L/B 101 SELECT

L/B 101 SELECT is a 1977 offshore supply vessel. The Coast Guard has recorded 39 inspections since 1990, most recently in August 2023, along with 57 deficiencies and 1 casualty investigation in 2023.

Records from 1990 to 2023. Most recent: inspection, 21 August 2023.

Built
1977
Last inspected
21 August 2023
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDE7530
152543
Flag
UNITED STATES
366742890, 367394360 (licence lapsed)
Maury page id
psix-152543

Inspections, by type

…with no type recorded6
Years with a record 22 calendar years (1990–2023)
The 39 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)46.0 ft × 18.1 ft × 4.6 ft
Registered tonnagegross 45 / net 40
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderELEVATING BOATS INC · CAERNARVON, LA, UNITED STATES · built 1977
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBELLE CHASSE, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 25 August 2026 · expires 31 August 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it45 - Regulatory (Subpart C or D), Gross Ton
40 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDE7530MMSI 367394360 · expired · voluntarily equipped · granted 7 February 2009, cancelled 13 April 2019 · licensed under a name not among this hull’s recorded names (not shown)
WAH9204MMSI 366742890 · expired · compulsorily equipped · granted 15 January 1998, cancelled 19 February 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 39

21 August 2023 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7816474
31 May 2019 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6699353
25 August 2018 Type not recorded
No type recorded · USCGC SAILFISH (WPB 87356) · USCG Northeast District (CGD-NE) · Activity 6522821
5 July 2018 Examination of Repairs · Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6458401
5 June 2017 Administrative Inspection · Examination of Repairs · Plan Review (Other than "T") · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6166479
18 March 2016 Examination of Repairs · Deficiency Check · COI Inspection · Drydock Exam · Internal Structural Exam · MTSA/ISPS Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5834329
6 March 2014 Annual Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4806666
22 February 2012 Deficiency Check · Drydock Exam · Internal Structural Exam · Annual Inspection · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4245526
25 February 2011 Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3951105
30 December 2008 COI Inspection · Hull Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3383624
1 November 2007 Examination of Repairs · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3089057
2 February 2007 Deficiency Check · Examination of Repairs · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2866122
16 April 2004 Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2045335
5 November 2002 Administrative Inspection
Administrative · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1701298
24 October 2002 Annual Inspection · Hull Examination
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1695278
18 April 2000 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1049310
14 January 2000 Re-Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1381773
23 October 1998 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1446696
30 October 1997 Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1383687
31 October 1996 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1388155
23 October 1996 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1434470
20 December 1995 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1385600
30 January 1995 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1380154
27 October 1994 COI Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1429951
2 June 1994 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1164450
23 February 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 852963
30 November 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 666060
21 October 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 214176
21 October 1993 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 644364
21 October 1993 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1394005
19 October 1993 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 171311
23 November 1992 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 830053
13 October 1992 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1267803
24 July 1992 Inclining Experiment
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 957489
28 January 1992 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1315575
21 October 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 942818
18 December 1990 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 903736
19 November 1990 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1243857
1 February 1990 Initial Certification · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 916443

