Records from 1986 to 2020. Most recent: inspection, 20 October 2020.
Inspection history · 57
20 October 2020
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7080736
8 October 2019
Uninspected Passenger Vessel
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6830755
1 September 2019
Type not recorded
No type recorded · Station Pensacola · USCG Heartland District (CGD-H) · Activity 6801676
24 July 2019
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6761777
20 May 2019
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6689852
9 March 2017
Administrative Inspection · Examination of Repairs · Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6101625
29 July 2016
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5957010
23 May 2016
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5884705
25 August 2015
Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5774039
20 July 2015
Type not recorded
No type recorded · Station Pensacola · USCG Heartland District (CGD-H) · Activity 5191964
9 June 2014
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4884376
30 May 2014
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4865809
15 July 2012
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4405146
23 August 2011
Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4124557
28 July 2011
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4093972
19 November 2010
Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3893385
23 December 2008
Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3384033
16 July 2008
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3262855
26 June 2008
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3239526
30 April 2007
COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2889305
21 July 2006
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2720479
10 July 2006
In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2707921
19 June 2006
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2684584
12 October 2005
Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2513101
23 May 2005
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2363530
9 November 2004
Examination of Repairs · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2237595
13 October 2004
Damage Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2220351
18 March 2004
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2037957
8 March 2004
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2020619
6 October 2003
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1925404
27 March 2003
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1758905
25 March 2002
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1491192
4 December 2001
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1467811
4 October 2001
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1074741
15 August 2001
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1069047
1 December 1999
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1415278
8 November 1999
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 812381
4 November 1999
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1464243
17 November 1998
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1433419
8 January 1998
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 784803
2 December 1997
Re-Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1453440
19 February 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1110184
25 November 1996
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1182102
1 November 1996
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1446409
19 December 1995
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1186674
27 November 1995
Hull Examination · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1358961
14 June 1995
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1187119
21 November 1994
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 833964
14 November 1994
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1446143
23 November 1993
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 847814
16 November 1993
COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1143782
20 November 1992
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1137748
21 November 1991
Re-Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1252720
6 August 1991
Drydock Extension
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 938966
29 November 1990
Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1236638
31 January 1990
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 934842
27 August 1986
Uninspected Other
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1027898
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 October 2019
Resolved
The ring buoy grablines were rotted and easily broke when pulled on. Need to replace ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 October 2019
Resolved 8 October 2019
Resolution: Accompanied owner to West Marine where he purchased brand new ring buoy for vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 October 2019
Resolved
Vessel life jackets are required to have personal floatation device lights attached.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 8 October 2019
Resolved 8 October 2019
Resolution: Owner purchased life jacket lights at West Marine.
Sail Rigging › Chainplates › Materials
Issued 4 May 2017
No resolution recorded
During a survey on 25AUG15 the chainplates were not inspected. Owner has decided to replace all eight to accommodate future inspections. Owner was advised that no passengers may be carried till the newly installed chainplates can be tested and inspected satisfactorly.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 May 2017 — due date passed with no resolution recorded
Sail Rigging › Running Rigging › Topping Lifts/Attachments
Issued 25 August 2015
Resolved
Items 1, 2, 3, 5, and 6 of the rigging survey received Dec 14, 2015 are to be completed by the vessel's next drydock exam.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 February 2017
Resolved 4 May 2017
Resolution: New 835 issued due to changes of this one. Act
Sail Rigging › Running Rigging › Topping Lifts/Attachments
Issued 25 August 2015
Resolved
Items 4, 7, 8, 9, and 10 of the rigging survey received Dec 14, 2015 are to be completed by February 1, 2016.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 February 2016
Resolved 23 May 2016
Resolution: Vessel owner has completed items 04 and 07 thru 10 noted on rigging survey dated 14Dec15.
Sail Rigging › Sails › Stitching
Issued 25 August 2015
Resolved
Items 11 and 12 of the rigging survey received Dec 14, 2015 are to be completed by February 1, 2016. In addition, the main sail must be replaced or properly repaired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 February 2016
Resolved 23 May 2016
Resolution: Main sail was replaced with new and items 11 and 12 were corrected from rigging survey dated 14Dec15.
Engineering › Fuel Oil Service System › Hose
Issued 27 May 2014
Resolved
Provide approved fuel supply hose to main engine (remove splice) IAW 46 CFR 182.720
Action required: 705 - Other - as specified
Due 30 June 2014
Resolved 9 June 2014
Resolution: Hose was replaced with correct hose, def cleared.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 27 May 2014
Resolved
Provide current and corrected charts for vessel operating area IAW 46 CFR 184.420
Action required: 705 - Other - as specified
Due 30 June 2014
Resolved 9 June 2014
Resolution: O/O provided current and corrected charts. Def cleared.
