Records from 2000 to 2020. Most recent: inspection, 20 August 2020.
Inspection history · 20
20 August 2020
Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7038490
29 September 2010
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3859330
19 September 2010
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3854427
27 September 2007
Ballast Water Examination · MARPOL Annex V Examination · Random ISPS/MTSA/PSC · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3067272
27 September 2007
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3067616
28 February 2007
MARPOL Annex I Examination · PII Safety Exam · ISPS II Exam · MARPOL Annex V Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2876533
12 September 2006
ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 2776189
8 September 2006
Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2773158
5 September 2006
Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2769208
4 September 2006
Ballast Water Examination · Enhanced Seaway Inspection (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2764934
4 September 2006
Joint Vessel Security Verification (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2764937
4 September 2006
Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2768687
8 April 2005
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2329222
15 December 2004
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2260083
15 December 2004
ISPS I Exam
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2260088
10 December 2004
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2256973
30 November 2004
ISPS II Exam · NPV Safety Exam · Ballast Water Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2250817
18 November 2003
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1950376
27 June 2002
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1640011
6 October 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 282847
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 27 September 2007
Resolved
Oily Water Separator's fresh water/oily mixture valve and piping has been modified. Vessel could not provide evidence of approval from administration or class society. Prior to departure the vessel is required to have the administration or class society verify that the modifications comply with Mapol Annex I REG. 14.6
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 22 October 2012
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 28 February 2007
No resolution recorded
fire door in engine room not self closing as required by SOLAS 74 amended regulation 47.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolution: PSCO verified that engine room doors were self closing. Deficiency rectified.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 28 February 2007
Resolved
Vessels Echo Depth Sounder is inoperable in violation of 33 CFR 164
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 September 2007
Resolution: PSCO attested and verified that vessels echo depth sounder is operational . Deficiency has been rectified.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 28 February 2007
Resolved
vessel failed to request letter of deviation for inoperable echo depth sounder as required by 33 CFR 164.53
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 March 2007
Resolution: Vessel requested Letter of Deviation to sail.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 12 September 2006
Resolved
Echo Depthsounder inop. To repair in drydock prior to next US. Port.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 1 August 2007
Resolution: PSCO attested and verified that vessels echo depth sounder is operational. Deficiency has been rectified
Fire Fighting › Means of Escape › Doorways
Issued 30 November 2004
Resolved
Lower engine room emergency escape door does not automaticly close. SOLAS 74/78 Chapter II-2 regulation 47
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 December 2004
Resolved 8 April 2005
Resolution: CLEARED VIA CLASS
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 30 November 2004
Resolved
Engine room entrance does not fully close. SOLAS 74/78 Chapter II-2 regulation 47
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 December 2004
Resolved 8 April 2005
Resolution: CLEARED VIA CLASS
Stability › Weathertight Integrity › General
Issued 30 November 2004
Resolved
Bridge and emergency generator doors had holdbacks installed. SOLAS Chapter 74/78 Chapter II-2 regulation 47
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 December 2004
Resolved 8 April 2005
Resolution: CLEARED VIA CLASS