KONA is a 2018 passenger vessel (inspected). The Coast Guard has recorded 18 inspections since 2018, most recently in March 2026, along with 7 deficiencies and 2 casualty investigations between 2019 and 2022.

Records from 2018 to 2026. Most recent: inspection, 2 March 2026.

Built
2018
Last inspected
2 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 2 March 2026
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2018–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDK5987
1497129
Flag
UNITED STATES
Maury page id
psix-1497129

Documentation record

Registered dimensions (L × B × D)40.0 ft × 16.0 ft × 5.5 ft
Registered tonnagegross 14 / net 14
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderARMSTRONG MARINE USA INC · PORT ANGELES, WA, UNITED STATES · built 2018
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portKAILUA-KONA, HI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 August 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Simplified, Gross Ton
14 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

18 inspections, each with its date, unit and type; 7 deficiencies with the resolution recorded against each; 2 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 18

2 March 2026 Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8318962
19 March 2025 Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8096537
19 September 2024 Drydock Exam · Internal Structural Exam
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 7997413
17 January 2024 DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7846707
25 June 2023 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7722549
24 April 2023 Internal Structural Exam · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7674995
25 October 2022 Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7583796
13 June 2022 Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 7478864
19 May 2022 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7517396
8 March 2022 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7408061
20 April 2021 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7180267
25 March 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7162837
18 January 2021 Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 7127937
30 September 2020 Drydock Exam · Internal Structural Exam · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7074727
18 April 2020 Annual Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7105337
16 February 2019 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6633021
29 January 2019 DAPI Audit · Internal Structural Exam · COI Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6614826
20 April 2018 Administrative Inspection · Internal Structural Exam · Inclining Experiment · Drydock Exam · Construction Oversight
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6511834

Deficiency record · 7

01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 January 2024 Resolved
The vessel must have onboard a valid certificate which is issued by the FCC to prove installation of the radio transmitting equipment. MI found telephony safety certificate invalid and expired. Provide new certificate.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2024
Resolved 7 February 2024
Resolution: Vessel master provided current certificate with an expiration date of 1/26/2029.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 24 April 2023 Resolved
A vessel must comply with the structural design requirements of one of the standards listed. The forward starboard void compartment, bays 1-4, have pitting on bottom plate and is 25% wasted. Vessel rep must crop and renew to good metal at next drydock. MI must oversee repair and testing of new installation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 September 2024
Resolved 25 September 2024
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 25 October 2022 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances. The vessel did not conduct a dry dock inspection before the vessel's anniversary date of 30 September 2022. The vessel is restricted from carrying passengers in commercial service until a credit drydock is completed.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 25 November 2022
Resolved 25 October 2022
Resolution: Vessel conducted a credit drydock on this date.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 March 2022 Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility may be required to perform the required inspections, maintenance procedures, and hydrostatic pressure tests. The vessel’s two fixed-gas fire extinguishers have not been serviced. Conduct servicing and show proof of operations to the satisfaction of the Coast Guard prior to operating the vessel.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 April 2022
Resolved 16 March 2022
Resolution: Pre-engineered extinguisher serviced and tested sat.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 25 March 2021 Resolved
Exhaust blower switches must be located outside of any space required to be ventilated by this section, and must be of the type interlocked with the starting switch and the ignition switch so that the blowers are started before the engine starter motor circuit or the engine ignition is energized. A red warning sign at the switch must state that the blowers must be operated prior to starting the engines for the time sufficient to insure at least one complete change of air in the space served. Vessel does not have the starter or ignition switch interlocked with the mechanical ventilation required for internal gasoline tank. 46 CFR 182.460(e)
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2021
Resolved 20 April 2021
Resolution: MI verified mechanical ventilation interlocked with required system.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 25 March 2021 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each unmanned space required by this subpart. 2) All six (6) bilge lights on helm were not operational. 46 CFR 182.530(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2021
Resolved 20 April 2021
Resolution: MI verified operational bilge lights at helm.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 March 2021 Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers. STBD FWD Bilge not working in auto setting. 46 CFR 182.520(e)
Action required: 10 - Deficiency Rectified
Resolved 25 March 2021
Resolution: Corrected on spot.

Casualty record · 2

16 February 2019Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6633021
19 May 2022Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7517396
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.