RTA 1 is a 2018 passenger vessel (inspected). The Coast Guard has recorded 19 inspections since 2017, most recently in November 2025, along with 22 deficiencies.

Records from 2017 to 2025. Most recent: inspection, 19 November 2025.

Built
2018
Last inspected
19 November 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 19 November 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2017–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDK3088
1496135
Flag
UNITED STATES
Maury page id
psix-1496135

Documentation record

Registered dimensions (L × B × D)104.7 ft × 25.2 ft × 8.9 ft
Registered tonnagegross 95 / net 65
ITC dimensions (L × B × D)104.7 ft × 25.2 ft × 8.9 ft
ITC tonnagegross 166 / net 49
BuilderGRAVOIS BOATS LLC · FRANKLIN, LA, UNITED STATES · built 2018
Hull materialAluminum
PropulsionDiesel
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 25 September 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it65 - Regulatory (Subpart C or D), Net Ton
166 - Convention (Subpart B), Gross Ton
95 - Regulatory (Subpart C or D), Gross Ton
49 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 19

19 November 2025 Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8271146
6 August 2025 Examination of Repairs · Administrative Inspection · Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8203994
13 January 2025 Annual Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8062990
2 December 2024 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8042109
3 August 2024 Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7973276
23 May 2024 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7917701
14 February 2024 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7865284
9 November 2023 Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7822782
2 November 2023 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7872279
10 March 2023 Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7604272
22 February 2023 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7842554
9 March 2022 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7408452
3 March 2022 Examination of Repairs · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7358582
19 May 2021 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7201392
10 February 2021 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7139018
14 December 2020 COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7110392
1 October 2020 Damage Survey · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7076468
22 July 2019 In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6758380
19 September 2017 Deadweight Survey · Administrative Inspection · Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6331669

