MAURY USCG vessel records
← All vessels

COSCO SHIPPING PEONY

COSCO SHIPPING PEONY is a freight ship. The Coast Guard has recorded 7 inspections since 2018, most recently in March 2026, along with 2 deficiencies.

Records from 2018 to 2026. Most recent: inspection, 9 March 2026.

Built
Not recorded
Last inspected
9 March 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 9 March 2026
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2018–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9785744
1504026
Flag
HONG KONG
Maury page id
psix-1504026

Documentation record

Tonnage as PSIX records it145042 - Dead Weight, Metric Ton
46115 - Convention (Subpart B), Net Ton
144927 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 7

9 March 2026 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8322986
5 June 2024 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7927669
19 March 2024 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7881717
30 August 2022 PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7538152
23 February 2021 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7144656
7 August 2019 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6775480
10 July 2018 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6473846

Deficiency record · 2

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 July 2018 Resolved
EXAMINATION OF THE CO2 ROOM FOUND NUMEROUS CONNECTIONS TO CO2 BOTTLES TO BE HAND-TIGHT.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 July 2018
Resolved 10 July 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 July 2018 Resolved
EXAM OF STEERING GEAR FOUND A FLANGE/CONNECTION ON THE #2 STEERING GEAR AT FREATER THAN 1 DROP PER SECOND.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 July 2018
Resolved 10 July 2018

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.