MAURY USCG vessel records
← All vessels

SAGAMORE

SAGAMORE is a freight ship. The Coast Guard has recorded 66 inspections since 2018, most recently in August 2026, along with 39 deficiencies and 1 casualty investigation in 2024.

Records from 2018 to 2026. Most recent: inspection, 5 August 2026.

Built
Not recorded
Last inspected
5 August 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9322009
1497509
Flag
UNITED STATES
Maury page id
psix-1497509

Inspections, by type

…with no type recorded1
Years with a record 9 calendar years (2018–2026)
The 66 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Documentation record

Registered dimensions (L × B × D)565.4 ft × 83.0 ft × 44.3 ft
Registered tonnagegross 16,803 / net 8,648
ITC dimensions (L × B × D)565.4 ft × 83.0 ft × 44.3 ft
ITC tonnagegross 16,803 / net 8,648
BuilderSTOCZNLA SZCZECINSKA NOWA SP. Z O.O. · SZCZECIN, POLAND
Hull materialSteel
PropulsionDiesel Direct
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portDOVER, DE
Trade endorsementsRegistry
DocumentationValid · issued 3 February 2026 · expires 28 February 2027
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it8648 - Convention (Subpart B), Net Ton
22749 - Dead Weight, Metric Ton
16803 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 66

5 August 2026 Explosive Handling Operation-Military
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8455956
1 June 2026 Explosive Handling Operation-Commercial
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8382011
28 May 2026 Explosive Handling Operation-Commercial
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8377789
2 March 2026 Explosive Handling Operation-Military
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8316634
5 January 2026 Annual Inspection
Physical examination · Activities Europe · Activity 8290648
21 December 2025 Explosive Handling Operation-Commercial
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8284088
15 October 2025 COI Inspection · MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 8246506
16 May 2025 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 8137314
12 April 2025 Administrative Inspection
Administrative · Activities Europe · Activity 8110463
14 March 2025 Administrative Inspection · Deficiency Check
Physical examination · Activities Europe · Activity 8093678
16 February 2025 Administrative Inspection
Administrative · Activities Europe · Activity 8080186
27 January 2025 Explosive Handling Operation-Commercial
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8066776
27 January 2025 Explosive Handling Operation-Military
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8070644
18 December 2024 Administrative Inspection
Administrative · Activities Europe · Activity 8049127
27 November 2024 Explosive Handling Operation-Commercial
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8038054
15 October 2024 Explosive Handling Operation-Commercial
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8013840
15 October 2024 Explosive Handling Operation-Commercial
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8013846
17 September 2024 Administrative Inspection
Administrative · Activities Europe · Activity 8003830
5 September 2024 MSP Select Handover Survey · MSP Periodic Oversight
Type not classified · Sector North Carolina · USCG East District (CGD-E) · Activity 7990081
3 September 2024 Explosive Handling Operation-Military
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7990993
3 September 2024 Explosive Handling Operation-Military
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7991002
16 August 2024 Administrative Inspection
Administrative · Activities Europe · Activity 7982494
15 August 2024 Type not recorded
No type recorded · Activities Europe · Activity 7986586
15 July 2024 Explosive Handling Operation-Commercial
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7956683
15 July 2024 Administrative Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7958863
30 May 2024 Administrative Inspection
Administrative · Activities Europe · Activity 7922933
27 March 2024 Administrative Inspection
Administrative · Activities Europe · Activity 7885622
26 March 2024 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7885423
13 February 2024 Explosive Handling Operation-Commercial
