GELBRAY EXPRESS

GELBRAY EXPRESS is a freight ship. The Coast Guard has recorded 2 inspections in 2018, along with 11 deficiencies — 3 with no resolution recorded — and 1 operational control.

Records in 2018. Most recent: inspection, 3 December 2018.

Built
Not recorded
Last inspected
3 December 2018
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 3 December 2018
…past their stated due date3
Operational controls None recorded without a removal date
Years with a record 1 calendar year (2018)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9621211
9V5956
1503382
Flag
SINGAPORE
Maury page id
psix-1503382

Documentation record

Tonnage as PSIX records it10421 - Convention (Subpart B), Gross Ton
5225 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 2

3 December 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6635982
15 October 2018 Ballast Water Examination · PII Safety Exam · Deficiency Check · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6561240

Deficiency record · 11

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 October 2018 Resolved
11-11118-Each lifejacket shall be provided with a means of securing a lifejacket light. At least half of the vessel’s lifejackets had insufficient means for securing the lights to the lifejacket.74 SOLAS (14) 34 - LSA Code II/2.2.1.13
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2018
Resolved 17 October 2018
Resolution: Lifejacket lights attached to lifejackets by a lanyard. Satisfactory condition. Deficiency cleared.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 15 October 2018 No resolution recorded
10-15109-Suitable instructions and component spares for testing and maintenance shall be provided. Detectors shall be periodically tested using equipment suitable for the types of fires to which the detector is designed to respond. Ship’s crew used an open flame from a lighter to test flame detector. Manufacturer’s instructions require use of a test lamp. No test lamp was available on board.-74SOLAS (14) II-2/7.2.2-FSS Code 9.2.5.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 October 2018 — due date passed with no resolution recorded
Resolution: Deficiency changed from code 16 to code 50. Test lamp requisition order presented to PSCO. Vessel will procure testing equipment enroute to next port.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 October 2018 No resolution recorded
09-07199The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces, and other hazards. The top of the thermal boiler heater is warped due to excessive heat.74 SOLAS (14) II-1/26.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 October 2018 — due date passed with no resolution recorded
Resolution: Code 17 changed to code 50. Equipment tagged out per condition of class, to be permanently rectified w/in 30 days.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 15 October 2018 Resolved
08-02105-Hydraulic power-operated steering gear shall be provided with the following: a fixed storage tank having sufficient capacity to recharge at least one power actuating system including the reservoir, where the main steering gear is required to be power-operated. The steering gear reserve hydraulic tank contained insufficient fluid to recharge the main system. 74 SOLAS (14) II-1/29.12.3
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2018
Resolved 17 October 2018
Resolution: Vessel crew filled steering gear hydraulic tank. PSCO and RINA confirmed appropriate liquid level. Deficiency cleared.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 15 October 2018 Resolved
01-14104-Any ship of 10,000 gross tonnage and above shall be fitted with oil filtering equipment complying with paragraph 7 of this regulation. The electronic actuator for the OWS supply valve was broken causing the OWS system to be non-operational.MARPOL 1/14.2 (30ABC)
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 15 October 2018
Resolved 17 October 2018
Resolution: Repairs made to faulty circuitry by ship's crew. PSCO and RINA observed operation of system and three-way valve. All satisfactory. Deficiency cleared.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 15 October 2018 Resolved
02-15109-The company should establish procedures to ensure that the ship is maintained in accordance with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. In meeting these requirements, the company should ensure that: any non-conformity is reported, with its possible causes, if known; and ensure appropriate corrective action is taken. The number 2 steering pump was unable to move the rudder more than 15 degrees to starboard under bridge control and the reserve hydraulic oil tank did not contain sufficient oil to recharge the steering system. The thermal fluid heater was observed warped due to excessive heat and diesel fuel was leaking onto the hot surface. Blanks were fitted into the potable water head tank piping, rendering the relief valves nonfunctional which created a risk of over pressurization and possible rupture. The emergency generator fuel tank contained insufficient fuel and the fuel cutoff valve was found in the closed position rendering it unable to function in an emergency. Operational-related deficiencies collectively provide objective evidence of a serious failure, or lack of effectiveness, of the implementation of the ISM Code. An external audit is recommended to be conducted within 30 days by the flag state or RO to determine whether the ship is operating in accordance with the ISM Code. Provide decision to USCG prior to departing port. 74SOLAS(14)IX/3.1 & ISM Code Part A 10(30ABC)
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 15 October 2018
Resolved 17 October 2018
Resolution: Vessel elected to have an external ISM audit completed. Audit is scheduled for NPOC (Qatar) with DNV-GL. Deficiency cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 October 2018 Resolved
03-13199-Where main or auxiliary machinery including pressure vessels or any parts of such machinery are subject to internal pressure and may be subject to dangerous overpressure, means shall be provided where practicable to protect against such excessive pressure. PSCO observed blanked-off piping on hydro-pneumatic tank between pressure relief valve and holding tank not allowing excessive pressure to relieve. 74SOLAS(14)II-1/27.2 (17AC)
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 15 October 2018
Resolved 17 October 2018
Resolution: PSCO observed pipe blank removed and tank pressures within MAWP. Safety valves tested by crew in presence of RINA surveyor. All satisfactory. Deficiency cleared.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 15 October 2018 Resolved
04-02105-Where the main steering gear comprises two or more identical power units, an auxiliary steering gear need not be fitted, provided that: in a cargo ship, the main steering gear is capable of operating the rudder as required by paragraph 3.2 while operating with all power units. PSCO observed control from the bridge was unable to move rudder beyond 15° starboard.74SOLAS(14)II-1/29.6.1.2 (17AC)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 October 2018
Resolved 17 October 2018
Resolution: Chief Engineer adjusted limit switch for the steering gear. PSCO conducted full steering gear test from bridge and local controls with both #1 and #2 motors and in follow up and non-follow up. Swing of rudder from 35 degrees port to 35 degrees stbd obse
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 October 2018 No resolution recorded
05-13199-The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following shall be met: means shall be provided to control leaks of flammable liquids. PSCO observed a fuel leak from piping onto the hot surface of the boiler thermal fluid heater system. 74SOLAS(14)II-2/4.1.1 (17AC)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2018 — due date passed with no resolution recorded
Resolution: Changed from code 17 to code 50. RINA issued condition of class giving 30 days to rectify, equipment tagged out until the deficiency can be rectified permanently.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 15 October 2018 Resolved
04-04114-The electrical power available shall be sufficient to supply all those services that are essential for safety in an emergency. PSCO observed the fuel oil tank for the emergency generator had an insufficient level of fuel.74SOLAS(14)II-1/43.2 (17AC)
Action required: 17 - Rectify deficiencies prior to departure
Due 15 October 2018
Resolved 17 October 2018
Resolution: Fuel oil was added to emergency generator fuel oil tank. PSCO and RINA confirmed appropriate liquid level. Deficiency cleared.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 15 October 2018 Resolved
07-04114-Each emergency generating set arranged to be automatically started shall be equipped with starting devices approved by the administration. The fuel shut off valve for the emergency generator was found in the closed position rendering the system unable to start automatically. 74SOLAS(14)II-1/44.2 (17AC)
Action required: 17 - Rectify deficiencies prior to departure
Due 15 October 2018
Resolved 17 October 2018
Resolution: PSCO and RINA verified emergency generator fuel oil tank shutoff valve was in the open position. Deficiency cleared.