MAURY USCG vessel records Sign in
← All vessels

NOS TERRA

NOS TERRA is a 1959 freight ship. The Coast Guard has recorded 7 inspections since 2000, most recently in February 2003, along with 60 deficiencies — 21 with no resolution recorded —.

Records from 2000 to 2003. Most recent: inspection, 5 February 2003.

Built
1959
Last inspected
5 February 2003
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

5203970 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
CAMBODIA
—
Maury page id
psix-15112

Inspections, by type

…with no type recorded4
…past their stated due date21
Years with a record 4 calendar years (2000–2003)
The 7 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 23 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it1024 - Regulatory (Subpart C or D), Gross Ton
473 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 7

5 February 2003 Type not recorded
No type recorded · MSFO NEW BEDFORD · USCG Northeast District (CGD-NE) · Activity 2087740
2 January 2003 Annual Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1725229
11 December 2002 Security Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1717416
14 March 2002 Annual Inspection
Physical examination · MSFO NEW BEDFORD · USCG Northeast District (CGD-NE) · Activity 1492647
2 February 2001 Type not recorded
No type recorded · MSFO NEW BEDFORD · USCG Northeast District (CGD-NE) · Activity 286857
18 October 2000 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 283170
9 September 2000 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 281937

Deficiency record · 60

Fire Fighting › Fire Pumps
Issued 2 January 2003 No resolution recorded
Vessel fire pump pressure gauge was installed but inoperable, replace with operable gauge. LEGACY COMPONENT DESC: Pressure
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 2 January 2003 — due date passed with no resolution recorded
Construction/Loadline › Hull › Girder
Issued 2 January 2003 No resolution recorded
Overall strenghth of hull girder suspect. No main deck wastage percentage documented at last gauging survey. Glass determine over all percentage of wastage.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 January 2003 — due date passed with no resolution recorded
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 20 December 2002 No resolution recorded
Vessel lost anchor while at anchorage due to wx. Replace anchor. Vessel has one operable anchor
Condition: Damaged By Earlier Event
Action required: 15 - Rectify deficiencies by next port
Due 20 December 2002 — due date passed with no resolution recorded
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 20 December 2002 No resolution recorded
Vessel main diesel engine exhaust manifold was missing exhaust heat shield blankets exposing hot surfaces to crew. Blankets where missing or inadiquate.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 December 2002 — due date passed with no resolution recorded
Engineering › Diesel Engine (propulsion-electric) › Piping (exhaust)
Issued 20 December 2002 No resolution recorded
Vessel A/C generator prime mover exhaust pipe was holed just after manifold.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 20 December 2002 — due date passed with no resolution recorded
Electrical › Electrical Distribution System (service) › Cable
Issued 20 December 2002 No resolution recorded
Vessel A/C generator main power supply cable is unsupported and improperly installed. Cable is hanging from generator along bulkheads and improperly connected to power distribution panel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 December 2002 — due date passed with no resolution recorded
Engineering › Sea-water System (primary cooling) › Valve
Issued 20 December 2002 No resolution recorded