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7869166
28 December 2023 ISM Oversight · Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7844205
26 December 2023 Explosive Handling Operation-Commercial
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7839708
26 December 2023 Explosive Handling Operation-Commercial
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7839710
14 December 2023 Administrative Inspection
Administrative · Activities Europe · Activity 7838883
20 November 2023 Administrative Inspection
Administrative · Activities Europe · Activity 7827265
11 September 2023 Administrative Inspection
Administrative · USCG East District (dp) · USCG East District (CGD-E) · Activity 7789724
11 September 2023 Administrative Inspection
Administrative · Activities Europe · Activity 7789956
4 August 2023 Explosive Handling Operation-Military
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7765811
14 July 2023 Deficiency Check · MSP COI Oversight · MTSA/ISPS Verification · Administrative Inspection · MSP Select Handover Survey
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7720801
10 July 2023 Explosive Handling Operation-Military
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7738273
5 June 2023 Explosive Handling Operation-Commercial
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7704802
11 May 2023 Administrative Inspection
Administrative · Activities Europe · Activity 7686950
3 May 2023 Internal Structural Exam · Drydock Exam
Physical examination · Activities Europe · Activity 7673742
7 March 2023 Explosive Handling Operation-Military
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7646857
30 January 2023 Explosive Handling Operation-Commercial
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7626391
2 November 2022 MSP Annual Oversight · Annual Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7587893
11 August 2022 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7530634
1 August 2022 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7522128
4 February 2022 Explosive Handling Operation-Military
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7390902
10 January 2022 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 7378011
10 November 2021 Explosive Handling Operation-Military
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7347153
8 November 2021 MSP Annual Oversight · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7347462
25 October 2021 Explosive Handling Operation-Military
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7331658
27 June 2021 Explosive Handling Operation-Military
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7225908
20 May 2021 Administrative Inspection · Underwater Inspection in lieu of Drydock
Physical examination · Activities Europe · Activity 7207111
1 March 2021 Explosive Handling Operation-Military
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7145737
26 October 2020 Deficiency Check · Annual Inspection · In-Service Inspection · Administrative Inspection · MSP Annual Oversight
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7084648
30 October 2019 Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6845175
30 September 2019 Deficiency Check · MSP Annual Oversight · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6824504
28 September 2019 Explosive Handling Operation-Military
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6820467
7 August 2019 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6775313
24 June 2019 Explosive Handling Operation-Military
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6718747
23 February 2019 Explosive Handling Operation-Military
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6630366
21 December 2018 Administrative Inspection
Administrative · Activities Europe · Activity 6601315
10 December 2018 Explosive Handling Operation-Military
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6595323
29 August 2018 Deficiency Check · Administrative Inspection · Examination of Repairs
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6552395
9 June 2018 MARPOL Annex I Examination · Reflagging & Initial Certification · MARPOL Annex IV Survey · MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 6438617