Lifesaving › Hand Flares › Expired
Issued 27 May 2014
Resolved
Provide new distress signals - 3 orange smoke and 3 red night IAW 46 CFR180.68 (b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 May 2014
Resolution: Provided required distress signals prior to completion of exam. Def Cleared.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 May 2014
Resolved
Replace expired medicine in first aid kit and provide ammonia inhalants IAW 46 CFR 160.041
Action required: 705 - Other - as specified
Due 30 June 2014
Resolved 9 June 2014
Resolution: expired meds were replaced, def cleared.
Lifesaving › Lifebuoys › Serviceable
Issued 27 May 2014
Resolved
Repair or replace lifering buoy due to large gash IAW 46 CFR 180.70
Action required: 705 - Other - as specified
Due 30 June 2014
Resolved 9 June 2014
Resolution: Life ring buoy was replaced, def cleared.
Engineering › Fuel Oil Service System › Hose
Issued 28 July 2011
Resolved
Fuel return hose was found not double clamped, provide clamp accordingly.
Condition: Improper Installation
Due 12 August 2011
Resolved 23 August 2011
Resolution: Evidence to substantiate correction received and made part of vessel''s electronic folder.
Lifesaving › Visual Distress Signals (General) › Expired
Issued 28 July 2011
Resolved
Required orange smoke signals were found expired, replace accordingly.
Condition: Improper/Lack of Maintenance
Due 12 August 2011
Resolved 23 August 2011
Resolution: Evidence to substantiate correction received and made part of vessel''s electronic folder.
Navigation › Collision/Grounding Avoidance › Day Shapes
Issued 28 July 2011
Resolved
Vessel could not provide adequate day-shape for Auxiliary Sail service, provide accordingly.
Condition: Design Flaw
Due 12 August 2011
Resolved 23 August 2011
Resolution: Evidence to substantiate correction received and made part of vessel''s electronic folder.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 28 July 2011
Resolved
Lifeline was found not to be bouyant, replace accordingly.
Condition: Improper Installation
Due 12 August 2011
Resolved 23 August 2011
Resolution: Evidence to substantiate correction received and made part of vessel''s electronic folder.
Engineering › Fuel Oil Service System › Filter
Issued 26 June 2008
Resolved
Replace plastic plug on fuel filter with metallic plug as per 46 CFR 182.455
Action required: 705 - Other - as specified
Due 26 July 2008
Resolved 16 July 2008
Resolution: Plug replaced.
Engineering › Fuel Oil Service System › Valve
Issued 26 June 2008
Resolved
Relocate fuel shutoff valve to fuel tank as per 46 CFR 182.15-40 (b) (3)
Action required: 705 - Other - as specified
Due 26 July 2008
Resolved 16 July 2008
Resolution: Fuel valve relocated.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 26 June 2008
Resolved
Secure loose fiberglass isulation as per 46 CFR 176.800
Action required: 705 - Other - as specified
Due 26 July 2008
Resolved 16 July 2008
Resolution: Fiberglass secured.
Documentation › Certificates/Documents › FCC SSL
Issued 19 June 2006
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 July 2006
Resolved 18 July 2006
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 19 June 2006
Resolved
Properly mark stowage area for lifejackets and separate child and adult lifejackets as required by 46 CFR 180.78
Action required: 705 - Other - as specified
Due 19 July 2006
Resolved 18 July 2006
Resolution: Properly marked stowage are for lifejackets and moved child lifejackets to separate stowage area.
Documentation › Logs/Records › Logbook (official)
Issued 19 June 2006
Resolved
Provide current training logbook, lifesaving equipment maintenance log and bridge log as required by 46 CFR 185.420 and 485.702
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 July 2006
Resolved 18 July 2006
Resolution: Provided current training logbook and bridge log. Removed the requirement for lifesaving maintenance log, because the vessel is not required to maintain this log.
Navigation › Piloting/Steering › Marine Charts
Issued 19 June 2006
Resolved
Provide current charts as required by 46 CFR 184.420
Action required: 705 - Other - as specified
Due 19 July 2006
Resolved 18 July 2006
Resolution: Provide current charts
Construction/Loadline › Structures
Issued 19 November 2001
Resolved
Crop and renew to good wood main deck above forepeak where delaminated and repair FRP sheath as original 3/8" glass using 1 1/2 oz matt and 24 oz woven as per original lay up schedule and in accordance with NVIC 8-87. LEGACY COMPONENT DESC: Deck Plating
Due 1 December 2001
Resolved 1 December 2001
Resolution: Renew wood and fiberglass as original.
