MAURY USCG vessel records
← All vessels

PATTY L

PATTY L is a 1977 freight barge. The Coast Guard has recorded 34 inspections since 1997, most recently in December 2025, along with 66 deficiencies and 1 operational control.

Records from 1997 to 2025. Most recent: inspection, 9 December 2025.

Built
1977
Last inspected
9 December 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 9 December 2025
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 22 calendar years (1997–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDC3993
152007
Flag
UNITED STATES
Maury page id
psix-152007

Documentation record

Registered dimensions (L × B × D)110.3 ft × 30.1 ft × 6.6 ft
Registered tonnagegross 193 / net 193
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSOUTHERN BARGE INC · BUTTE LAROSE LA, UNITED STATES · built 1977
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portHOUMA, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 6 May 2026 · expires 30 June 2027
Service, as the file records itFreight Barge
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it193 - Regulatory (Subpart C or D), Net Ton
193 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

34 inspections, each with its date, unit and type; 66 deficiencies with the resolution recorded against each; 1 operational control with the dates imposed and removed; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 34

9 December 2025 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8273407
4 September 2025 Drydock Exam · Cargo Tank Internal · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8227388
27 December 2024 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8050373
14 November 2023 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7818558
7 February 2023 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7633183
11 August 2022 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7531065
8 February 2022 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7392412
21 January 2021 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7128600
12 February 2020 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6907326
15 November 2018 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6579767
8 January 2018 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6335041
8 November 2017 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6303526
28 December 2016 Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6063234
2 November 2015 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5757712
4 February 2015 Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5063279
10 December 2013 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4766262
13 November 2012 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4491031
2 October 2012 Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4454517
29 February 2012 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4252526
9 November 2010 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3887254
2 March 2010 MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3687826
5 June 2009 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3528359
8 December 2008 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3378912
20 November 2008 Administrative Inspection · In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3366640
12 October 2007 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3078647
28 June 2007 Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2976929
30 August 2006 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2764252
9 November 2005 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2563605
23 September 2004 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2203135
22 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1973334
4 June 2003 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1809719
27 March 2003 COI Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1764411
18 September 2002 Hull Examination
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1668740
20 November 1997 Type not recorded
No type recorded · USCG Heartland District (dp) · USCG Heartland District (CGD-H) · Activity 644789

