Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it162761 - Convention (Subpart B), Gross Ton 102211 - Convention (Subpart B), Net Ton 307663 - Dead Weight, Metric Ton 352003 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 5
21 April 2024COC-TVE Annual
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7893476
30 January 2023COC-TVE Renew · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7629052
15 October 2021PSC B · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7333088
10 September 2019COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6796270
18 September 2018COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6540426
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 April 2024Resolved
In tankers, electrical equipment, cables and wiring shall not be installed in hazardous locations unless it conforms with standards not inferior to those acceptable to the organization. PSCO observed 03 cracked lights in the pumproom and on deck, and the 02 ESD installations with exposed wiring going into electrical box.
74 SOLAS (20) II-1/45.11
34ac (Operations Restricted)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 April 2024
Resolved 22 April 2024
Resolution: vessel submitted class report attesting to the rectification of the deficiencies.
02 - Structural Conditions › N/A - No Subsystem › Cargo tank vent system
Issued 15 October 2021Resolved
Openings for pressure relief valves shall have as great a height as practicable above cargo tank deck to obtain maximum dispersal of flammable vapors, but in no case less than 2m above the cargo deck. PSCO's observed excessive cargo vapours escaping from the vacuumside of #4 center P/V valve.
Action required: 10 - Deficiency Rectified
Due 15 October 2021
Resolved 15 October 2021
Resolution: Crew reseated vacuum side of P/V valve.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.