PGC EIRINI is a 2018 tank ship. The Coast Guard has recorded 1 inspection in 2018, along with 3 deficiencies — 1 with no resolution recorded —.

Records in 2018. Most recent: inspection, 28 June 2018.

Built
2018
Last inspected
28 June 2018
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 28 June 2018
Operational controls None recorded without a removal date
Years with a record 1 calendar year (2018)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9800178
9HA4714
1493405
Flag
MALTA
Maury page id
psix-1493405

Documentation record

Tonnage as PSIX records it2164 - Convention (Subpart B), Net Ton
6602 - Dead Weight, Metric Ton
10830 - Displacement, Metric Ton
7211 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

1 inspection, each with its date, unit and type; 3 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 1

28 June 2018 Ballast Water Examination · COC-GAS Renew · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6451117

Deficiency record · 3

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 28 June 2018 Resolved
1870-Special Requirements- A gas carrier shall comply with the requirements of the international Gas Carrier Code. For the purpose of this regulation, the requirements of the code shall be treated as mandatory. Care should be taken to ensure that the cargo (BUTADIENE) is sufficiently inhibited to prevent polymerization at all times during the voyage. Ships should be provided with a certificate from the manufacturer. PSCO observed the Certificate of inhibitor was dated 05MAY2018 and valid for 01 month. Vessel is prohibited from cargo operations until clarification from shipper and class. SOLAS 74a (2014 Cons.) VII/13.1 IGC Code 17.8 ac
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 29 June 2018
Resolution: PSC NOLA received class report from NKK attesting to the Inhibitor being acceptable to all parties.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 June 2018 Resolved
0735- Personal equipment-fire fighting- Fire-fighter’s outfits shall comply with Fire Safety system code. All air cylinders for breathing apparatus shall be interchangeable. PSCO observed air cylinders for Fire Suit SCBAs and Chemical suit SCBAs were not interchangeable stored in the same location. SOLAS 74a (2014 Cons.) II-2/10.10.1 FSS Code Ch 3.2.1.2.1 16a
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 June 2018
Resolution: PSC NOLA received a class report stating SCBA bottles had been seperated and marked as different and FSS is not applicable as IGC does not have the requirement.
01 - Certificates & Documentation › 011 - Ships Certificates › INF certificate of fitness
Issued 28 June 2018 No resolution recorded
0131- Liquefied gas in bulk COF/BC-Code- A certificate called an international certificate of fitness for the carriage of liquefied gases in bulk, the model form of which is set out in the appendix, should be issued. COF list Ammonia and not Anhydrous Ammonia. SOLAS 74a (2014 Cons.) VII/13.1 IGC Code 1.5.4 50a
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days

Ownership record