Deficiency record · 39

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 October 2025 Resolved
For ships constructed on or after 1 July 2014, a minimum of two two-way portable radiotelephone apparatus for each fire party for fire-fighter's communication shall be carried on board. Those two-way portable radiotelephone apparatus shall be of an explosion-proof type or intrinsically safe. Ships constructed before 1 July 2014 shall comply with the requirements of this paragraph not later than the first survey after 1 July 2018. The fire-fighting team did not have explosion proof or intrinsically safe radios. Cite: SOLAS (2020) II-2/Reg 10.4
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2025
Resolved 30 October 2025
Resolution: DNV submitted documentation certifying intriscally safe radios have been verfied onboard of vessel. Deficiency cleared.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for rating for watchkeeping
Issued 15 October 2025 Resolved
When the service of able seaman-limited or able seamen-special is authorized for only a part of the required number of able seamen on board a vessel, the combined percentage of those individuals so qualified may not be greater than 50% of the required number. While conducting a review of vessel’s manning, the unlicensed deck crew comprised the following: two AB-unlimited, two AB-limited, and two ordinary OS with RFPNW. Only two of the required 3 AB-unlimited positions were filled. Three AB-unlimiteds are required to complement the deck department crew. Cite: 46 USC 7312(e)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2025
Resolved 19 November 2025
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 15 October 2025 Resolved
Electrical installations shall be such that electrical services essential for safety will be ensured under various emergency conditions. An emergency light at the abandon ship muster station had a discolored lens, reducing the ability to provide adequate luminosity. SOLAS (2009) II-1/ Reg 40.1.2.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 30 October 2025
Resolution: Resolved to satisfaction of USCG Inspector prior to departure.
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 15 October 2025 Resolved
An International Oil Pollution Prevention Certificate shall be issued, after an initial or renewal survey in accordance with the provisions of regulation 6 of this Annex, to any oil tanker of 150 gross tonnage and above and any other ships of 400 gross tonnage and above which are engaged in voyages to ports or offshore terminals under the jurisdiction of other Parties to the present Convention. The IOPP Form B listed the wrong tank capacity for Drain Oil Tank – No. 10. The IOPP tank capacity listed 10.80 m3 but is actually 10.50 m3. MARPOL Annex I/Reg 7.1
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 16 October 2025
Resolution: Resolved to satisfaction of USCG Inspector prior to departure. Class updated IOPP certificate to reflect correct tank volume.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 15 October 2025 Resolved
The training manual, which may comprise several volumes, shall contain instructions and information, in easily understood terms illustrated wherever possible, on the life-saving appliances provided in the ship and on the best methods of survival. Any part of such information may be provided in the form of audio-visual aids in lieu of the manual. The following shall be explained in detail donning of lifejackets, immersion suits and anti-exposure suits, as appropriate. During the abandon ship drill, identified that crew was issued two types of lifejackets. The SOLAS training manual did not provide instructions on donning the different types of lifejackets. SOLAS (2009) III/Reg 35.3.1
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 15 October 2025
Resolution: Resolved to satisfaction of USCG Inspector prior to departure.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 15 October 2025 Resolved
Before the ship leaves port, and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Port side bridge wing life buoy was found with a fractured shell and no longer serviceable for use.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 18 October 2025
Resolution: Resolved to satisfaction of USCG Inspector submitted photographic evidence of new life buoy meeting SOLAS requirements.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 15 October 2025 Resolved
Posters or signs shall be provided on or in the vicinity of survival craft and their launching controls and shall illustrate the purpose of controls and the procedures for operating the appliance and give relevant instructions or warnings, be easily seen under emergency lighting conditions; and use symbols in accordance with the recommendations of the Organization. The liferaft launching procedures were not posted under emergency lighting. Cite: SOLAS (2020) III/Reg 9.2
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 15 October 2025
Resolution: Resolved to satisfaction of USCG Inspector prior to departure.
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 14 March 2025 Resolved
Whenever a vessel is deprived of the service of a member of its complement, and the master or person in charge is unable to find appropriate credentialed personnel to man the vessel […] a report of sailing short must be filed with the OCMI having cognizance for inspection in the area in which the vessel is operating, or the OCMI within whose jurisdiction the voyage is completed. Vessel master made sailing short notification for the position of Oiler from Port Abu Qir, Egypt to Port Mersin, Turkey. Vessel has 30 days to fill position and provide documentation to our office's satisfaction. SOLAS Ch. IV Reg. 15
