Records from 2022 to 2025. Most recent: inspection, 25 July 2025.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 July 2022
Resolved
At least two SCBA's additional to those required by regulation 10.10 shall be provided. PSCO observed 01 inoperable SCBA of the 02 additional required.
74Solas(20 cons.)II-2/19.3.6.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 12 July 2022
Resolved 12 July 2022
Resolution: Regulator gasket changed. PSCO and Flag State witnessed operational test of SCBA to be fully functional. Deficiency rectified on site.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 12 July 2022
Resolved
General arrangement plans shall be permanently exhibited for the guidance of the ships officers, showing clearly for each deck the control stations, the various fire sections enclosed by "A" class divisions. PSCO observed 01 fire door to dry stores without self closing mechanisms in accordance to fire control plan.
74Solas(20 cons.)II-2/15.2.4.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 August 2022
Resolved 15 July 2022
Resolution: Mechanism installed for door to be self closing as per vessel fire control plan. See survey narrative attached in docs for class approval and pictures. Flag state audit report attached for approval.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 12 July 2022
Resolved
Structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions. PSCO observed 07 self closing doors leading to pipe and cable trunks and duct trunks on decks A, B, C, and E not latching.
74Solas(20 cons.)II-2/14.2.1.1.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 August 2022
Resolved 15 July 2022
Resolution: Fire doors adjusted to increase closing force. Attested by class survey and flag audit.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 July 2022
Resolved
The safety of passengers, crew and ship from electrical hazards will be ensured. PSCO observed 02 seperate exposed and unsecured wires in crew laundry.
74Solas(20 cons.)II-1/40.1.3
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 12 July 2022
Resolved 12 July 2022
Resolution: PSCO and Flag State witnessed removal of wires and installation of junction box. Deficiency rectified on site. See survey narrative for further documentation and pictures.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 12 July 2022
Resolved
Objective evidence discovered in an expanded ISM exam revealed the following non-conformity: The vessel failed to fully implement the requirements of the SMS as evident by DEF. 01, 02, 03, 04. An external audit is required within 30 days.
74Solas(20 cons.)IX/3
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 August 2022
Resolved 15 July 2022
Resolution: External audit conducted and found satisfactory with flag state approval. Audit report attached in docs. Release from Flag detention recieved.