Deficiency record · 22

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 March 2025 Resolved
A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. MI observed strainer missing from PORT and STBD engine room bilge suction. 46 CFR 182.510(b) 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 March 2025
Resolved 19 March 2025
Resolution: Received photos(uploaded) of acceptable bilge suction strainers.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 March 2025 Resolved
Each generator must have a nameplate attached to it containing the information required by Article 430 of NFPA 70. MI found both port and STBD generator missing a nameplate. 46 CFR 183.320(d) 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2025
Resolved 27 March 2025
Resolution: Received photos(uploaded) of nameplate.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 May 2024 Resolved
Propulsion machinery must be suitable in type ans design for propulsion requirements of the hull in which it is installed and capable of operating at a constant marine load under such requirements without exceeding its designed limitations. Vessel reported suspected log wedged between prop and rudder. Remove log, provide diver's report, and conduct steering and propulsion check prior to operations. 46 CFR 182.200(a)
Due 23 May 2024
Resolved 23 May 2024
Resolution: observed satisfactory steering and propulsion test.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 22 February 2024 Resolved
When using DSC techniques, coast stations and ship stations must use maritime mobile service identities (MMSI) assigned by the Commission or its designees. MI discovered vessel radio had incorrect MMSI number displayed. Input correct vessel MMSI number. 47 CFR 80.103 (b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 February 2024
Resolved 29 February 2024
Resolution: Vessel DSC radio now displays correct MMSI #.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 February 2024 Resolved
Each connection to a conductor or terminal part of a conductor must be made within a enclosure. MI discovered dead-end conductor underneath operating console station. Repair or remove to the satisfaction of the marine inspector. 46 CFR 183.340 (g)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2024
Resolved 29 February 2024
Resolution: Wiring correctly installed into junction box.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 22 February 2024 Resolved
Spanner wrenches must be provided where a 1.5 inch diameter firehose is required by 181.230(b). Aft firehose station had no spanner wrench. Provide spanner wrench. 46 CFR 181.310 (d)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 February 2024
Resolved 29 February 2024
Resolution: Spanner wrench installed on aft hose reel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 February 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards., including fire, caused by or originating in electrical equipment, and electrical shock. MI discovered two exhaust fans underneath operating console station inoperable. Repair or replace in kind. 46 CFR 183.200 (b)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 February 2024
Resolved 29 February 2024
Resolution: Both exhaust fans operational.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 22 February 2024 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. MI found the first aid kit expired. Vessel removed expired first aid kit and replaced with in kind. 46 CFR 184.710
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 22 February 2024
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 22 February 2024 Resolved
Each hatch cover must, (2) Be attached to the hatch frame or coaming by hinges, captive chains, or other devices to prevent its loss. MI found all scuttles without means of retention. Provide captive measures to prevent the loss of the scuttles. 46 CFR 174.220(b)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 March 2024
Resolved 1 March 2024
Resolution: Capative chains installed on all scuttles.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 22 February 2024 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: Inspection of all railings and bulwarks and their attachment to the hull structure. MI discovered a crack in the railing on the most FWD top railing on the Port side of the vessel. Submit repair proposal, and complete repairs to the satisfaction of the marine inspector. 46 CFR 176.802(a)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2024
Resolved 29 February 2024
Resolution: Railing found to not have crack.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 22 February 2024 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: (2) Inspection and operation of all watertight closures in the hull, decks. MI found possible hull cracks in the AFT Port scuttle. Conduct nondestructive testing to verify the hull is not cracked, if found cracked, provide repair proposal, and conduct repairs to the satisfaction of the marine inspector. 46 CFR 176.802(a)(2)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2024
Resolved 29 February 2024
Resolution: Scuttle verified to not have crack.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 22 February 2024 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Placard was missing for one of the styles of life jackets found on board. Corrected on the spot with installation of new placard. 46 CFR 185.516(a)
Action required: 10 - Deficiency Rectified
Resolved 22 February 2024
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 22 February 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. One of the fire strobes in the STBD engine room was inoperable during fire detection test. Repair or remove if strobe is deemed redundant to the system. 46 CFR 183.200 (a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 March 2024
Resolved 29 February 2024
Resolution: Strobe attached to FDS, tested and operational. Strobe now properly labeled.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 22 February 2024 Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J–1942. Hoses located on fire pumps were kinked and need to be replaced. 46 CFR 182.730 (e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 March 2024
Resolved 5 March 2024
Resolution: Recieved photographs attesting to installation of new hoses.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 22 February 2024 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. Surface corrosion was noted in lazarette due to vapors from marine sanitation device. Clean excessive corrosion in space, apply coating to prevent recurrence,and ensure marine sanitation device is properly sealed. 46 CFR 177.100
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 March 2024
Resolved 4 March 2024
Resolution: Recieved photographs attesting to proper rust prevention.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 9 November 2023 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. MIs observed quarter-sized hole in STBD bow void space. Submit repair plan, company statement attesting to cause of damage, and action plan to avoid future reoccurring damage to the satisfaction of the attending MI. 46 CFR 177.100
Condition: Design Flaw
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 November 2023
Resolution: Attended vsl and witnessed satisfactory NDT Dye Pen of 6" wide and 18" long repair that is considered a temporary repair until an approved repair plan and repair is made
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 9 March 2022 Resolved
46 CFR 182.420: Except as otherwise provided in paragraphs (b), (c), (d), and (e) of this section, all engines must be water cooled and meet the requirements of this paragraph. Vessel reported a loss of power due to STBD generator overheat causing a safety shut-down. Complete troubleshooting and repairs to the satisfaction of the USCG prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 March 2022
Resolution: Technician found dirty air filter to be the cause of the generator shut-down due to air restriction. Replaced filter, CG was present to witness operation under a load for .5 hrs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 May 2021 Resolved
This part contains requirements for the design, construction, installation, and operation of propulsion and auxiliary machinery, piping and pressure systems, steering apparatus, and associated safety systems. Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. On 19MAY2021, vessel reported a loss in starboard main engine and a loss of the starboard generator. Provide proof of satisfactory operation of the starboard main engine and generator.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2021
Resolution: 21May2021: Vessel changed fuel tank gaskets on both fuel tanks, there was degredation noted on the port gasket as well. Vsl ran started both main engines at 0629 to 0845 with no issues. [name withheld] and [name withheld] visited vessel and witnessed proper opeation
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 February 2021 Resolved
Each vessel that relies on electricity to power the following loads must be arranged so that the loads can be energized from two sources of electricity, one of these loads is the STBD generator. Following a Marine Casualty, Inspectors attended vessel to conduct pier-side testing of all electrical loads and vital systems. Inspectors discovered the following: The STBD generator display indicated the following warning message "Emergency Power System Supplying Load", the Amperage meter for the STBD generator was reading approximately 30 amps higher than the PORT generator, and Inspectors noticed an electrical associated smell when the amperage reading was high. Provide a root cause analysis for the operational condition of both the PORT & STBD generators, switchboard, conduct any necessary repairs, and conduct proper testing to satisfaction of CG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 February 2021
Resolution: Received satisfactory root cause analysis and tech reports.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 February 2021 Resolved
A vessel must be provided with a main steering gear that is of adequate strength and capable of steering the vessel at all service speeds; additionally a power driven main steering shall be provided with an arrangement that automatically resumes operation, without reset, when power is restored after a power failure. The RTA 1 lost power on the port generator and subsequently lost steering, the starboard generator was energized for approximately 20 seconds prior to losing power, resulting in a loss of steering. Prior to movement, vessel must provide technician's report, root cause analysis, and testing procedures to the satisfaction of the USCG Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 February 2021
Resolution: Witnessed satisfactory operational test of the steering gear. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 February 2021 Resolved
A vessel must be provided with a main steering gear that is of adequate strength and capable of steering the vessel at all service speeds; additionally a power driven main steering shall be provided with an arrangement that automatically resumes operation, without reset, when power is restored after a power failure. The RTA 1 lost power on the port generator and subsequently lost steering, the starboard generator was energized for approximately 20 seconds prior to also losing power, resulting in an additional loss of steering. Within 30 days provide a root cause analysis attesting to the loss of power and subsequent loss of steering to the satisfaction of the USCG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 February 2021
Resolution: Received satisfactory root cause analysis.
Operations/Management › Drills/Instruction › Not Conducted
Issued 19 September 2017 Resolved
Vessel is required to complete new to zone inspection once arriving in New Orleans, LA.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2018
Resolved 14 December 2020
Resolution: Conducted COI inspection at Sector New Orleans.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.