Records from 2018 to 2026. Most recent: inspection, 19 February 2026.
Documentation record
Registered dimensions (L × B × D)31.5 ft × 13.0 ft × 4.2 ft
Registered tonnagegross 8 / net 8
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderARMSTRONG MARINE USA INC · PORT ANGELES, WA, UNITED STATES · built 2018
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portHONOKOHAU, HI
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 17 July 2025 · expires 31 August 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it8 - Simplified, Gross Ton
8 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 14
19 February 2026
Internal Structural Exam · Drydock Exam
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8316701
6 October 2025
Administrative Inspection · Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8249148
17 October 2024
Deficiency Check · Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8021354
1 October 2024
Examination of Repairs · Internal Structural Exam · Drydock Exam · Damage Survey
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8013445
11 July 2024
Damage Survey · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7956376
10 October 2023
Internal Structural Exam · Deficiency Check · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7805080
27 September 2022
Drydock Exam · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7567234
30 November 2021
Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7359464
28 April 2021
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7188636
20 October 2020
Internal Structural Exam · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7081028
1 September 2020
In-Service Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7047807
12 September 2019
Internal Structural Exam · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6807815
18 October 2018
Administrative Inspection · DAPI Audit · COI Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6564803
23 April 2018
Administrative Inspection · Drydock Exam · Inclining Experiment · Construction Oversight
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6511880
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 6 October 2025
Resolved
Certificate of Documentation (COD) not available for inspection. Must provide proof of current COD.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2025
Resolved 8 October 2025
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 October 2024
Resolved
High level bilge alarm not indicating visual and audio at the operator's station for the following spaces:
-stbd aft space
-port aft space
Must make repairs to satisfaction of USCG Marine Inspector. Must check both spaces and log prior to getting underway with passengers until deficiency is rectified.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 November 2024
Resolved 20 November 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 October 2024
Resolved
Electrical bilge pump not indicating visual when running at the operator's station for the following space:
-port aft space
Must make repairs to satisfaction of USCG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 November 2024
Resolved 20 November 2024
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 17 October 2024
Resolved
Must provide cowl for mechanical exhaust system that extends to the deck plate in the port fuel tank space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 November 2024
Resolved 20 November 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 October 2024
Resolved
Must install proper label, block letters at least 2" on contrasting colors, on stowage bin with lifejackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 November 2024
Resolved 20 November 2024
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 1 October 2024
Resolved
Identified pitted areas around the keel in the following spaces: Fwd aux spaces port/stbd sides, Fwd fuel tank space port side, aft fuel tank space stbd side. Must re assess marked areas and repair all pitted areas exceeding 25% wastage to the satisfaction of the USCG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2024
Resolved 20 November 2024
Resolution: Extension granted due to travel lift at the dry-dock being inoperable.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 10 October 2023
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. The portside engineroom blower did not energize and is not serviceable. Vessel rep must replace blower.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 October 2023
Resolved 11 October 2023
Resolution: A new blower was installed and tested, sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 October 2023
Resolved
A flammable vapor detection system must provide a visual and audible alarm at the operating station. Detector not operational, must replace and test with CG inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 October 2023
Resolved 11 October 2023
Resolution: A new fume detector was installed, tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 October 2023
Resolved
A red warning sign at the switch must state that the blowers must be operated prior to starting the engines for the time sufficient to insure at least one complete change of air in the space served, placard is black and white on printed paper, must install placard in accordance with requirement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2023
Resolved 11 October 2023
Resolution: A red placard was installed IAW regulation, all sat.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 10 October 2023
Resolved
Except as provided in 80.13(c), stations must have an authorization granted by the Federal Communications Commission. Vessel could not produce current FCC station license during annual inspection and the radio telephony certificate was expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2023
Resolved 11 November 2023
Resolution: FCC License was onboard and the Radio Telephony Certificate was updated and uploaded in MISLE.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 10 October 2023
Resolved
Portable watertight containers for distress flares and smoke signals shall be of a bright color, and containers shall be clearly marked in legible contrasting letters at least 12.7 millimeters (0.5 inches) high: “DISTRESS SIGNALS”. The container was black in color, must replace container with correct bright color and label properly.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2023
Resolved 11 October 2023
Resolution: Vessel rep supplied a bright orange watertight box with proper labeling, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 October 2023
Resolved
Each life jacket must be marked in clearly legible block capital letters with the vessel's name. Ten life jackets were missing the vessel's name, provide proper marking and identification on all life jackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2023
Resolved 11 October 2023
Resolution: All life jackets were properly labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 September 2022
Resolved
An adult life jacket must be provided for each person
carried on board a vessel. One life jacket was cracked
and in unserviceable condition. Provide additional life
jacket in serviceable condition. Vessel is restricted to
16 persons total due to lack of properly outfitted
lifejackets.
46 CFR 180.71
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2022
Resolved 30 September 2022
Resolution: New replacement lifejacket provided on board.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 September 2022
Resolved
The Certificate of Inspection issued to a vessel
describes the vessels minimum manning requirements and
any equivalences accepted or authorized by the cognizant
[name withheld] required deckhand enters the water during
in water diving activities as the vessel’s COI is
endorsed for Work Instruction 31. The vessel does not
have AED pads as required by Work Instruction 31.
Provide AED pad.
46 CFR 176.103
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2022
Resolved 21 October 2022
Resolution: New child and adult AED pads provided for on board AED.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 November 2021
Resolved
Shutoff valves at the tank must be manually operable from outside. Both remote fuel shutoff valve did not work.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 December 2021
Resolved 2 December 2021
Resolution: Support guide correctly attached allowing remote fuel shutoffs operations.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 November 2021
Resolved
Inspection of each portable fire extinguisher, semi-portable fire extinguisher, and fixed gas fire extinguishing system to check for excessive corrosion and general condition. Fixed FM 200 material condition is questionable due to salt water corrosion.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2021
Resolved 2 December 2021
Resolution: Fixed fire extinguisher exterior cleaned and in serviceable condition.