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 April 2025
Resolved 24 March 2025
Resolution: Reviewed crew list and mariners' MMCs. Vessel has returned to full manning.
01 - Certificates & Documentation › 011 - Ships Certificates › Minimum Safe Manning Document
Issued 20 November 2023 Resolved
Reported sailing short 1 x Oiler on 20NOV23
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 December 2023
Resolved 11 January 2024
Resolution: Sailing short status modified by activity 7844205 (Sector North Carolina)
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 17 July 2023 Resolved
TO ASSIST IN CASUALTY INVESTIGATIONS, SHIPS WHEN ENGAGED ON INTERNATIONAL VOYAGES SHALL BE FITTED WITH A VOYAGE DATA RECORDER(VDR); VESSE'S VDR PANEL IS SHOWING A FAULT.
Condition: Design Flaw
Action required: 702 - Prior to embarking on international voyage
Resolved 31 July 2023
Resolution: Notified of correction to satisfaction of RO.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 July 2023 Resolved
MAIN AND EMERGENCY SWITCHBOARDS SAHLL BE PROVIDED WITH NON-CONDUCTING MATS AT THE FRONT AND REAR OF SWITCHBOARD; VESSEL'S EMERGENCY S/B WAS MISSING MAT.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 17 July 2023
Resolved 31 July 2023
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 12 May 2023 Resolved
Except as otherwise provided in this title, only a citizen of the United States may serve as master, chief engineer, radio officer, or officer in charge of a deck watch or engineering watch on a documented vessel. Except as otherwise provided in this section, on a documented vessel — each unlicensed seaman must be— (i) a citizen of the United States; (ii) an alien lawfully admitted to the United States for permanent residence; (iii) a foreign national who is enrolled in the United States Merchant Marine Academy. Cite: 46 USC 8103(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2023
Resolution: Verrified IMO crew list. All crewmembers onboard are US Citizens.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 12 May 2023 Resolved
The company should ensure that each ship is manned with qualified, certificated and medically-fit seafarers in accordance with national and international requirements. The ship sailed between Germany and Portugal with two foreign crew members (1 AB and 1 Motorman). The USCG does not recognize foreign licenses or credentials (certificates of competency) and does not issue flag state endorsements to foreign mariners [STCW I/2 and STCW Article VI(2)]. Based on the proposed crew list received 11May2023 the ship requested to sail with foreign crew members (3 ABs and 3 motorman). SOLAS (2014) IX/Reg 3.1 ISM Code Part A 6.2.1 705: 3 months. Due 12Aug2023
Action required: 705 - Other - as specified
Due 10 August 2023
Resolved 16 October 2023
Resolution: Received acceptable internal ISM audit report.
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 4 November 2022 Resolved
United States vessels which need to replace one or more persons while on a foreign voyage and outside the jurisdiction of the United States, in order to meet manning requirements, may use non-U.S. credentialed personnel without a TWIC, except for the positions of master and radio officer, until the vessel returns to a port at which in the most expeditious manner replacements who are citizens of the United States can be obtained. Vessel currently has 06 foreign nationals serving as ABs and Oilers. Rectify prior to departure. 46 CFR 15.720(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 November 2022
Resolution: Verified replacement crew of 4 ABs and 2 Oilers. Checked all crew credentials, TWICs, and Medical Certificates, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 2 November 2022 Resolved
The following fire protection systems shall be kept in good working order so as to ensure their required performance if a fire : structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions. Found fire door on starboard side, 5th deck, was not securing properly. SOLAS 74 (2020 Con. Ed.) II-2/14.2.1.1.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 November 2022
Resolved 3 November 2022
Resolution: Demonstrated fire door latches properly.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 November 2022 Resolved
The discharge containment required by, 33 CFR 155.310, and 155.320 of this chapter, as applicable, is in place and periodically drained to provide the required capacity; each drain and scupper is closed by the mechanical means required by 155.310. Found starboard fueling containment drain plugs inoperable. 33 CFR 156.120(n) & (o)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 November 2022
Resolved 3 November 2022
Resolution: Demonstrated operable drain plugs for starboard side fueling containment.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 November 2022 Resolved
The discharge containment required by 33 CFR 155.310, and 155.320 of this chapter, as applicable, is in place and periodically drained to provide the required capacity; each drain and scupper is closed by the mechanical means required by 155.310. Found port side fueling containment missing drain plug. 33 CFR 156.120(n) & (o)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 November 2022
Resolved 3 November 2022
Resolution: Replaced missing drain plug in portside fueling containment.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 2 November 2022 Resolved
