THE MAGIC MERMAN

THE MAGIC MERMAN is a 2018 passenger vessel (inspected). The Coast Guard has recorded 12 inspections since 2018, most recently in May 2026, along with 12 deficiencies.

Records from 2018 to 2026. Most recent: inspection, 6 May 2026.

Built
2018
Last inspected
6 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 6 May 2026
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2018–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDK6425
1501437
Flag
UNITED STATES
Maury page id
psix-1501437

Documentation record

Registered dimensions (L × B × D)39.0 ft × 12.0 ft × 4.4 ft
Registered tonnagegross 13 / net 13
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderINVENTECH MARINE SOLUTIONS LLC · BREMERTON, WA, UNITED STATES · built 2018
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portLAHAINA, HI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 13 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Net Ton
13 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

12 inspections, each with its date, unit and type; 12 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 12

6 May 2026 Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8367739
9 April 2025 Annual Inspection · Drydock Exam
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8108567
8 April 2024 COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7890715
13 April 2023 Annual Inspection · Deficiency Check · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7667657
21 April 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7435155
15 April 2021 Drydock Exam · Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7175928
7 August 2020 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7026824
13 July 2020 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7005279
31 October 2019 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6846754
29 April 2019 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6673067
16 April 2019 DAPI Audit · Deficiency Check · Initial Certification · Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6664052
28 June 2018 Drydock Exam · Simplified Stability Test · Internal Structural Exam · Construction Oversight · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6511925

Deficiency record · 12

05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 6 May 2026 Resolved
Vessel is required to ensure the EPIRB's battery is replaced after it is used, or before the date required by FCC regulations in 47 CFR part 80, whichever comes sooner. Vessel's EPIRB battery past expiration date. Replace battery to satisfaction of attending Coast Guard Marine Inspector. Vessel restricted to within three mile of shore. Owner installed new EPIRB with valid registration during inspection. No further requirements. 46 CFR 185.728(b)
Action required: 10 - Deficiency Rectified
Resolved 6 May 2026
Resolution: New EPIRB installed
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 April 2024 Resolved
The owner or managing operator of a vessel shall ensure that the vessel complies with the laws and regulations applicable to the vessel and that the vessel is otherwise satisfactory for the intended service. The initial inspection may include an inspection of the following items: Certificates and operating manuals, including certificates issued by the FCC. FCC Safety Radio Certificate not issued by FCC licensed technician for radio installation. Provide inspection and valid FCC Safety Radio Certificate. 46 CFR 176.402
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2024
Resolved 26 April 2024
Resolution: New Safety Radio Cert provided.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 April 2023 Resolved
A space containing a fuel tank for gasoline must be equipped with a fire detection and alarm system of an approved type installed in accordance with 46 CFR part 76, except when a fixed-gas fire extinguishing system that is capable of automatic discharge upon heat detection is installed. Fire detection system could not be tested at detector head. Provide fire detection system that can be tested at detector head.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 April 2023
Resolved 21 April 2023
Resolution: New alarm panel installed and detector tested with hair dryer.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 April 2022 Resolved
Vessel does not currently meet the requirements of Work Instruction 31. Mandated crew posted on COI may not enter the water or act as lifeguard until policy and procedure provided. Provide written procedure. Prior to having mandated crew enter water. Work Instruction 31
Action required: 705 - Other - as specified
Due 21 May 2022
Resolved 30 June 2022
Resolution: Work Instruction 31 procedures provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 April 2022 Resolved
The installation of portable fire extinguishers must be in compliance with guidance on extinguisher label. Vessel had extinguisher mounted using bungee cord. Portable extinguisher shall be installed with approved bracket that is found on extinguisher label. Provide bracket for portable fire extinguisher. 46 CFR 181.520
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2022
Resolved 5 July 2022
Resolution: Bracket provided.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 15 April 2021 Resolved
EPIRB float free arrangement/hydrostatic release expired. Provide new hydrostatic release.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2021
Resolved 10 May 2021
Resolution: New hydro provided.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 15 April 2021 Resolved
Missing current navigation publications. Provide either navigation publications downloaded on 02 electronic devices or paper and kept onboard the vessel. Tide Tables, Light List, Navigation Rules, Coast Pilot.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2021
Resolved 10 May 2021
Resolution: Pubs provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 April 2021 Resolved
Drug and alcohol audit showed that supervisor and general crew member awareness training has not been completed. Crew must complete proper drug and alcohol training.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2021
Resolved 10 May 2021
Resolution: Training provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 April 2021 Resolved
Drug and alcohol audit showed that company policy statement was not on vessel. Proved copy of company drug and alcohol policy statement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2021
Resolved 10 May 2021
Resolution: Policy provided.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 13 July 2020 Resolved
Test bilge alarms in accordance with 46CFR 176.804. Bilge alarm was inoperative.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2020
Resolved 7 August 2020
Resolution: Bilge alarm operational.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 July 2020 Resolved
Inspection of portable fire extinguishers in accordance with 46 CFR 176.810. Portable fire extinguisher inspection was overdue.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2020
Resolved 7 August 2020
Resolution: Portable fire extinguishers inspected by servicing company.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 16 April 2019 Resolved
Vessel stability is currently under review by MSC. Prove compliance with applicable stability standards in accordance with 46 CFR 178.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 April 2019
Resolution: MSC issued approved stability letter.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.