Deficiency record · 66

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 December 2025 Resolved
The Owner/Master shall ensure vessel’s fire fighting equipment is ready at all times. 160BC wheel extinguisher gauge reading no pressure. Serviced 20OCT25. 46 CFR 97.15-60
Action required: 10 - Deficiency Rectified
Due 9 December 2025
Resolved 9 December 2025
Resolution: Third-party attended, changed out a seal, and recharged to satisfactory condition.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 9 December 2025 Resolved
The position of the rudder must be shown at the principal steering station. RAI at steering station inoperable. 46 CFR 113.40-5
Action required: 10 - Deficiency Rectified
Due 9 December 2025
Resolved 9 December 2025
Resolution: Third-party attended, troubleshot, and got the RAI operating in satisfactory condition.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 14 November 2023 Resolved
An inspection for certification is required to determine, among other things, that the vessel is in compliance with the Federal Communication Commission regulations. Vessel doesn't have a valid Bridge-to-Bridge Certificate and MMSI programmed into it's communication system and must have both prior to operation. 46 CFR 91.25-10 (Old "I")
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 November 2023
Resolution: Bridge to Bridge Cert procured and GPS data appropriately programmed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 14 November 2023 Resolved
Installation of all systems of a marine engineering nature, including steering system, must be in accordance with 46 CFR, Subchapter F. Vessel's steering rudder must be fixed to be able to steer 30 degrees to 35 degrees on both sides. 46 CFR 96.03-1 (Old "I")
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 November 2023
Resolution: Rudder operational through full range of motion required.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 November 2023 Resolved
The installation of all systems of an electrical engineering nature must be in accordance with 46 CFR, Subchapter J. Portside high-level water alarm is triggering high lube-oil pressure and water temperature indicators in the wheel-house alarm panel and must be fixed prior to operation. 46 CFR 96.05-1 (Old "I")
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 November 2023
Resolution: Alarms fixed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 November 2023 Resolved
The installation of all systems of a marine engineering nature shall be in accordance with the requirements in 46 CFR Subchapter F. Vessel's main generator emergency shutdown is inoperable and must be fixed prior to operation. 46 CFR 96.03-1 (Old "I")
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 November 2023
Resolution: E-stops operational
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 November 2023 Resolved
Each ring life buoy must be constructed in accordance with 46 CFR 160.050. Drain plug of portside life ring buoy must be replaced to ensure it's serviceability. 46 CFR 94.43-5 (Old "I")
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 November 2023
Resolved 15 November 2023
Resolution: Plug replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 November 2023 Resolved
The installation of all systems of an electrical engineering nature must be in accordance with 46 CFR Subchapter J. Wiring support in the machinery space and throughout the vessel must be supported in metal hangers or straps. 46 CFR 96.05-1 (Old "I")
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2023
Resolved 16 November 2023
Resolution: Deficiencies addressed.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 14 November 2023 Resolved
A fire control plan that clearly show general arrangement of fire protection must be submitted to the Coast Guard for approval. Vessel didn't have a CG approved plan onboard and must submit one that complies with CG regulations. 46 CFR 91.55-1 (Old "I")
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2023
Resolved 21 December 2023
Resolution: Fire control plan updated and approved.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 14 November 2023 Resolved
The installation of all systems of an electrical engineering nature must be in accordance with 46 CFR Subchapter J. Portside propulsion tachometer on the bridge is inoperable and must be fixed. 46 CFR 96.05-1 (Old "I")
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2023
Resolved 15 November 2023
Resolution: Deficiency rectified.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 November 2023 Resolved
Each panel board must have a circuit directory that has the circuit designation of each circuit, a description of the load of each circuit, and the rating or setting of the over-current protective device for each circuit. Panel boards throughout the vessel were missing required circuit directory and must be labeled accordingly. 46 CFR 111.40-11 (Old "J")
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2023
Resolved 16 November 2023
Resolution: Distribution panels labeled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 November 2023 Resolved
The construction and installation of all systems of a marine engineering nature must be in accordance with 46 CFR Subchapter F. Vessel's pressure vessel missing stamp/nameplate must be replaced. 46 CFR 96.03-1 (Old "I")
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2023
Resolved 28 November 2023
Resolution: Dataplate cleaned off and legible.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 November 2023 Resolved
