MAURY USCG vessel records
← All vessels

NACC ARGONAUT

NACC ARGONAUT is a 2003 freight ship. The Coast Guard has recorded 13 inspections since 2018, most recently in October 2025, along with 10 deficiencies.

Records from 2018 to 2025. Most recent: inspection, 3 October 2025.

Built
2003
Last inspected
3 October 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 3 October 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2018–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9287302
1517635
Flag
CANADA
Maury page id
psix-1517635

Documentation record

Tonnage as PSIX records it9255 - Convention (Subpart B), Gross Ton
13357 - Dead Weight, Ton
18336 - Displacement, Ton
3517 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 13

3 October 2025 Deficiency Check · In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8245790
28 August 2025 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8219634
18 August 2025 In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8212627
6 May 2025 PSC B
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8128633
29 January 2025 Deficiency Check · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8071757
21 October 2024 PSC B
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8019993
3 May 2023 Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7848778
26 March 2022 Canadian Vsl Safety Exam (D9 only)
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7417075
7 December 2020 Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7107751
22 September 2020 PSC A · Administrative Inspection · Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7062053
1 June 2020 Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6965360
27 July 2019 Canadian Vsl Safety Exam (D9 only)
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6763721
23 July 2018 Canadian Vsl Safety Exam (D9 only)
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6487979

Deficiency record · 10

14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management System (BMWS)
Issued 28 August 2025 Resolved
The master, owner, operator, agent, or person in charge of a vessel equipped with ballast tanks that operates in the waters of the United States must employ one of the following ballast water management methods: Install and operate a ballast water management system (BWMS) that has been approved by the Coast Guard under 46 CFR 162. Vessel reported inoperable Ballast Water Treatment System. 33 CFR 151.2025 (a)(1)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 September 2025
Resolved 20 November 2025
Resolution: Recieved satisfactory class report attesting to repairs of BWMS.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 21 October 2024 Resolved
Fixed fire detection and alarm systems shall be periodically tested to the satisfaction of the Administration by means of equipment having the appropriate range of density, particle size, or other phenomena associated to which the detector is designed. Observed ship's crew using propane torch to trigger flame detector over No. 1 generator, stating they lack the appropriate testing equipment. 74 SOLAS (20) II/ 7.3.2 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 29 January 2025
Resolved 29 January 2025
Resolution: Received Class documentation for repair
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 21 October 2024 Resolved
The arrangement and equipment of the catering department in every ship shall be such as to permit the service of proper meals to the members of the crew. Observed frozen meat locker refrigeration unit iced over due to malfunction and filling a 5 gallon bucket with frozen condensation.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 29 January 2025
Resolved 29 January 2025
Resolution: Received Class documentation for repair
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 21 October 2024 Resolved
Each life raft or group of life rafts shall be stowed with a float free arrangement complying with the requirements of paragraph 4.1.6 of the code. PSCO observed 03 float free life rafts with their painter line connected to the life raft cradle.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 21 October 2024
Resolution: Corrected on the spot. Painter lines connected to break away device.
07 - Fire Safety › N/A - No Subsystem › Jacketed high pressure lines and oil leakage alarm
Issued 22 September 2020 Resolved
External high-pressure fuel delivery lines shall be provided with an alarm in case of fuel line failure. Port State Control Officer requested test of oil leak alarm and was informed system not installed. 74SOLAS(04)II-2/4.2.2.5.2
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 23 September 2020
Resolved 12 October 2020
Resolution: System was rectified and tested in presence of attending class surveyor. Class report received.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 22 September 2020 Resolved
Internal combustion engines of 2250 Kw and above shall be provided with crank case Oil Mist Detectors. Oil mist detectors on main diesel engine (MDE), 4250Kw, was unplugged and not operational. 74SOLAS(04)II-1/47.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 23 September 2020
Resolved 12 October 2020
Resolution: Oil mist sensors were renewed and system tested to the satisfaction of attending class surveyor. Class report received.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 22 September 2020 Resolved
Means shall be provided to control leaks of flammable liquid. PSCO observed fuel oil soaked lagging on each oil purifier, and excessive leaking from the fuel lines under the MDE jacket hood, with sorbent material tied down to control leaks. 74SOLAS(04)II-2/4.1.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 23 September 2020
Resolved 12 October 2020
Resolution: Lagging renewed, leakage from FO lines below jacket hood has been rectified and sorbent material removed. Class report received.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 22 September 2020 Resolved
Doors required to be self closing shall not be fitted with hold back devices, unless they are fail safe remote release. Multiple doors in the main ladder well and engine room, were held back with hooks, and the emergency escape ladder well from the engine room held open by rope. 74SOLAS(04)II-2/9.4.2.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 23 September 2020
Resolved 12 October 2020
Resolution: Tie backed doors have been freed, inspected by class surveyor. Class report received.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 22 September 2020 Resolved
The steering gear compartment shall be provided with suitable arrangements to ensure safe working access in the event of a hydraulic oil leak, to include hand rails, and gratings, or other non-slip arrangements. Area around steering gear had no railing or non- slip arrangements. 74SOLAS(04)II-1/29.13.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2020
Resolved 12 October 2020
Resolution: Railing has been installed. Satisfactorily inspected by attending surveyor. Class report recieved.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 September 2020 Resolved
A portable foam applicating unit shall consist of a portable foam tank with at least 20L of foam concentrate and at least one spare tank of the same capacity. Portable foam applicator unit starboard of the MDE missing required spare tank. 74SOALS(04)II-2/10.3.1 FSS/4.3.2.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2020
Resolved 20 October 2020
Resolution: Vessel recieved spare tank on board and provided picture.

Ownership record