MAURY USCG vessel records Sign in
← All vessels

KAHUNA-NUI

KAHUNA-NUI is a 1983 passenger vessel (inspected). The Coast Guard has recorded 15 inspections since 2000, most recently in April 2009, along with 16 deficiencies.

Records from 2000 to 2009. Most recent: inspection, 6 April 2009.

Built
1983
Last inspected
6 April 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDB2765
Flag
UNITED STATES
366879530 (licence lapsed)
Maury page id
psix-15051

Inspections, by type

…with no type recorded1
Years with a record 9 calendar years (2000–2009)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it8 - Simplified, Gross Ton
6 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDB2765MMSI 366879530 · expired · compulsorily equipped · granted 24 January 2003, cancelled 30 March 2013
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 15

6 April 2009 Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3447504
16 October 2007 Re-Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3080273
30 May 2007 Hull Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2946582
15 June 2006 In-Service Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2680807
13 June 2006 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2678116
17 November 2005 COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2536253
24 June 2005 Hull Examination · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2208334
11 May 2004 Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2064899
28 February 2003 Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1751832
19 February 2003 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1745896
2 October 2002 Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1683141
8 January 2002 Re-Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1478438
21 June 2001 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1403408
3 January 2001 Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1449389
2 October 2000 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1058208

Deficiency record · 16

Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 16 October 2007 Resolved
Provide up to date required navigation publications.
Action required: 705 - Other - as specified
Due 16 November 2007
Resolved 16 November 2007
Communications › Alarms/Indicators › High Water Alarm
Issued 16 October 2007 Resolved
Prove proper operation of the port high water alarm.
Action required: 705 - Other - as specified
Due 16 November 2007
Resolved 4 December 2007
Resolution: Received a call from owner stating the port high water alarm is operational.
Engineering › Bilge Water Management System › Pump
Issued 15 June 2006 Resolved
Repair bilge alarm in Port pontoon to indicate high level audiable and visual at the main operating station.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 June 2006
Resolved 20 June 2006
Resolution: Bilge wiring was chafed. New cable ran and bilge alarm tested sat.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 15 June 2006 Resolved
Replace two lifejackets condemned by CG inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 June 2006
Resolved 20 June 2006
Resolution: Both lifejackets replaced and marked with vessel name.
Documentation › Logs/Records › Drug Test Records
Issued 15 June 2006 Resolved
Deckhand has current consortium card but needs to be added to current list of enrolled employees.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 June 2006
Resolved 20 June 2006
Resolution: Faxed copy of new crew list obtained.
Construction/Loadline › Hull › Bottom Plating
Issued 12 October 2004 Resolved
CROP AND RENEW AREAS OF WASTED BOTTOM PLATE IN BOTH HULL AS MARKED, PROVIDE REPAIR PROPOSAL FOR PLATE AND KEEL TUBE RENEWAL FOR APPROVAL PRIOR TO COMMENCING REPAIRS.
Action required: 705 - Other - as specified
Due 12 November 2004
Resolved 24 June 2005
Resolution: COMPLETE NEW BOTTOM PLATE INSTALLED ON BOTH HULLS DURING 7 MONTH REPAIR PERIOD.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 May 2004 Resolved
Repair nav lights (port and stbd).
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 May 2004
Resolved 12 May 2004
Resolution: Bulb replaced.
Lifesaving › Lifejacket/PFD (Type I)
Issued 11 May 2004 Resolved
Provide six (6) adult PFD's which inspector destroyed. LEGACY COMPONENT DESC: Quantity
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2004
Accommodation/Occupational Safety › Medical/First Aid
Issued 11 May 2004 Resolved
Provide new asprin and eye wash. LEGACY COMPONENT DESC: Medicine Chest
Action required: 705 - Other - as specified
Due 31 May 2004
Resolved 25 May 2004
Electrical › Electric Supply System (service)
Issued 11 May 2004 Resolved
Secure battery boxes to deck and re-new crimp on positive battery connection. LEGACY COMPONENT DESC: Battery Installation
Action required: 705 - Other - as specified
Due 31 May 2004
Resolved 25 May 2004
Fire Fighting › Miscellaneous Items
Issued 11 May 2004 Resolved
Provide location labels for out of view portable fire extinguishers under console and in head space.
Action required: 705 - Other - as specified
Due 31 May 2004
Resolved 25 May 2004
Lifesaving › Lifebuoys
Issued 11 May 2004 Resolved
Provide new retroreflective tape on life ring.
Action required: 705 - Other - as specified
Due 31 May 2004
Resolved 25 May 2004
Communications › Radio Communications
Issued 19 February 2003 Resolved
RENEW EPIRB HYDROSTATIC RELEASE. LEGACY COMPONENT DESC: EPIRB
Due 9 March 2003
Resolved 28 February 2003
Lifesaving › Lifebuoys
Issued 19 February 2003 Resolved
PROVIDE BOUYANT/ UV RESISTANT LINE FOR RING BOUY LIGHT. LEGACY COMPONENT DESC: Buoyant Lifeline
Due 9 March 2003
Resolved 28 February 2003
Construction/Loadline › Hull
Issued 2 October 2002 Resolved
PLUG WELD FIVE (5) 1/4" HOLES ON BOTTOM KEEL TUBE LEGACY COMPONENT DESC: Collision Strap
Action required: 705 - Other - as specified
Due 4 October 2002
Resolved 4 October 2002
Resolution: PLUG WELDS WITNESSED. REPAIR SAT.
Construction/Loadline › Hull › Weld
Issued 2 October 2002 Resolved
REPAIR SUPERFICIAL FRACTURES ON EXISTING WELDS, BOTH RUDDERS.
Action required: 705 - Other - as specified
Due 4 October 2002
Resolved 4 October 2002
Resolution: NEW WELD BEAD APPROX. 3" LONG COMPLETED ON BOTH RUDDERS. WITNESSED REPAIR, ALL SAT