← All vessels
SCENIC ECLIPSE
SCENIC ECLIPSE is a passenger vessel (inspected). The Coast Guard has recorded 8 inspections since 2018, most recently in October 2024, along with 22 deficiencies — 1 with no resolution recorded — and 1 operational control.
Records from 2018 to 2024. Most recent: operational control imposed, 9 October 2024.
- Built
- Not recorded
- Last inspected
- 9 October 2024
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 22 recorded · 1 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9797371 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
C6ET4
1494731
Flag
BAHAMAS, THE
—
Maury page id
psix-1494731
Inspections, by type
…with no type recorded1
…past their stated due date1
Years with a record
5 calendar years (2018–2024)
The 8 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Tonnage as PSIX records it2065 - Dead Weight, Metric Ton
17545 - Convention (Subpart B), Gross Ton
5263 - Convention (Subpart B), Net Ton
17545 - Convention (Subpart B), Gross Ton
5263 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 8
9 October 2024
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8016993
7 October 2024
PSC A
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8011629
26 June 2023
Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7723864
3 May 2023
COC-CVE Quarterly · PSC B · Ballast Water Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7672319
5 September 2022
PSC A · COC-CVE Annual
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7540988
21 October 2019
Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6838806
5 September 2019
ISPS II Exam · Ballast Water Examination · COC-CVE Initial · PII Safety Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6804462
8 May 2018
COC-CVE Initial Prep · COC-CVE Initial
Administrative · Activities Europe · Activity 6408743
Deficiency record · 22
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 7 October 2024
No resolution recorded
Safe escape routes shall be provided. PSCO observed the
executive chef room within the deck 4 galley without a safe
escape route to a stairway, nor an acceptable means to
notify crew normally employed in the space of a fire in the
surrounding space.
74 SOLAS 20 II-2/13.1.1
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 7 October 2024
Resolved
Escape routes shall be maintained in a safe condition, clear
of obstacles. PSCO observed benches and shoes stored in
crew accommodations corridors throughout deck 2.
74 SOLAS 20 II-2/13.1.2
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 7 October 2024
Resolved
Fire doors in main vertical zone bulkheads, galley
boundaries and stairway enclosures, the approximate time
of closure for hinged fire doors shall be no more than 40 s and no less than 10 s from the beginning of their movement.
PSCO observed the following doors close in less than 10
seconds: stairway fire door HFD5301, HFD3204, galley fire
doors HFD4404, HFD4407.
74 SOLAS 20 II-2/9.4.1.1.5.2
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 7 October 2024
Resolved
Fire doors in main vertical zone bulkheads, galley
boundaries and stairway enclosures shall be self-closing
and be capable of closing with an angle of inclination of up to 3.5° opposing closure. PSCO observed the following doors
did not fully latch closed: stairway fire door HFD 3201.
74 SOLAS 20 II-2/9.4.1.1.5.1
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 7 October 2024
Resolved
Escape routes shall be maintained in a safe condition, clear
of obstacles. PSCO observed storage box and crate
obstructing the escape route of main laundry.
74 SOLAS 20 II-2/13.1.2
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 7 October 2024
Resolved
The company should establish procedures to ensure that
the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional
requirements which may be established by the company. Ship has safety policy for crew to clean laundry dryer lint filters before and after use. PSCO observed lint filters in all three crew laundry dryers uncleaned.
74 SOLAS 20 IX/3.1
ISM Code A.10.1
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 October 2024
Resolved
Waste receptacles shall be constructed of non-combustible materials with no openings in the sides or bottom. PSCO observed two non-combustible waste receptacles in the main laundry marked for and containing plastic waste.