In the case of a lifeboat arranged for free-fall launching, at least once every three months during an abandon ship drill the crew shall board the lifeboat, properly secure themselves in their seats and commence launching procedures up to, but not including, the launch of the boat. The lifeboat shall then be either free-fall launched or lowered into the water...In both cases, the life boat shall there after be maneuvered in the water by the operating crew. Vessel could not provide documentation that the free-fall lifeboat had been launched and maneuvered in the water in the last three months. SOLAS 74 (2020 Con. Ed.) III/19.3.4.4
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2022
Resolved 3 November 2022
Resolution: Demonstrated proper launching and maneuvering of freefall lifeboat by lowering the lifeboat into the water with minimum operating crew.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 November 2022 Resolved
Containers, brackets, racks, and other similar stowage locations for life-saving equipment shall be marked with symbols IAW the recommendations of the Organization indicating the devices stowed in that location for that purpose. Found ring buoy on aft, port side, missing placard. SOLAS 74 (2020 Con. Ed.) III/20.10
Action required: 10 - Deficiency Rectified
Due 2 November 2022
Resolved 2 November 2022
Resolution: Replaced missing life buoy placard, corrected on the spot.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 November 2022 Resolved
All electrical equipment apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. Found disconnected grounding wire on port side anchor winch. SOLAS 74 (2004 Con. Ed.) II-1/45.1.3
Action required: 10 - Deficiency Rectified
Due 2 November 2022
Resolved 2 November 2022
Resolution: Reattached grounding wire for winch, corrected on the spot.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 November 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on-board. Emergency deck lighting on starboard side is inoperable. Attendance by Coast Guard and Class. 74 SOLAS(20) I/11(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 December 2021
Resolution: Starboard emergency deck light had been repaired and tested satisfactorily.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 10 November 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on-board. Nine fire hoses found to be in un-serviceable condition. Attendance by Coast Guard and Class. 74 SOLAS (20) I/11(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 December 2021
Resolution: Nine fire hoses were replaced with new fire hoses and pressure tested at 103 psi; all sat.
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 10 November 2021 Resolved
No vessel may be navigated unless it has in its service and on-board the crew compliment required by the COI. Vessel is short the third engineer as per the manning certificate.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 November 2021
Resolution: 3AE was onboard, verified MMC and TWIC; all sat.
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 10 November 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on-board. Sound powered phone on forecastle is inoperable. 74 SOLAS (20) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 November 2021
Resolution: Sound powered phone was repaired and tested; all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 November 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on-board. Dead end cable discovered aft of cargo hold number 4 main deck on stbd side near engine room escape hatch. 74 SOLAS (20) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 December 2021
Resolution: Crew did first verify that electical cable was not in use for any circuit and had no power. Installed shrink wrap on cut end of cable and inserted cable into metal conduit pipe. Secured cable to conduit at open end with a stainless
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 10 November 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on-board. Dog on overhead equipment loading hatch in steering gear room is missing. 74 SOLAS (20) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 December 2021
Resolved 1 December 2021
Resolution: Crew removed the pin, straightened, using heat and press. Crew then drilled and tapped the pin so that a stud could be used to secure the dog to the pin. Assembly was installed back into hatch once repairs were made. All found in order.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 10 November 2021 Resolved
No person may conduct a transfer unless each drain and scupper is closed by mechanical means. Small discharge containment plugs missing on port bunkering station. Cleared on the spot. 33 CFR 156.120(o)
Action required: 10 - Deficiency Rectified
Resolved 10 November 2021
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 10 November 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on-board. STBD FWD immersion suit and PFD locker was found in un-servicable condition. Corrected on the spot. 74 SOLAS (20) I/11(a)
Action required: 10 - Deficiency Rectified
Resolved 10 November 2021
05 - Radio Communications › N/A - No Subsystem › Performance standards for radio equipment
Issued 2 November 2020 Resolved
After any survey of the ship under regulations 7, 8, 9, or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey without the sanction of the administration. Vessel installed new RADAR and was unable to provide proof of appropriate plan review and installation oversight by USCG or DNVGL. 74 SOLAS (14) I/11(b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2020
