← All vessels
L/B 101 SELECT
Offshore Supply Vessel · Offshore class · Built 1970s · USCG Heartland District (CGD-H) · Other hulls named L/B 101 SELECT
L/B 101 SELECT is a 1977 offshore supply vessel. The Coast Guard has recorded 39 inspections since 1990, most recently in August 2023, along with 57 deficiencies and 1 casualty investigation in 2023.
Records from 1990 to 2023. Most recent: inspection, 21 August 2023.
- Built
- 1977
- Last inspected
- 21 August 2023
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 57 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2023
Identity
585803
WDE7530
152543
Flag
UNITED STATES
366742890, 367394360 (licence lapsed)
Maury page id
psix-152543
Inspections, by type
…with no type recorded6
Years with a record
22 calendar years (1990–2023)
The 39 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.
Documentation record
Registered dimensions (L × B × D)46.0 ft × 18.1 ft × 4.6 ft
Registered tonnagegross 45 / net 40
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderELEVATING BOATS INC · CAERNARVON, LA, UNITED STATES · built 1977
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBELLE CHASSE, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 25 August 2026 · expires 31 August 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it45 - Regulatory (Subpart C or D), Gross Ton
40 - Regulatory (Subpart C or D), Net Ton
40 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDE7530MMSI 367394360 · expired · voluntarily equipped · granted 7 February 2009, cancelled 13 April 2019 · licensed under a name not among this hull’s recorded names (not shown)
WAH9204MMSI 366742890 · expired · compulsorily equipped · granted 15 January 1998, cancelled 19 February 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 39
21 August 2023
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7816474
31 May 2019
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6699353
25 August 2018
Type not recorded
No type recorded · USCGC SAILFISH (WPB 87356) · USCG Northeast District (CGD-NE) · Activity 6522821
5 July 2018
Examination of Repairs · Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6458401
5 June 2017
Administrative Inspection · Examination of Repairs · Plan Review (Other than "T") · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6166479
18 March 2016
Examination of Repairs · Deficiency Check · COI Inspection · Drydock Exam · Internal Structural Exam · MTSA/ISPS Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5834329
6 March 2014
Annual Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4806666
22 February 2012
Deficiency Check · Drydock Exam · Internal Structural Exam · Annual Inspection · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4245526
25 February 2011
Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3951105
30 December 2008
COI Inspection · Hull Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3383624
1 November 2007
Examination of Repairs · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3089057
2 February 2007
Deficiency Check · Examination of Repairs · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2866122
16 April 2004
Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2045335
5 November 2002
Administrative Inspection
Administrative · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1701298
24 October 2002
Annual Inspection · Hull Examination
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1695278
18 April 2000
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1049310
14 January 2000
Re-Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1381773
23 October 1998
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1446696
30 October 1997
Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1383687
31 October 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1388155
23 October 1996
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1434470
20 December 1995
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1385600
30 January 1995
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1380154
27 October 1994
COI Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1429951
2 June 1994
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1164450
23 February 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 852963
30 November 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 666060
21 October 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 214176
21 October 1993
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 644364
21 October 1993
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1394005
19 October 1993
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 171311
23 November 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 830053
13 October 1992
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1267803
24 July 1992
Inclining Experiment
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 957489
28 January 1992
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1315575
21 October 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 942818
18 December 1990
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 903736
19 November 1990
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1243857
1 February 1990
Initial Certification · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 916443
Deficiency record · 57
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 31 May 2019
Resolved
Vessels tilt alarm did not sound when vessel listed more that 2 degress. Tilt alarm shall be repaired prior to using jacking system.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 5 July 2018
Resolved
Operation of transmitters of any ship station must be performed by a person holding a commercial radio operator license or permit of the class required below. No crew member on board had FCC operators permit.
47 CFR 80.155
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 5 July 2018
Resolved
Stations in the maritime service must be licensed by the FCC either individually or by fleet. Vessel did not have station license on board.
47 CFR 80.13(a)
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Health protection, medical care?)
Issued 5 July 2018
Resolved
Each EAP education program must include at least the following elements: display and distribution of informational material; display and distribution of a community service hot-line telephone number for crew member assistance, and display and distribution of the employer's policy regarding drug and alcohol use in the workplace. Vessel did not have EAP info displayed.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 5 July 2018
Resolved
Natural vents connected to the engine room and deck-house should have weather-tight closures that are appropriately marked, "close in case of fire". renew gasket to engine room closure.
