Resolution: FAX DOCUMENTATION.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 11 September 2004 Resolved
Owner failed to make vessel available for annual inspection w/in 3 months before or after each anniversary date of issuance of the COI
Due 11 September 2004
Resolved 11 September 2004
Resolution: Inspector attended vessel on Saturday to conduct reinspeciton.
Lifesaving › Lifejacket/PFD (Type I)
Issued 1 October 2002 Resolved
PROPERLY LABEL LIFEJACKET STOWAGE AREAS. ENSURE CHILD LIFEJACKETS ARE LISTED SEPERATELY, PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: Storage
Due 8 October 2002
Resolved 8 November 2002
Resolution: CORRECTED.
Fire Fighting › Remote Fuel Shutoff
Issued 1 October 2002 Resolved
PROPERLY STENCIL REMOTE FUEL SHUTOFF PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: Marking
Due 8 October 2002
Resolved 8 November 2002
Resolution: CORRECTED.
Engineering › Bilge Water Management System
Issued 1 October 2002 Resolved
REPLACE FLOAT SWITCH ON HIGH LEVEL ALARM PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: Alarm
Due 8 October 2002
Resolved 8 November 2002
Resolution: REPAIRED AND TESTED.
Engineering › Bilge Water Management System
Issued 1 October 2002 Resolved
REPAIR ON/OFF SWITCH FOR HIGH LEVEL ALARM PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: Power Switch
Condition: Improper Installation
Due 8 October 2002
Resolved 8 November 2002
Resolution: REPAIRED AND TESTED.
Navigation › Collision/Grounding Avoidance
Issued 1 October 2002 Resolved
PROVIDE BELL PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: Bell
Condition: Improper Installation
Due 8 October 2002
Resolved 8 November 2002
Resolution: INSTALLED.
Operations/Management › Lifesaving
Issued 1 October 2002 Resolved
MODIFY LADDER TO MORE EASILY ASSIST IN RETRIEVAL OF HELPLESS PERSON FROM THE WATER. LEGACY COMPONENT DESC: Op Readiness/Maintenance/Inspection
Condition: Design Flaw
Due 1 November 2002
Resolved 8 November 2002
Resolution: INSTALLED AND TESTED. MODIFICATION BEING MADE TO STRENGHTHEN PLATFORM.
Lifesaving
Issued 8 June 2001 Resolved
PRIOR TO CARRIAGE OF PASSENGERS, INSTALL TEMPORARY MANUALLY ACTUATED LIGHTING IN VESSEL HEAD AND ESCAPE ROUTE.
Condition: Unknown
Due 8 June 2001
Resolved 8 June 2001
Lifesaving
Issued 8 June 2001 Resolved
CONDUCT UNDERWAY DRILLS.
Condition: Unknown
Due 8 June 2001
Resolved 8 June 2001
Lifesaving
Issued 8 June 2001 Resolved
INSTALL AUTOMATICALLY ACTUATED EMERGENCY LIGHTING TO ILLUMINATE EMERGENCY ESCAPE ROUTE.
Condition: Unknown
Due 8 June 2001
Resolved 8 June 2001

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.