Vessel high sea suction valve has excessive leakage of seawater. Repair or replace.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 December 2002 — due date passed with no resolution recorded
Construction/Loadline › Hull › Hull Plating
Issued 20 December 2002 No resolution recorded
Main deck fractured starboard side way of frame number 50.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 December 2002 — due date passed with no resolution recorded
Construction/Loadline › Hull › Hull Plating
Issued 20 December 2002 No resolution recorded
Vessel tween deck wasted cargo hold number 1 starboard side aft corner of cargo opening.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 December 2002 — due date passed with no resolution recorded
Navigation › Piloting/Steering
Issued 14 March 2002 Resolved
No Tidal Current Table Publication onboard LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 April 2002
Resolution: Vessel Agent provided
Lifesaving › Lifebuoys
Issued 14 March 2002 Resolved
Portside Lifebuoy Light Inoperative LEGACY COMPONENT DESC: Self-igniting Lights
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 April 2002
Resolution: Received and intsalled new light 8 April 2002
Lifesaving › Inflatable Liferafts
Issued 14 March 2002 Resolved
Port & Starboard Liferaft Releases past expiration date LEGACY COMPONENT DESC: Hydrostatic Release Unit
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 April 2002
Resolution: Received, and installed new Hydrostatic Releases 8 April 2002
Lifesaving
Issued 14 March 2002 Resolved
EPIRB Hydrostatic Release past expiration date LEGACY COMPONENT DESC: EPIRB
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 April 2002
Resolution: Received and installed new Hydrostatic Release 8 April 2002
Lifesaving › Line-Throwing Appliances
Issued 14 March 2002 Resolved
Line Throwing Appliance missing 3 (three) projectiles LEGACY COMPONENT DESC: Projectiles
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 April 2002
Resolution: Received new Line Throwing Appliances 8 April 2002
Electrical › Electrical Distribution System (service)
Issued 14 March 2002 Resolved
Open wires in forward line locker LEGACY COMPONENT DESC: Wiring
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 April 2002
Resolution: wires properly covered
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 14 March 2002 Resolved
Numerous Fire Extinguishers need service throughout vessel LEGACY COMPONENT DESC: Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 April 2002
Resolution: Extinguishers serviced 20 March by Southeastern Fire Equipment, inc
Lifesaving › Lifebuoys
Issued 14 March 2002 Resolved
Replace Lifebouy Starboard Stern LEGACY COMPONENT DESC: Quantity
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 April 2002
Resolution: Received new lifebuoys from Life Raft & Survival 8 April 2001
Fire Fighting › Fire Pumps
Issued 14 March 2002 Resolved
Renew Fire Pump Gauge
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 April 2002
Resolution: Installed new Fire Pump gague
Pollution Prevention/Response › Prevention Equipment
Issued 14 March 2002 No resolution recorded
Install new gague to prove proper operation of O.W.S. prior to next U.S. port call. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 15 - Rectify deficiencies by next port
Due 30 June 2002 — due date passed with no resolution recorded
Lifesaving › Lifejacket/PFD (General)
Issued 14 March 2002 Resolved
Replace Life Jacket lights as needed LEGACY COMPONENT DESC: Lights
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 April 2002
Resolution: Received and installed 14 new lights 8 April 2002
Fire Fighting › Self-contained Breathing Apparatus
Issued 14 March 2002 Resolved
Service Fire Fighting Breathing Apparatus per class