The construction and installation of all systems of a marine engineering nature must be in accordance with 46 CFR Subchapter F. A number of oil hoses are cotton jacketed type and must be replaced with hoses that meet SAE J1942 standards. 46 CFR 96.03-1 (Old "I")
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2023
Resolved 15 November 2023
Resolution: Flexible hoses in lube oil system changed for SAEJ 1942 hoses.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 14 November 2023 Resolved
The general construction of the vessel must be such as to minimize fire hazards. Original fire protection insulation inside berthing space is wasted and must be replaced in kind. 46 CFR 92.05-1 (Old "I")
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2023
Resolved 28 November 2023
Resolution: Insulation replaced.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 February 2022 Resolved
Navigation lights must be wired by heavy duty flexible cord to a watertight receptacle outlet. Nav light STBD wiring exposed/damaged.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2022
Resolved 10 February 2022
Resolution: Witnessed new installation.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 8 February 2022 Resolved
Vent outlets must be fitted with a single screen of corrosion resistant wire of 30x30 mesh or two screens 20x20. Fuel vent screen is punctured.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2022
Resolved 10 February 2022
Resolution: Witnessed new installation.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 8 February 2022 Resolved
All exposed cargo hatches and other openings in the hull are closed and made properly watertight. Port side emergency hatch was not watertight; daylight was exposed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 March 2022
Resolved 10 February 2022
Resolution: Repair has been made to make watertight.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 February 2022 Resolved
Having a float-free link that is proper strength for size and number of lifefloat attached to the float-free link. Lifefloat was missing a weak link and float free arrangement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2022
Resolved 14 February 2022
Resolution: Purchased new weak link and installation for life float.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 21 January 2021 Resolved
The vessels port rudder stock or associated components was not of adequate strength, causing an ingress of water onto the deck. Repair or replace rudder stock or associated components.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 January 2021
Resolved 25 January 2021
Resolution: Vessel replaced the grease on the port rudder stock. Conducted full operational test. All sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 January 2021 Resolved
Vessel has failed to follow approved vessel response plan and has not conducted or documented QI notification exercises, which may be conducted quarterly. Provide record of conducted QI exercise.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2021
Resolved 25 January 2021
Resolution: Vessel corrected QI exercises drill sheet.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 21 January 2021 Resolved
Strong and effective rudder stops must be fitted. Rudder stops were wasted. Repair or replace wasted rudder stops.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2021
Resolved 25 January 2021
Resolution: Welder was hired and repaired rudder stops.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 January 2021 Resolved
Electric installations on vessels must ensure: protection of passengers, crew, other persons, & the vessel from electric hazards.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2021
Resolved 28 January 2021
Resolution: Electrical issues resolved.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 12 February 2020 Resolved
Vessels has failed to follow approved vessel response plan and has not conducted or documented Qualified Individual (QI) notification exercises, which must be conducted quarterly as per 33CFR155.1060;Provide record of conducted QI exercise
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 March 2020
Resolved 2 March 2020
Resolution: Provided documentaion of QI drill
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 February 2020 Resolved
Vessel has failed to follow approved vessel response plan and has not conducted annual exercise either a tabletop or oil spill removal organization deployment as per 33CFR155.1060; Provide documentation of conducted exercise.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 March 2020
Resolved 19 June 2020
Resolution: Provided documentation for annual drill and confirmation from OSRO
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 January 2018 Resolved
Navigation light failure unable to make audible/visual alarm.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 January 2018
Resolved 10 January 2018
Resolution: VSL rep provided documentation showing the navigation light failure successfully produced an audible/visual alarm.
Navigation › Piloting/Steering › Marine Charts
Issued 28 December 2016 Resolved
Vessel is required to carry up to date nautical publicatons and charts. Vessel found with no current charts of nautical publications for route. Correct prior to sailing.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 January 2017
Resolved 5 January 2017
Resolution: New charts onboard.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 28 December 2016 Resolved
Vessels subject to 33CFR155.1035 must conduct drills quarterly to test QI notification procedures and contact information and shipboard emergency procedures for oil pollution incidents. Vessel has not conducted drills at appropriate intervals. DEF will remain open until next annual inspection to verify drills are conducted and logged at appropriate intervals.
