MAURY USCG vessel records
← All vessels

FLEX RANGER

FLEX RANGER is a 2018 tank ship. The Coast Guard has recorded 14 inspections since 2018, most recently in May 2025, along with 1 deficiency and 2 operational controls.

Records from 2018 to 2025. Most recent: inspection, 27 May 2025.

Built
2018
Last inspected
27 May 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 27 May 2025
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2018–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9709025
1503865
Flag
MARSHALL ISLANDS
Maury page id
psix-1503865

Documentation record

Tonnage as PSIX records it115174 - Convention (Subpart B), Gross Ton
115174 - Regulatory (Subpart C or D), Gross Ton
34860 - Convention (Subpart B), Net Ton
34860 - Regulatory (Subpart C or D), Net Ton
88684 - Dead Weight, Metric Ton
123410 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 14

27 May 2025 PSC B · COC-GAS Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8135640
2 July 2024 PSC B · COC-GAS Annual
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7935436
30 October 2023 Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7824865
4 May 2023 PSC B · COC-GAS Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7676924
12 January 2022 PSC B · COC-GAS Annual
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7373791
19 April 2021 Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7178400
7 December 2020 PSC B · COC-GAS Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7105685
25 April 2020 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6944501
20 November 2019 Ballast Water Examination · COC-GAS Annual · ISPS II Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6856492
11 August 2019 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6779459
8 June 2019 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6707229
7 June 2019 Type not recorded
No type recorded · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 6743927
6 March 2019 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6635745
12 November 2018 COC-GAS Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6576850

Deficiency record · 1

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 12 November 2018 Resolved
Gas detection systems provided in accordance with the requirements of this chapter shall activate the alarm at 30% LFL and shut down the master gas fuel valve at not more than 60% LFL. While conducting gas detection test of the master gas valves in the GVU room, the master gas valves did not close at 60% LFL. - 40ac - (Solas 74(2014) Ch. VII, Reg. 13.1 - IGC Code (2016) Ch. 16, Reg. 16.4.8
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 12 November 2018
Resolved 19 February 2019
Resolution: MSU Port Arthur had meeting with Flag State inspector. System diagrams were submitted showing the Gas detection system was designed to have 2 gas detectors reach 60% LEL before the MGVs close. System will be reconfigured to have one detector reach 60% LEL

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.