46 CFR176.25-1(a) old-t
CG-543 Policy
letter 07-02
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 July 2018
Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy. Found waterlight Secured to throw line, re-attach around body of ring life buoy.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 5 July 2018
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: A space with a through-hull fitting below the deepest load waterline; A machinery space bilge; and A space with a non-watertight closure. Vessel hydraulic tank lvl alarm was not working properly.
07 - Fire Safety › N/A - No Subsystem › Jacketed high pressure lines and oil leakage alarm
Issued 5 July 2018
Resolved
In accordance with standards acceptable to the OCMI as
as good marine practice. Observed fuel leak on auxiliary
engine outboard fuel injector.
46 CFR176.25-1
Documentation › Markings/Placards › Official Number (US)
Issued 5 June 2017
Resolved
Vessel name was not on the vessel.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 5 June 2017
Resolved
AL test strips expired.
Documentation › Manuals/Policy Documentation › Operations Manual (Incinerator)
Issued 5 June 2017
Resolved
Liftboat ops manual was for a prior company and vsl name. Update and resubmitt for approval.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 5 June 2017
Resolved
Expired
Documentation › Certificates/Documents › FCC SSL
Issued 5 June 2017
Resolved
Missing
Documentation › Certificates/Documents › FCC SSL
Issued 5 June 2017
Resolved
No crewmember onboard the FCC liscence.
Communications › Alarms/Indicators › Collision Alarm
Issued 5 June 2017
Resolved
Tilt alarm for 1.2* not working. Remove toggle switch to disable alarms.
Stability › Watertight Integrity › General
Issued 5 June 2017
Resolved
Hole from old pipe in stbd sideshell.
Navigation › Piloting/Steering › Marine Charts
Issued 5 June 2017
Resolved
Provide charts of correct scale and NTM.
Engineering › Fuel Oil Service System › Valve
Issued 5 June 2017
Resolved
Stbd fuel shutoff not working.
Engineering › Engine Controls (Electric/Electronic) › Linkage
Issued 18 March 2016
Resolved
Linkage for throttle control has complete fracture at main engine.
Lifesaving › Lifefloat › Serviceable
Issued 18 March 2016
Resolved
Life float has severe damage on underside. Repair/replace as necessary. After repairs, ensure grab line is properly routed around life float body, not lifeline.
Electrical › Electric Generation Source (service) › Generator
Issued 18 March 2016
Resolved
Generator windings are coated with dirt and oil. Identify source of oil and repair/clean as necessary
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 18 March 2016
Resolved
Anchor chain has severe wastage coming off of anchor. Replace as necessary.
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 18 March 2016
Resolved
Port side hydraulic gear box is leaking. Deck has no containment. Fix hydraulic leaks.
Construction/Loadline › Penetrations › Weld
Issued 18 March 2016
Resolved
Repair exhaust leaks on main engine piping and wastage where exhaust passes thru deck.
Lifesaving › Lifebuoys › Serviceable
Issued 18 March 2016
Resolved
Ring buoy is missing plug. Check with manufacturer, determine repair/replacement options to ensure vessel has functional life ring. Additionally, float light should have appropriate corrosion resistant clip for connecting to life ring.
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 18 March 2016
Resolved
Aft and port windows on bridge have spiderweb cracks. Replace with approved glass.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 March 2016
Resolved
Port and starboard navigation lights are improperly installed. Reposition lights for proper visibility in accordance with Nav Rules
Electrical › Electric Supply System (service) › Cable
Issued 18 March 2016
Resolved
02 Junction boxes in engine room lacking appropriate covers. Replace/cover boxes as needed.
Electrical › Electric Supply System (service) › Cable
Issued 18 March 2016
Resolved
Wiring harness above Main Engine has melted cover. Replace wiring as necessary.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type 1
Issued 18 March 2016
Resolved
Type 1 MSD currently installed on liftboat is only approved for uninspected vessels. Device is not compliant with SUB J or F.
Communications › Alarms/Indicators › Bilge Alarm
Issued 22 February 2012
Resolved
Prove proper operation of bilge alarm.
Fire Fighting › Fire Pumps › Pressure
Issued 22 February 2012
Resolved
Fire pump must meet requirement of 60psi.