Action required: 705 - Other - as specified
Resolved 8 January 2018
Resolution: VSl provided log books with drills logged appropriately.
Communications › Audible Communications › Horn/Whistle
Issued 28 December 2016 Resolved
Vessels of more than 12m must be fitted with a whistle. Vessel's whistle is malfunctioning.
Action required: 705 - Other - as specified
Due 4 January 2017
Resolved 5 January 2017
Resolution: Whistle replaced and tested Sat.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 28 December 2016 Resolved
Master shall ensure that each crane is operated and maintained in accordance with API RP 2D. Has has not kept records of inspections, testing, or maintence of crane. DEF will remain open until next annual inspection to verify crane is being inspcted properly and inspections are documented properly.
Action required: 705 - Other - as specified
Resolved 12 February 2020
Resolution: Vsl provided annual test records for crane testing
Deck/Cargo › Cargo Stowage › General
Issued 28 December 2016 Resolved
Vessels has exceeded CTIE dates by 3 years. Vessel has agreed to conducting UT testing of cargo tank bottoms every 5 years. Provide UT report prior to using cargo tanks.
Action required: 705 - Other - as specified
Due 4 January 2017
Resolved 5 January 2017
Resolution: Received UT report and attended vessel inspected tank all sat.
Communications › Alarms/Indicators › General Alarm
Issued 2 November 2015 Resolved
General alarm not working in the engine room and the pump house and no strobe provided for either location.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 November 2015
Resolved 2 November 2015
Resolution: Repaired alarm and installed strobe in both locations.
Electrical › Electric Supply System (service) › Battery Installation
Issued 2 November 2015 Resolved
Battery missing battery box in pump house on STBD generator.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 November 2015
Resolved 2 November 2015
Resolution: Added a battery box.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 November 2015 Resolved
Anchor light not properly mounted.
Condition: Improper/Lack of Maintenance
Due 9 November 2015
Resolved 2 November 2015
Resolution: Rewelded mount
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 2 November 2015 Resolved
Improperly installed MSD secondary holding tank.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 December 2015
Resolved 2 November 2015
Resolution: corrected piping for the secondary holding tank.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 November 2015 Resolved
Improper wiring of fan in engine room overhead.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 November 2015
Resolved 2 November 2015
Resolution: Wiring has been repaired.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 10 December 2013 Resolved
Alcohol test strips expired.
Due 20 December 2013
Resolved 16 December 2013
Resolution: replaced alcohol test stips
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 10 December 2013 Resolved
Hand rail on the port and stbd corners of the bridge wings severely corroded.
Due 13 December 2013
Resolved 12 December 2013
Resolution: cropped and renewed the corroded sections of hand rail.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 10 December 2013 Resolved
port main engine exhaust lagging torn.
Due 13 December 2013
Resolved 12 December 2013
Resolution: repaired exhaust lagging
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 10 December 2013 Resolved
generator exhaust lagging/heat protection missing.
Due 13 December 2013
Resolved 12 December 2013
Resolution: provided heat protection for generator exhaust.
Lifesaving › Lifefloat › Serviceable
Issued 10 December 2013 Resolved
the outer covering of the life float is torn
Action required: 17 - Rectify deficiencies prior to departure
Due 14 January 2014
Resolved 14 January 2014
Resolution: Repaired covering of life raft.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 10 December 2013 Resolved
No duct covering provided for engine room exhaust vent.
Due 31 December 2013
Resolved 14 January 2014
Resolution: Installed covers for the engine room exhaust vents.
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 10 December 2013 Resolved
No data on air reciever and U1A unavailable.
Action required: 705 - Other - as specified
Due 31 December 2013
Resolved 17 December 2013
Resolution: Provided U1-A.
Construction/Loadline › Hull › Side Shell
Issued 2 October 2012 Resolved
Reviewed report of U/T, identified areas of excessive wastage on port side exceeding 25%. Area approx 6' by 4' to be renewed.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2012
Resolution: Hull insert completed and welds inspected. No call out.
Lifesaving › Visual Distress Signals (General) › Not on Board
Issued 9 November 2010 Resolved
Required to keep three red hand flares and three orange smokes onboard. Vsl did not have any onboard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 November 2010
Resolution: Purchased proper number of distress signals.
Construction/Loadline › Structures › Door
Issued 8 December 2008 Resolved
WTD to e/r was wasted along the bottom and needs repair.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 December 2008
Resolution: Door repaired by c/r wasted metal and welding in new flat bar along gasket ridge.
Deck/Cargo › Holds/Tanks › Cargo Tank Arrangement/Size
Issued 8 December 2008 Resolved
Cargo tanks were not adequately secured for transport of liquids.
Action required: 705 - Other - as specified