Construction/Loadline › Structures
Issued 19 November 2001
Resolved
Crop and renew to good wood at main deck above lazerette. Repair FRP sheath as original 3/8" glass using 1 1/2 oz matt and 24 oz woven as per original lay up schedule and in accordance with NVIC 8-87. LEGACY COMPONENT DESC: Deck Plating
Due 1 December 2001
Resolved 1 December 2001
Resolution: Croped out affected area and renewed as original.
Construction/Loadline › Hull
Issued 19 November 2001
Resolved
Repair all blistered areas on hull to the satisfaction of the attending U.S. Coast Guard Marine Inspector and in accordance with NVIC 8-87. LEGACY COMPONENT DESC: Fiberglass
Due 1 December 2001
Resolved 1 December 2001
Resolution: Blistering was ground out and repairs made using west epoxy system.
Construction/Loadline › Hull
Issued 19 November 2001
Resolved
Provide Fasteners for cabin portlights in forward accommodation space LEGACY COMPONENT DESC: portlights
Due 1 December 2001
Resolved 1 December 2001
Resolution: Provided suitable fasteners for all portlights.
Construction/Loadline
Issued 15 August 2001
Resolved
PROVIDE DEAD LIGHT COVERS ON PORT LIGHTS BELOW MAINDECK AS REQUIRED BY 46CFR 171.117.
Condition: Unknown
Due 15 August 2001
Resolved 15 August 2001
Lifesaving
Issued 15 August 2001
Resolved
PROVIDE IMPROVED HAND RAILS AROUND MAIN DECK AS REQUIRED BY 46CFR 177.900.
Condition: Unknown
Due 15 August 2001
Resolved 15 August 2001
Engineering
Issued 15 August 2001
Resolved
PROVIDE PROPER FUEL HOSES AS REQUIRED BY 46CFR 182.720.
Condition: Unknown
Due 15 August 2001
Resolved 15 August 2001
Documentation
Issued 15 August 2001
Resolved
PROVIDE HARD COPY OF CERTIFICATE OF DOCUMENTATION AS REQUIRED BY 46CFR 67.7
Condition: Unknown
Due 15 August 2001
Resolved 15 August 2001
Documentation
Issued 15 August 2001
Resolved
PROVIDE NAVIGATION PUBLICATIONS AS REQUIRED BY 46CFR 184.420
Condition: Unknown
Due 15 August 2001
Resolved 15 August 2001
Engineering
Issued 4 November 1999
Resolved
REPAIR FUEL OIL LEAK ON MAIN DIESEL ENGINE SUPPLY LINE, PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 8 November 1999
Resolved 15 November 1999
Engineering
Issued 1 November 1996
Resolved
PROVIDE MEANS TO PROPERLY CLOSE THE ENGINE ROOM VENTILATION DUCTS IAW 46 CFR 182.465.
Condition: Unknown
Due 4 December 1996
Resolved 25 November 1996
Engineering
Issued 1 November 1996
Resolved
INSTALL FUEL SHUTOFF VALVES AT THE ENGINE TO THE MAIN PROPULSION ENGINE ANDTHE GENERATOR IAW 46 CFR 182.455(B)(4).
Condition: Unknown
Due 4 December 1996
Resolved 25 November 1996
Navigation
Issued 1 November 1996
Resolved
PROVIDE ONBOARD VESSEL FOR REVIEW, UP TO DATE NAVIGATIONAL CHARTS IAW 46 CFR 184.420.
Condition: Unknown
Due 4 December 1996
Resolved 25 November 1996
Lifesaving
Issued 1 November 1996
Resolved
INSTALL RETRO-REFLECTIVE MATERIAL TO VESSEL'S RING BUOY AND RENEW RING BUOY'S LIFELINE IAW 46 CFR 180.70 & 185.604(I).
Condition: Unknown
Due 4 December 1996
Resolved 25 November 1996
Lifesaving
Issued 1 November 1996
Resolved
PROVIDE ONBAORD VESSEL, TWO LIFEJACKET DONNING PLACARDS, ONE PLACARD FOR EACH STYLE OF LIFEJACKETS CARRIED ONBOARD VESSEL IAW 46 CFR 185.516.
