MISS TEMPIE is a 2018 passenger vessel (inspected). The Coast Guard has recorded 12 inspections since 2018, most recently in February 2026, along with 7 deficiencies.

Records from 2018 to 2026. Most recent: inspection, 18 February 2026.

Built
2018
Last inspected
18 February 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 18 February 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2018–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDL7885
1507942
Flag
UNITED STATES
Maury page id
psix-1507942

Documentation record

Registered dimensions (L × B × D)54.0 ft × 22.0 ft × 5.9 ft
Registered tonnagegross 58 / net 47
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderUS WORKBOATS · HUBERT, NC, UNITED STATES · built 2018
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeBox
Hull configurationMonohull
Hailing portDAVIS, NC
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 4 August 2026 · expires 30 September 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it58 - Simplified, Gross Ton
47 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 12

18 February 2026 COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8307986
6 March 2025 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8089183
30 January 2025 Drydock Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8072065
27 February 2024 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7871622
12 February 2024 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7864485
19 January 2023 Hull Examination · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7623815
15 August 2022 In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7543486
13 August 2022 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7584080
9 March 2022 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7403250
12 May 2021 Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7194993
2 April 2021 Appeal
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7167663
6 July 2018 Construction Oversight · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6469505

Deficiency record · 7

07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 27 February 2024 Resolved
Piping used in a vital system must: (1) Be composed of ferrous materials except when: (i) Nonmetallic piping materials are permitted by § 182.720; or (ii) Nonferrous metallic piping materials are permitted by § 182.730. Remove the existing section of flexible hose within the fire main discharge piping and install proper materials and prove proper operation.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2024
Resolved 7 March 2024
Resolution: Approved non-metallic piping provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 27 February 2024 Resolved
In addition to meeting the requirements of paragraphs (a) through (e) of this section, a vessel with a power driven main steering gear must be provided with the following: (2) An independent rudder angle indicator at the operating station. Rudder angle indicator is noted to be offset during operation test. Make effective repairs.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2024
Resolved 13 March 2024
Resolution: Rudder angle indicator has been reset and operates as intended.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 February 2024 Resolved
A vessel is inspected for compliance with the standards required by this sub-chapter. Fire hose found leaking at the fitting. Renew in kind.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2024
Resolved 7 March 2024
Resolution: New fire hose provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 February 2024 Resolved
Spanner wrenches must be provided where a 40 millimeter (1.5 inch) diameter firehose is required by § 181.320(b). Install 02 Spanner wrenches at the fire station.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2024
Resolved 7 March 2024
Resolution: Spanner wrenches provided.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 2 March 2023 Resolved
Each ring life buoy on a vessel must: Be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150; current ring buoy was deteriorated, cracked and line was not to pull test strength. Replace with a in-kind ring buoy IAW COI.
Action required: 705 - Other - as specified
Due 9 March 2023
Resolved 9 March 2023
Resolution: Operator replaced life ring.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 2 March 2023 Resolved
Each battery used in an item of lifesaving equipment, except inflatable survival craft equipment, must be replaced during the annual inspection if the expiration date of the battery has passed. Waterlight battery was expired. Replace battery with in-kind battery.
Action required: 705 - Other - as specified
Due 9 March 2023
Resolved 9 March 2023
Resolution: Operator replaced battery. All SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 March 2023 Resolved
Life preservers shall be of first-class workmanship and shall be free from any defects materially affecting their appearance or serviceability. 01 adult life jacket was burnt exposing foam material. Provide new adult life jacket as per COI.
Action required: 705 - Other - as specified
Due 9 March 2023
Resolved 9 March 2023
Resolution: Operator procured an in-kind life jacket. All SAT.

Ownership record