Resolved 12 December 2008
Resolution: Tank supports engineered to accomodate liquid load were reviewed/approved from MSC. Supports were installed on the tanks IAW agreement between owner and OCMI.
Fire Fighting › Means of Escape › Handrails/Handholds
Issued 8 December 2008 Resolved
E/R escape ladder on port side not adequate to enable easy escape.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 December 2008
Resolution: New ladder rungs added and old ones replaced where necessary.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 20 November 2008 Resolved
Vessel must proceed directly to Hot Energy Dock in Houma LA. Vessel may not operate until a COI inspection has been conducted by a CG Marine Inspector. Vessel's COI expired on 11 Aug 2008.
Action required: 705 - Other - as specified
Resolved 12 December 2008
Resolution: Inspection for Certification completed for vessel, temp COI issued.
Accommodation/Occupational Safety › Cooking Systems › Cooking Fuel
Issued 12 October 2007 Resolved
Label Stove Disconnect for Galley Range.
Due 12 November 2007
Resolved 19 October 2007
Resolution: Labeled Galley Range disconnect.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 12 October 2007 Resolved
Secure all large appliances in Galley (refrigerator, microwave, water station etc.)
Due 12 November 2007
Resolved 19 October 2007
Resolution: Secured all appliances.
Navigation › Piloting/Steering › Marine Charts
Issued 12 October 2007 Resolved
Provide current/updated navigation charts.
Due 12 November 2007
Resolved 19 October 2007
Resolution: Provided current navigation charts.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 12 October 2007 Resolved
Install blank in bridge breaker box.
Due 12 November 2007
Resolved 19 October 2007
Resolution: Installed blank in breaker box.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 12 October 2007 Resolved
Demonstrate proper operation of fire detection system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 October 2007
Resolution: Attending Marine Inspector verified operation of fire detection system.
Engineering › Diesel Engine (propulsion-direct drive) › Gear, Timing
Issued 12 October 2007 Resolved
renew RPM gauge for Port MDE on bridge.
Due 12 November 2007
Resolved 19 October 2007
Resolution: Renewed gauge.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 12 October 2007 Resolved
Install machinery guards on MDE's.
Due 12 November 2007
Resolved 15 October 2007
Resolution: Attending marine inspector verified installation of machinery guards.
Lifesaving › Lifefloat › Painter
Issued 12 October 2007 Resolved
Install painter and light on lifefloat.
Due 12 November 2007
Resolved 19 October 2007
Resolution: Installed painter and light on lifefloat.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 12 October 2007 Resolved
Log all drills and pre-underway checks in ships log.
Due 12 November 2007
Resolved 19 October 2007
Resolution: Captain verified correction of log books.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 23 September 2004 Resolved
Missing up to date Navigation publictions.
Condition: Improper/Lack of Maintenance
Due 21 October 2004
Resolved 9 November 2005
Documentation › Certificates/Documents › Stability Letter
Issued 23 September 2004 Resolved
Company lost Stability letter.
Condition: Improper/Lack of Maintenance
Due 21 October 2004
Resolved 23 September 2004
Resolution: Provided certified copy of letter.
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 September 2004 Resolved
Wiring around battery boxes sloppy and poses tripping hazard.
Condition: Improper/Lack of Maintenance
Due 21 October 2004
Resolved 3 November 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 September 2004 Resolved
Remove plug ends for permanently mounted MSD and battery chargers and properly wire into a circuit and box.
Condition: Improper Installation
Due 21 October 2004
Resolved 3 November 2004
Electrical
Issued 27 March 2003 Resolved
Diagram and installation not MSC approved
Due 11 November 2003
Resolved 22 January 2004
Resolution: Verified the installation of emergency battery backup power for Radar, Nav Lights and Emergency Lights IAW MSC approval letter for Electrical system
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 27 March 2003 Resolved
Vessel has 2 inch piping on both the high and low-pressure side of the Thermal Fluid heating system. The pipe was classified as class 1 piping by the CFR that does not allow for threaded fittings. LEGACY COMPONENT DESC: Piping
Condition: Improper Installation
Due 28 March 2003
Resolved 30 September 2003
Resolution: Approval letter for Oil Treatment Piping by MSC iaw ANSI B31.3 standard allowed threaded fittings.
Deck/Cargo › Cargo Heating
Issued 27 March 2003 Resolved
Missing limit sensor to prevent Thermal Fluid Heater from going over 291 degrees.
Due 22 January 2004
Resolved 22 January 2004
Resolution: Installed Limit sensor certified at 291 degrees with CG Boilers seal to prevent tampering.
Stability › Incline Test
Issued 27 March 2003 Resolved
Deadweight survey conducted in order to issue Stability letter for vessel.
Due 7 August 2003
Resolved 7 August 2003
Resolution: Completed Deadweight survey and was issued stability letter from MSC.
Deck/Cargo › Cargo Heating
Issued 27 March 2003 Resolved
Provide approval letter of testing procedures for Thermal Fluid Heater and show proper testing of the system LEGACY COMPONENT DESC: Testing Procedures
Due 1 December 2003
Resolved 1 December 2003
Resolution: Received approval letter from MSC for the test procedures and witnessed all the tests satisfactorily.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.