Records from 2017 to 2025. Most recent: inspection, 23 July 2025.
Documentation record
Registered dimensions (L × B × D)127.3 ft × 39.3 ft × 12.5 ft
Registered tonnagegross 94 / net 64
ITC dimensions (L × B × D)127.3 ft × 39.3 ft × 12.5 ft
ITC tonnagegross 622 / net 214
BuilderDAKOTA CREEK INDUSTRIES · ANACORTES, WA, UNITED STATES · built 2019
Hull materialAluminum
PropulsionJet Drive
Hull shapeShip
Hull configurationTwin Hull
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 6 July 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it622 - Convention (Subpart B), Gross Ton
94 - Regulatory (Subpart C or D), Gross Ton
214 - Convention (Subpart B), Net Ton
64 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 24
23 July 2025
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8212455
14 March 2025
Hull Examination · Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8093340
5 August 2024
Drydock Extension
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7975659
16 July 2024
Administrative Inspection · Deficiency Check · Internal Structural Exam · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7959562
12 March 2024
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7878116
27 September 2023
Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7798617
22 August 2023
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7774674
19 January 2023
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7624018
9 November 2022
Hull Examination · Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7591364
31 August 2022
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7541416
10 July 2022
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7502870
10 July 2022
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7510449
26 November 2021
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7357740
20 October 2021
Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7335608
17 June 2021
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7263559
23 March 2021
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7161439
19 November 2020
Internal Structural Exam · Deficiency Check · Hull Examination · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7098732
11 August 2020
Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7030330
27 April 2020
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6944609
6 April 2020
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6936053
17 March 2020
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6927980
26 October 2019
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6846195
20 August 2019
Administrative Inspection · Initial Certification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6789717
13 April 2017
Construction Oversight · COI Inspection · Deadweight Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6423935
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 14 March 2025
Resolved
An internal structural examination conducted in compliance with § 115.600...and consists of a complete examination of the vessel's main strength members, including the major internal framing. MI identified 02 fractured welds in port forepeak and identified a potential temporary repair to starboard forpeak between 3rd and 4th transverse frame.
46 CFR 115.610(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 April 2025
Resolution: See narrative
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 7 August 2024
Resolved
Each door, hatch, or scuttle, used as a means of escape, must be capable of being opened by one person, from either side, in both light and dark conditions. Access hatches to port and starboard jet rooms are secured on the weatherdeck by padlocks and incapable of being opened from inside the space when locked.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 August 2024
Resolution: Crew effected repairs that allow opening internally with external lock still in place.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 7 August 2024
Resolved
Each vessel must be provided with a visual and audible alarm at the operating station to indicate a high water level. High water alarm in port fuel void was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 7 August 2024
Resolution: Crew repaired high level alarm and proved operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 March 2024
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed, and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Operator reported issue with port gearbox and the vessel was removed from service to investigate further.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2024
Resolution: Port gearbox replaced and sea trialed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 September 2023
Resolved
Each life ring buoy must be marked in clearly legible block capital letters with the vessels name. 2nd deck aft ring buoy's letters are un-legible. Vessel to mark buoy to the satisfaction of the marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 October 2023
Resolved 12 October 2023
Resolution: Buoy marked to the satisfaction of the marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 September 2023
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets. All child life jacket locations on the 2nd deck are not marked correctly. Vessel to mark all locations correctly to the satisfaction of the marine inspector.
46 CFR 177.78(a)(5)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 October 2023
Resolved 12 October 2023
Resolution: All life jacket locations marked correctly to the satisfaction of the marine inspector.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 31 August 2022
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of electrical equipment and systems, including the following: Operational test of all emergency electrical systems. During inspection, public address system was not audible on second deck.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2022
Resolved 22 September 2022
Resolution: PA system working properly on 2nd deck.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 31 August 2022
Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. Engine rooms were found with bilges containing oil, sand, and trash. Additionally, loose tools were found in starboard engine room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2022
Resolved 20 September 2022
Resolution: Engine rooms were pressure washed and cleaned.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 31 August 2022
Resolved
Each item of lifesaving equipment carried on board a vessel but not required under this part, must be of an approved type meeting the specifications for lifesaving equipment in subchapter Q of this chapter, or other standard specified by the Commandant. Water lights attached to life ring buoys are not USCG approved.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2022
Resolved 20 September 2022
Resolution: Correct waterlights were placed onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 August 2022
Resolved
Commercial hybrid personal flotation devices (PFD) approved in accordance with §160.077 in subchapter Q of this chapter, or other standard specified by the Commandant, may be carried as additional equipment for use of persons working near or over the water. Each commercial hybrid PFD must be used, stowed, and maintained in accordance with the procedures set out in the manual required for these devices under § 160.077-29 in subchapter Q of this chapter and any limitation(s) marked on them; and of the same or smaller design and have the same method of operation as each other hybrid PFD carried on board. A deckhand was found using an unapproved work vest.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2022
Resolved 21 September 2022
Resolution: Crewmember provided with proper workvest.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 August 2022
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Vessel has made temporary repairs to exhaust cooling water piping in both port and starboard engine rooms with pressed fittings. Original design was welded piping. Submit plans for appropriate repair to return to original.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2022
Resolved 30 September 2022
Resolution: MI satisfied with repair as vessel rep provided list of crew who had viega fitting training.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 31 August 2022
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Vessel has installed vent openings on exterior bulkhead, above passenger loading doors, on main deck, and aft battery space bulkhead, without approval from [name withheld] plans to OCMI for approval.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2022
Resolved 28 December 2022
Resolution: Attended vessel to test closing devices. All sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 31 August 2022
Resolved
A structure is considered open to the weather when an exterior end bulkhead of the structure is open and is not fitted with any means of closing. All tonnage openings interior are blocked by permanently fitted interior furnishings and is not considered in the clear in accordance with 46 CFR 117(d)(2)(i). Tonnage openings are not fitted with j-hook devices to make openable from one side. Additionally, there is equipment stored in way of tonnage opening on second deck/aft end of house. Make corrections to tonnage openings to the satisfaction of attending MI by next credit drydock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 5 December 2022
Resolution: Resolved during drydock.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 31 August 2022
Resolved
Each survival craft must be: Secured to the vessel by a painter. One IBA was found with a slipped bowline. Operator was able to tie and secure all IBAs while inspectors were still onboard.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 31 August 2022
08 - Alarms › N/A - No Subsystem › General alarm
Issued 31 August 2022
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of electrical equipment and systems, including the following: Operational test of all emergency electrical systems. During inspection, general alarm was not audible. Rectified prior to end of inspection.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 31 August 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 March 2020
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel experienced a loss of propulsion on port engine due to a ruptured raw water cooling line. Vessel operator must produce documentation showing completion of repairs.
46 CFR 119.200
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 March 2020
Resolution: New raw water pump installed.