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 April 2002
Resolution: SCBA cylinders hydrostatically tested 9 apr 2002 and refilled
Fire Fighting
Issued 2 February 2001 Resolved
SOLAS 60 II/65(C)2_x001C_ 4 FIREFIGHTING NOZZELS WASTED. 6 REQUIRED.
Condition: Unknown
Due 8 March 2001
Resolved 8 March 2001
Construction/Loadline
Issued 2 February 2001 No resolution recorded
ILLC 66 ANNEX 1/1 1_x001C_ MAINDECK THINNED; WASTED; PINHOLED; STARBOARD CARGO HOLD #2
Condition: Unknown
Due 1 March 2001 — due date passed with no resolution recorded
Construction/Loadline
Issued 2 February 2001 No resolution recorded
ILLC 66 ANNEX 1/1 1_x001C_ FRACTURED HATCH FWD GIRDER HOLD #2 PORT/STARBOARD
Condition: Unknown
Due 1 March 2001 — due date passed with no resolution recorded
Construction/Loadline
Issued 2 February 2001 No resolution recorded
ILLC 66 ANNEX 1/1 1_x001C_ #2 CARGO HOLD DOUBLE BOTTOM TANK TOP BUCKLED
Condition: Unknown
Due 1 March 2001 — due date passed with no resolution recorded
Construction/Loadline
Issued 2 February 2001 No resolution recorded
ILLC 66 ANNEX 1/1 1_x001C_ MAIN DECK BUCKLED FWD OF CARGO HOLD #1 PORT/STARBOARD
Condition: Unknown
Due 1 March 2001 — due date passed with no resolution recorded
Construction/Loadline
Issued 2 February 2001 No resolution recorded
ILLC 66 ANNEX 1/1_x001C_ EXCESSIVE DOUBLER INSERTS ON THE STERN IMMEDIATELY BELOW RUB-RAIL.
Condition: Unknown
Due 1 March 2001 — due date passed with no resolution recorded
Construction/Loadline
Issued 2 February 2001 No resolution recorded
ILLC 66 ANNEX 1/1 1_x001C_ BULKWARKS DETACHED / FRACTURED IN NUMEROUS LOCATIONS PORT/STARBOARD.
Condition: Unknown
Due 1 March 2001 — due date passed with no resolution recorded
Construction/Loadline
Issued 2 February 2001 No resolution recorded
ILLC 66 ANNEX 1/1 1_x001C_ #2 HOLD HATCH COMBING FRACTURED.
Condition: Unknown
Due 1 March 2001 — due date passed with no resolution recorded
Construction/Loadline
Issued 2 February 2001 No resolution recorded
ILLC 66 ANNEX 1/1 1_x001C_ CEMENT PATCH WAY OF ROSE BOX #2 CARGO HOLD, ON HULL BOTTOM PLATE.
Condition: Unknown
Due 1 March 2001 — due date passed with no resolution recorded
Fire Fighting
Issued 2 February 2001 Resolved
SOLAS 60 II/65_x001C_ FIRE BOX WASTED PORT HOUSE.
Condition: Unknown
Due 8 March 2001
Resolved 8 March 2001
Construction/Loadline
Issued 2 February 2001 Resolved
ILLC 66 ANNEX 1/1 1_x001C_ MAIN DECK STRB DECK HOUSE CORNER FWD WATSED THRU.
Condition: Unknown
Due 8 March 2001
Resolved 8 March 2001
Construction/Loadline
Issued 2 February 2001 Resolved
ILLC 66 ANNEX 1/1 1_x001C_ CABLE RUN STARBOARD MAIN DECK FRACTURED / BROKEN OFF/
Condition: Unknown
Due 20 February 2001
Resolved 20 February 2001
Electrical
Issued 2 February 2001 Resolved
SOLAS 60 II 27(A)_x001C_ MISSING NON-CONDUCTIVE RUBBER MAT IN FRONT OF ENGINEROOM SWITCHBOARD.
Condition: Unknown
Due 8 March 2001
Resolved 8 March 2001
Navigation
Issued 2 February 2001 Resolved
33 C.F.R. 164.33 2_x001C_ CHARTS NOT CURRENTLY CORRECTED.
Condition: Unknown
Due 8 March 2001
Resolved 8 March 2001
Construction/Loadline
Issued 2 February 2001 Resolved
ILLC 66 ANNEX 1/1 1_x001C_ FRAME UNDERDECK BRAKETS TRIPPED/FRACTURED, HOLD #2.
Condition: Unknown
Due 8 March 2001
Resolved 8 March 2001
Navigation
Issued 2 February 2001 Resolved
33 C.F.R. 164.33 2_x001C_ MISSING COAST PILOT #2.
Condition: Unknown
Due 8 March 2001
Resolved 8 March 2001
Construction/Loadline
Issued 2 February 2001 Resolved
ILLC 66 ANNEX 1/1 1 _x001C_ HOLE 1/2"X1/2" WASTED THRU UNDERDECK LONGITUDINAL WAY OF CARGO HOLD #1 PORTSIDE.
Condition: Unknown
Due 8 March 2001
Resolved 8 March 2001
Lifesaving
Issued 2 February 2001 Resolved
SOLAS 60 III 17(B)_x001C_ PILOT LADDER LENGHT INSUFFICENT.
Condition: Unknown