Resolution: See Class Report #1523336.
02 - Structural Conditions › N/A - No Subsystem › Openings to cargo area, doors, ... scuttles
Issued 2 November 2020 Resolved
Machinery space openings in position 1 or 2 shall be properly framed and efficiently enclosed by steel casings of ample strength. Vessel's engine room vent trunk access plates on the main deck found missing securing bolts due to them being sheared off. Vessel to open access plate to allow for proper inspection and demonstrate proper securing. 66 ILLC Annex 1/17
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2020
Resolution: See Class Report #1523336.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 2 November 2020 Resolved
The company should ensure that each ship is appropriately manned in order to encompass all aspects of maintaining safe operations on board. Vessel found 50% of the crew required for reduced operating status in accordance with the vessel's published Safety Management System. 74 SOLAS (14Cons) IX/3.1, ISM Code Part A 6.2.2
Action required: 10 - Deficiency Rectified
Resolved 2 November 2020
Resolution: Company issued updated ROS manning requirement per vessel's SMS.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 2 November 2020 Resolved
The manning requirements for a particular vessel are determined by the OCMI after consideration of applicable laws, the regulations in this part, and all other factors involved such as: emergency situations, size and type of vessel, installed equipment... Vessel is currently in 'inactive' status but has not surrendered the COI. Owners and operators who wish to maintain their COI or international certificates, but enter into an “inactive” status with reduced manning on board, must request the manning reduction from the OCMI. The owner or operator should provide an attestation from the master that the VSP and the SMS can be adhered to with the proposed reduced manning. If this is not possible, the vessel will be required to surrender the associated certificates. 46 CFR 15.501
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 December 2020
Resolution: Verified vessel's ROS plan matches SMS requirements for minimum manning, to include master and chief engineer.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 2 November 2020 Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. Discovered weeping located at the #3 SSDG fuel pump fitting. 74 SOLAS (2004 cons) II-1/26.1
Action required: 10 - Deficiency Rectified
Resolved 2 November 2020
Resolution: Crew corrected the weeping during the inspection to the satisfaction of the CG MI team.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 2 November 2020 Resolved
Escape from machinery spaces of category A. Two sets of steel ladders, one of these shall be located within a protected enclosure from the lower part of the space with self-closing fire doors. Engine Room escape trunk door and machinery space door at common trunk entry did not have a completely closing self-latch. 74 SOLAS (2004 cons) II-2/13.4.2.1
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 December 2020
Resolution: Verified escape E/R trunk door and machinery space door latch properly.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 2 November 2020 Resolved
The means for securing and maintaining weathertightness shall [...] ensure that the tightness can be maintained in any sea conditions. Lazarette emergency escape hatch dog needs tightening to ensure proper weathertightness. 66 ILLC Annex 1/16.4
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 December 2020
Resolution: Verified lazarette emergency esccape hatch dog properly tightened.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 November 2020 Resolved
Electrical installations shall be such that the safety of crew and ship from electrical hazards will be ensured. Main deck crew head contained dead end wires that shall be properly capped or removed. 74 SOLAS (2004 cons) II-1/40.1.3
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 December 2020
Resolution: Verified the proper installation of a junction box to encapsulate wiring.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 2 November 2020 Resolved
The normal equipment of every lifeboat shall consist of a food ration [...] vacuum packed in a flexible packaging material. Several life boat food rations discovered with lost vacuum seals, as required. 74 SOLAS (14 Cons) III/31.1.1.1 & LSA Code 4.4.8.12 & 4.1.5.1.18
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 December 2020
Resolution: Verified the food rations in the lifeboat were replaced and vacuum sealed, as required.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 2 October 2019 Resolved
Vessels larger than 100GT must meet the requirements of the FCC Bridge to Bridge Act. Provide a valid bridge to bridge radio certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 October 2019
Resolution: Received, reviewed and accepted FCC Bridge to Bridge certificate from vsl.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 9 June 2018 Resolved
999 Other (Safety General)Each Bunker Line and transfer pipe must be tested annualy and not leak under a staitic liquid pressure of at least 1.5 times the MAWP.
Condition: Invalid
Action required: 703 - Prior to bunkering operations
Due 10 August 2018
Resolved 29 August 2018
Resolution: C/E pressure tested piping on 29 Aug 2018.

Casualty record · 1

15 August 2024Routine · role: Involved in a Marine Casualty · activity 7986586
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.