74 SOLAS 20 II-2/4.4.2
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 3 May 2023
Resolved
05199-(Other)Every company should develop, implement, and maintain a safety management system which includes the following functional requirements: Instructions and procedures to ensure safe operation of ships. Vessel failed to implement its SMS with respect to cyber risk management. Vessel's SMS instructs crew not to store passwords in files or on post-notes. Passwords were written, posted and displayed on multiple computers connected to the ship's network. Recommend internal audit to ensure SMS cyber hygiene implementation. 74 SOLAS (14) IX 13.1 ISM Code 1.4. 50ac
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 September 2022
Resolved
Waste receptacles shall be constructed of non-combustible materials. Waste receptacles throughout the ship, including several in the bathrooms on deck 10 were found to be plastic. 74 SOLAS 20 II-2/4.4.2
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 5 September 2022
Resolved
Means of escape from control stations, accommodation spaces and service spaces shall be maintained in a safe condition, clear of obstacles. PSCOs observed that garbage was being stored in a manner that blocked emergency means of escape from the incinerator room to garbage room on Deck 3. Additionally the emergency escape route from the helipad on Deck 8 was obstructed by stacked furniture. 74 SOLAS 20 II-2/13.1.1
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 September 2022
Resolved
Electrical installations shall be such that...the safety of passengers, crew, and ship from electrical hazards will be ensured. PSCO observed multiple extension cords being used in sequence to power television and other equipment in crew lounge on deck 3 forward. 74 SOLAS 20 II-1/40.1.2
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 September 2022
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate uses. During the fire drill, the charge hose used in the main stairway on deck 3 was identified to be leaking. 74 SOLAS 20 II-2/14.2.1.2
04 - Emergency Systems › N/A - No Subsystem › Low level lighting in corridors
Issued 5 September 2022
Resolved
The means of escape...shall be marked with lighting or photoluminescent strip indicators placed not more than 300 mm above the deck. It was observed that the low location lighting in the escape route from the helipad on deck 8 was blocked by stacked chairs by stacked chairs which had been stowed in the corridor while not in use. 74 SOLA 20 II-2/13.3.2.5.1
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 5 September 2019
Resolved
001-9800-Means shall be provide for bringing the davit launched survival craft against the ships side and holding them. Crew could no demonstrate proper launching during drill for safe embarkartion.-SOLAS 14/III Reg. 11.8-50AC
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 September 2019
Resolved
002-0750-Fire doors in main wertical zones shall be self closing. Fire doors would not close without assistance of electrical tape dampening magnets.-SOLAS 14/II-2 Reg.9.4.1.1.5.1-50AC
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 5 September 2019
Resolved
003-0750-Fire growth potenial in every space of the ship shall be limited. Means of control for flammable liquids in the space shall be provided. Gasoline containers and flammable liquids in bosun stores are improperly stored, and enginnering spaces.-SOLAS 17/II-2 Reg.5.1.2-10C
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 September 2019
Resolved
004-9800-Furniture in stairway enclosures shall be limited to fixed seating. 02 couches and security equipment located on Deck 4 passenger stairway.-SOLAS 14/II-2 Reg.5.3.3-50AC
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 5 September 2019
Resolved
005-0750-Pipe penetrations shall be suitably insulated. Pipes in bulkhead in propulsion drive room not insulated.-SOLAS 14/II-2 Reg. 9.3.1-10C
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 5 September 2019
Resolved
006-0915-Water tight doors with hand operated mechanisms shall have rotation clearly indicated at operating position. Water tight door in pod room has signage backwards.-SOLAS 14/II-1 Reg. 13.7.1.4-10C
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 September 2019
Resolved
007-0720-In passenger ships, at least one effective jet of water must be readily available from each hydrant. The nozzle was not connected to hose in forward port side equipment room.- SOLAS 14/II-2 Reg. 10.2.1.2.1.1-10C
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 5 September 2019
Resolved
008-9800-Safe escape routes shall be provided. Dressing room in theateris a "room in room" constrution with no acceptable means of escape or aubible alarms.-SOLAS 14/II-2 Reg.13.1.1-50AC
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 5 September 2019
Resolved
009-9800-Escape doors from public spaes that are normally latched shall be fitted with a means of quick release. Aft secondary escape from KoKos has a latch, but no release in the direction of escape.-SOLAS 14/II-2 Reg. 13.3.2.6.2-10C
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.