Records from 2018 to 2026. Most recent: inspection, 29 May 2026.
Inspection history · 15
29 May 2026
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8383502
13 May 2026
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8372572
14 May 2025
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8140522
31 January 2025
Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8073563
28 May 2024
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7923265
16 May 2024
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7913950
20 March 2023
COI Inspection · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7653504
18 January 2023
Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7624379
29 December 2022
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7614221
17 May 2022
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7459822
17 May 2021
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7257820
24 July 2020
Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7025900
20 July 2020
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7025885
18 November 2019
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6859161
25 July 2018
Initial Certification · Drydock Exam · Simplified Stability Test
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6490270
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 May 2026
Resolved
11117 - Each ring life buoy on a vessel must be stowed in a way that it can be rapidly cast loose. The life buoy was secured to the vessel by w bungee cord.
46 CFR 180.70(b)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 May 2026
Resolution: Received photographic evidence the vessel secured the life ring to the vessel properly.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 May 2026
Resolved
11117 - Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy. The lanyard was not buoyant material resistant to ultraviolet light.
46 CFR 180.70(d)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 May 2026
Resolution: Received photographic evidence the correct lanyard was put on the float light.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 16 May 2024
Resolved
11131 - The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. There were no emergency instructions posted.
46 CFR 185.510(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2024
Resolved 28 May 2024
Resolution: Received photographic evidence the emergency instructions were posted.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 16 May 2024
Resolved
18299 - Alcohol testing must be conducted on each individual engaged or employed on board the vessel who is directly involved in the SMI. The alcohol testing of each individual must be conducted within 2 hours of when the SMI occurred. There were no alcohol test strips on board the vessel.
46 CFR 4.06-3(a)(1)(i)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2024
Resolved 28 May 2024
Resolution: Received photographic evidence alcohol test strips were on board.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 16 May 2024
Resolved
11117 - Each ring life buoy with a floating waterlight must have a lanyard of at least 3 feet in length, but not more than 6 feet, securing the waterlight around the body of the ring life buoy. Each floating waterlight must be attached to the lanyard with a corrosion-resistant clip. The clip must have a strength of at least 50 pounds, and allow the waterlight to be quickly disconnected. The floating waterlight was not attached around the life buoy with a corrosion resistant clip.
46 CFR 180.70(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2024
Resolved 30 May 2024
Resolution: Received photographic evidence the floating water light was attached with a corrosion resistant clip.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 29 December 2022
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years.
Vessel owner/operator failed to complete required drydock by 07/31/2022 as indicated on vessel COI. 46 CFR 176.600
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2024
Resolution: DDX was completed in January 2023