Electrical › Electric Supply System (service) › Cable
Issued 3 March 2011
Resolved
Provide electrian report, removal of splices and install junction box for bilge alarm and pump wiring.
Electrical › Electric Supply System (service) › Cable
Issued 3 March 2011
Resolved
Fix visual indication on low hydraulic oil alarm
Electrical › Electric Supply System (service) › Battery Charger
Issued 2 March 2011
Resolved
Hardwire battery chargers, no extension cords shall be used for permenant electrical installations.
Engineering › Fuel Oil Service System › Piping
Issued 2 March 2011
Resolved
Provide supports for fuel lines, attach lines to longitudials by brackets or other means to reduce vibration damage.
Lifesaving › Lifejacket/PFD (Type III) › Quantity
Issued 25 February 2011
Resolved
Replace type 3 lifejacket with type 1 or 2.
Communications › Radio Communications
Issued 24 October 2002
Resolved
Provide current FCC radio station license. LEGACY COMPONENT DESC: VFH Radiotelephone
Documentation › Certificates/Documents
Issued 24 October 2002
Resolved
Provide original COI for the vessel. LEGACY COMPONENT DESC: Certificate of Inspection
Engineering
Issued 14 January 2000
Resolved
Install fuel shut-off valve on supply line at ship service gen.
Electrical
Issued 14 January 2000
Resolved
Install blanks in generator distribution panel.
Engineering
Issued 14 January 2000
Resolved
Install lagging or shield on main diesel engine exhaust.
Deck/Cargo
Issued 14 January 2000
Resolved
Install hydraulic supply hose meeting ASME J-1942 with ends meeting SAE J- 1475 for hydraulic crane.
Engineering
Issued 14 January 2000
Resolved
Install fuel shut-off valves with reach rods located out side of the comp. for each fuel tank supply valve.
Lifesaving
Issued 14 January 2000
Resolved
Provide and install retro tape on ring bouy.
Navigation
Issued 14 January 2000
Resolved
Provide updated navigation pubs.
Lifesaving
Issued 14 January 2000
Resolved
Provide and install retro tape on life boat.
Construction/Loadline
Issued 23 October 1996
Resolved
Replace sump tank hose to pipe connections on deck and provide double hose clamps.
Navigation
Issued 23 October 1996
Resolved
Provide chart of operating area, tide tables, and 46 CFR 166-199.
Lifesaving
Issued 23 October 1996
Resolved
Provide retro reflective tape for resue boat.
Construction/Loadline
Issued 23 October 1996
Resolved
Replace buckled angle supports for potable water tank, remove doubler plateand provide insert on aft end of tank.
Documentation
Issued 21 October 1993
Resolved
PROVIDE ONBOARD A USCG APPROVED OPERATIONS MANUAL.
Documentation
Issued 13 October 1992
Resolved
SUBMIT FOR APPROVAL TO MSC STABILITY INFORMATION/CALCULATIONS WITH AN INFO COPY TO [name withheld].
Documentation
Issued 13 October 1992
Resolved
PROVIDE ONBOARD A USCG APPROVED OPERATIONS MANUAL.
Electrical
Issued 1 February 1990
Resolved
REPLACE GENERATOR FUEL FILTER FLEXIBLE HOSE WITH USCG APPROVED FLEXIBLE HOSE.
Documentation
Issued 1 February 1990
Resolved
SUBMIT FOR REVIEW AND APPROVAL AN OPERATING MANUEL TO MSO NEW ORLEANS TO FORWARD TO COMMANDANT (GMSC). OPERATING MANUEL MUST INCLUDE LOCATION AND REPAIR PROCEDURES FOR ALL HIGH TENSILE STEEL USED IN CONSTRUCTION.
Documentation
Issued 1 February 1990
Resolved
SUBMIT FOR REVIEW AND APPROVAL THE FOLLOWING PLANS TO MSO NEW ORLEANS FOR FORWARDING TO COMMANDANT (GMSC): INBOARD AND OUTBOARD PROFILES, GENERAL ARRANGEMENTS, STABILITY CALCULATIONS, LEG AND JACKING SYSTEM STRUCTURES ANDHYDRAULIC SYSTEMS.
Casualty record · 1
21 August 2023Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 7816474
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.