Due 1 March 2001
Resolved 9 March 2001
Lifesaving
Issued 2 February 2001 Resolved
SOLAS 60 III/19(B)(1)_x001C_ EMBARKATION LADDER ROPES DETERIORATED.
Condition: Unknown
Due 1 March 2001
Resolved 9 March 2001
Construction/Loadline
Issued 2 February 2001 No resolution recorded
ILLC 66 ANNEX 1/1 1_x001C_ 1" HOLE THRU MAIN DECK WAY OF #2 CARGO HOLD.
Condition: Unknown
Due 1 March 2001 — due date passed with no resolution recorded
Construction/Loadline
Issued 2 February 2001 No resolution recorded
ILLC 66 ANNEX 1/1 1_x001C_ MAIN DECK FRACTURED 4"-5" WAY OF CARGO HOLD #2, PORT AFT DECK RADIUS.
Condition: Unknown
Due 1 March 2001 — due date passed with no resolution recorded
Construction/Loadline
Issued 2 February 2001 Resolved
ILLC 66 ANNEX 1/1_x001C_ TWEEN DECK STANTION WASTED THRU BOTTOM WAY OF HOLD #1 STBD.
Condition: Unknown
Due 8 March 2001
Resolved 8 March 2001
Unknown
Issued 2 February 2001 Resolved
N
Condition: Unknown
Due 8 March 2001
Resolved 8 March 2001
Construction/Loadline
Issued 9 September 2000 Resolved
CARGO HATCHES ARE NOT WEATHERTIGHT ON #1 & #2 CARGO TANKS
Condition: Unknown
Due 19 September 2000
Resolved 2 October 2000
Electrical
Issued 9 September 2000 Resolved
EMERGENCY SOURCE OF POWER ON BRIDGE IS INOPERABLE.(BATTERY CABLE IS CUT)
Condition: Unknown
Due 19 September 2000
Resolved 2 October 2000
Fire Fighting
Issued 9 September 2000 Resolved
FIRE SAFETY PLAN IS OUT OF DATE, VSL HAS ONLY ONE COPY IN MASTER'S CABIN.
Condition: Unknown
Due 2 January 2001
Resolved 2 January 2001
Accommodation/Occupational Safety
Issued 9 September 2000 Resolved
INSECTS FOUND IN GALLEY AND STORAGE SPACES.
Condition: Unknown
Due 19 September 2000
Resolved 14 September 2000
Construction/Loadline
Issued 9 September 2000 Resolved
MAIN DECK STARBOARD SIDE HOLED IN WAY OF #1 CARGO HOLD.
Condition: Unknown
Due 19 September 2000
Resolved 2 October 2000
Construction/Loadline
Issued 9 September 2000 Resolved
WATERTIGHT DOOR FOR FORCASTLE WASTED.
Condition: Unknown
Due 19 September 2000
Resolved 2 October 2000
Accommodation/Occupational Safety
Issued 9 September 2000 No resolution recorded
TIE TOILET IN MASTER'S CABIN TO MSD HOLDING TANK
Condition: Unknown
Due 15 January 2001 — due date passed with no resolution recorded
Fire Fighting
Issued 9 September 2000 Resolved
EMERGENCY FIRE PUMP IS INOPERABLE.
Condition: Unknown
Due 19 September 2000
Resolved 2 October 2000
Fire Fighting
Issued 9 September 2000 Resolved
FIRE EXTINGUISHER IN GALLEY IS OUT OF SERVICE.
Condition: Unknown
Due 19 September 2000
Resolved 2 October 2000
Engineering
Issued 9 September 2000 Resolved
PRODUCE OIL TRANSFER PROCEDURES IAW WITH 33CFR 155.720.
Condition: Unknown
Due 19 September 2000
Resolved 2 October 2000
Lifesaving
Issued 9 September 2000 Resolved
REPLACE 2 LIFE BOUYS ON FIRST DECK AFT, PORT & STBD.
Condition: Unknown
Due 19 September 2000
Resolved 2 October 2000
Unknown
Issued 9 September 2000 Resolved
PROVIDE STANDARD OIL DISCHARGE CONNECTION.
Condition: Unknown
Due 19 September 2000
Resolved 2 October 2000
Electrical
Issued 9 September 2000 Resolved
BATTERIES IN ENGINE ROOM NEED TO BE SECURED.
Condition: Unknown
Due 19 September 2000
Resolved 2 October 2000
Fire Fighting
Issued 9 September 2000 Resolved
PROVIDE A FIXED FIRE FIGHTING SYSTEM IN ENGINE ROOM.
Condition: Unknown
Due 19 September 2000
Resolved 2 October 2000
Construction/Loadline
Issued 9 September 2000 Resolved
FRACTURES IN WAY OF #2 CARGO HOLD HATCH COMBING FORWARD
Condition: Unknown
Due 19 September 2000
Resolved 2 October 2000
Documentation
Issued 9 September 2000 Resolved
VESSEL IS NOT IN COMPLIANCE WITH IT'S SAFE MANNING DOCUMENT. 1 MOTORMAN IS MISSING.
Condition: Unknown
Due 19 September 2000
Resolved 2 October 2000

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.