Condition: Unknown
Due 4 December 1996
Resolved 25 November 1996
Fire Fighting
Issued 1 November 1996
Resolved
MARK ALL EXTERIOR SIDES OF EMERGENCY EXITS WITH THE WORDS "EMERGENCY EXIT KEEP CLEAR" IAW 46 CFR 185.606.
Condition: Unknown
Due 4 December 1996
Resolved 25 November 1996
Fire Fighting
Issued 1 November 1996
Resolved
PROVIDE ONBOARD VESSEL A FIRE FIGHTING DRILLS AND TRAINING LOG IAW 46 CFR 185.524 & 185.420.
Condition: Unknown
Due 4 December 1996
Resolved 25 November 1996
Documentation
Issued 1 November 1996
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 4 December 1996
Resolved 25 November 1996
Construction/Loadline
Issued 27 November 1995
Resolved
STEP MASK PRIOR TO 30 DEC 95 TO ALLOW FOR COAST GUARD MARINE INSPECTOR'S INSPECTION.
Condition: Unknown
Due 27 November 1995
Resolved 27 November 1995
Lifesaving
Issued 27 November 1995
Resolved
PROPERLY SECURE EMERGENCY EXIT PLACARD IAW 46 CFR 185.30-15(A) AND PROVIDE LANYARD FOR HATCH COVER.
Condition: Unknown
Due 27 November 1995
Resolved 27 November 1995
Electrical
Issued 27 November 1995
Resolved
PROPERLY WIRE A/C UNIT AND A/C COOLING WATER PUMP TO BREAKER PANEL AS REQUIRED IN 46 CFR 183.10-20.
Condition: Unknown
Due 27 November 1995
Resolved 27 November 1995
Electrical
Issued 27 November 1995
Resolved
PROVIDE BATTERY COVER FOR GENERATOR THAT MEETS THE REQUIREMENTS OF 46 CFR 183.05-20(A).
Condition: Unknown
Due 27 November 1995
Resolved 27 November 1995
Navigation
Issued 27 November 1995
Resolved
REPAIR PORT RUNNING LIGHT WIRES.
Condition: Unknown
Due 27 November 1995
Resolved 27 November 1995
Engineering
Issued 27 November 1995
Resolved
TIGHTEN/REPACK SHAFT PACKING TO REDUCE LEAKAGE FOR PROPULSION SHAFT.
Condition: Unknown
Due 27 November 1995
Resolved 27 November 1995
Lifesaving
Issued 27 November 1995
Resolved
PROPERLY ATTACH 60 FOOT LINE TO RING BOUY.
Condition: Unknown
Due 27 November 1995
Resolved 27 November 1995
Navigation
Issued 14 November 1994
Resolved
PROVE PROPER OPERATION OF EMERGENCY TILLER SYSTEM.
Condition: Unknown
Due 14 December 1994
Resolved 7 December 1994
Electrical
Issued 14 November 1994
Resolved
INSTALL 110V OUTLET COVER IN AFT CABIN.
Condition: Unknown
Due 14 December 1994
Resolved 7 December 1994
Documentation
Issued 14 November 1994
Resolved
PROVE ENROLLMENT INTO A RANDOM DRUG TESTING PROGRAM IAW 46 CFR 16
Condition: Unknown
Due 26 November 1994
Resolved 7 December 1994
Lifesaving
Issued 14 November 1994
Resolved
PROVIDE ONE ADULT TYPE I PFD
Condition: Unknown
Due 26 November 1994
Resolved 7 December 1994
Electrical
Issued 14 November 1994
Resolved
INSTALL VOLTAGE AND AMP GAUGE ON 110 VOLT GENERATOR SYSTEM IAW 46 CFR 183.10-5(g).
Condition: Unknown
Due 14 December 1994
Resolved 7 December 1994
Documentation
Issued 14 November 1994
Resolved
PROVIDE DRAWING FOR COAST GUARD EXAMINATION AND APPROVAL INSTALLATION OF SECOND MAST.
Condition: Unknown
Due 26 November 1994
Resolved 7 December 1994
Engineering
Issued 14 November 1994
Resolved
REPAIR BROKEN EXHAUST FLANGE BOLT (INBOARD LOWER)
Condition: Unknown
Due 14 December 1994
Resolved 7 December 1994
Construction/Loadline
Issued 16 November 1993
Resolved
PROVIDE FIXED PIPING FOR FORWARD BILGE PUMP IN ACCORDANCE WITH 46CFR 182.40-5(B).
Condition: Unknown
Due 16 November 1993
Resolved 16 November 1993