Deficiency record · 57

08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 31 May 2019 Resolved
Vessels tilt alarm did not sound when vessel listed more that 2 degress. Tilt alarm shall be repaired prior to using jacking system.
Action required: 705 - Other - as specified
Due 1 July 2019
Resolved 10 June 2019
Resolution: Verified tilt systme sounded and visually alarmed when needed.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 5 July 2018 Resolved
Operation of transmitters of any ship station must be performed by a person holding a commercial radio operator license or permit of the class required below. No crew member on board had FCC operators permit. 47 CFR 80.155
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 24 August 2018
Resolution: Master aquired FCC operators permit
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 5 July 2018 Resolved
Stations in the maritime service must be licensed by the FCC either individually or by fleet. Vessel did not have station license on board. 47 CFR 80.13(a)
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 24 August 2018
Resolution: FCC Station license on board
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Health protection, medical care?)
Issued 5 July 2018 Resolved
Each EAP education program must include at least the following elements: display and distribution of informational material; display and distribution of a community service hot-line telephone number for crew member assistance, and display and distribution of the employer's policy regarding drug and alcohol use in the workplace. Vessel did not have EAP info displayed.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 August 2018
Resolution: Vessel dispayed EAP info.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 5 July 2018 Resolved
Natural vents connected to the engine room and deck-house should have weather-tight closures that are appropriately marked, "close in case of fire". renew gasket to engine room closure. 46 CFR176.25-1(a) old-t CG-543 Policy letter 07-02
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 July 2018
Resolution: Gasket renewed
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 July 2018 Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy. Found waterlight Secured to throw line, re-attach around body of ring life buoy.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 July 2018
Resolution: Line correctly attached.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 5 July 2018 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: A space with a through-hull fitting below the deepest load waterline; A machinery space bilge; and A space with a non-watertight closure. Vessel hydraulic tank lvl alarm was not working properly.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 July 2018
Resolution: Sat repair
07 - Fire Safety › N/A - No Subsystem › Jacketed high pressure lines and oil leakage alarm
Issued 5 July 2018 Resolved
In accordance with standards acceptable to the OCMI as as good marine practice. Observed fuel leak on auxiliary engine outboard fuel injector. 46 CFR176.25-1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 24 July 2018
Resolution: Tightened fittings, no observed leakage.
Documentation › Markings/Placards › Official Number (US)
Issued 5 June 2017 Resolved
Vessel name was not on the vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 30 June 2017
Resolution: Vsl correctly marked as per COD.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 5 June 2017 Resolved
AL test strips expired.
Condition: Improper/Lack of Maintenance
Due 1 July 2017
Resolved 30 June 2017
Resolution: Provided
Documentation › Manuals/Policy Documentation › Operations Manual (Incinerator)
Issued 5 June 2017 Resolved
Liftboat ops manual was for a prior company and vsl name. Update and resubmitt for approval.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 August 2017
Resolved 28 August 2017
Resolution: Updated operations manual was provided.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 5 June 2017 Resolved
Expired
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 July 2017
Resolved 30 June 2017
Resolution: Provided
Documentation › Certificates/Documents › FCC SSL
Issued 5 June 2017 Resolved
Missing
Action required: 705 - Other - as specified
Due 26 July 2017
Resolved 30 June 2017
Resolution: Provided
Documentation › Certificates/Documents › FCC SSL
Issued 5 June 2017 Resolved
No crewmember onboard the FCC liscence.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 30 June 2017
Resolution: Provided
Communications › Alarms/Indicators › Collision Alarm
Issued 5 June 2017 Resolved
Tilt alarm for 1.2* not working. Remove toggle switch to disable alarms.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 June 2017
Resolution: Alarm fixed and working. Toggle cut out switch removed.
Stability › Watertight Integrity › General
Issued 5 June 2017 Resolved
Hole from old pipe in stbd sideshell.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 June 2017
Resolution: Doubler installed on interior of the hull.
Navigation › Piloting/Steering › Marine Charts
Issued 5 June 2017 Resolved
Provide charts of correct scale and NTM.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2017
Resolution: Provided
Engineering › Fuel Oil Service System › Valve
Issued 5 June 2017 Resolved
Stbd fuel shutoff not working.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 June 2017
Resolution: Fixed and tested.
Engineering › Engine Controls (Electric/Electronic) › Linkage
Issued 18 March 2016 Resolved
Linkage for throttle control has complete fracture at main engine.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 March 2016
Resolved 8 April 2016
Resolution: Company fabricated new linlage.
Lifesaving › Lifefloat › Serviceable
Issued 18 March 2016 Resolved
Life float has severe damage on underside. Repair/replace as necessary. After repairs, ensure grab line is properly routed around life float body, not lifeline.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 March 2016
Resolved 8 April 2016
Resolution: REpairs made to the satisfaction of the MI.
Electrical › Electric Generation Source (service) › Generator
Issued 18 March 2016 Resolved
Generator windings are coated with dirt and oil. Identify source of oil and repair/clean as necessary
Action required: 17 - Rectify deficiencies prior to departure
Due 18 March 2016
Resolved 8 April 2016
Resolution: Generator properly cleaned.
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 18 March 2016 Resolved
Anchor chain has severe wastage coming off of anchor. Replace as necessary.
Due 25 March 2016
Resolved 8 April 2016
Resolution: Anchor chain replaced.
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 18 March 2016 Resolved
Port side hydraulic gear box is leaking. Deck has no containment. Fix hydraulic leaks.
Due 25 March 2016
Resolved 8 April 2016
Resolution: Hydraulic leaks repaired.
Construction/Loadline › Penetrations › Weld
Issued 18 March 2016 Resolved
Repair exhaust leaks on main engine piping and wastage where exhaust passes thru deck.
Due 18 April 2016
Resolved 8 April 2016
Resolution: Leaks and thru deck areas replaced with good metal.
Lifesaving › Lifebuoys › Serviceable
Issued 18 March 2016 Resolved
Ring buoy is missing plug. Check with manufacturer, determine repair/replacement options to ensure vessel has functional life ring. Additionally, float light should have appropriate corrosion resistant clip for connecting to life ring.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 March 2016
Resolved 8 April 2016
Resolution: Ring buoy replaced.
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 18 March 2016 Resolved
Aft and port windows on bridge have spiderweb cracks. Replace with approved glass.
Due 18 April 2016
Resolved 8 April 2016
Resolution: Windows replaced.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 March 2016 Resolved
Port and starboard navigation lights are improperly installed. Reposition lights for proper visibility in accordance with Nav Rules
Action required: 17 - Rectify deficiencies prior to departure
Due 18 March 2016
Resolved 8 April 2016
Resolution: Nav lights properly installed.
Electrical › Electric Supply System (service) › Cable
Issued 18 March 2016 Resolved
02 Junction boxes in engine room lacking appropriate covers. Replace/cover boxes as needed.
Due 18 April 2016
Resolved 8 April 2016
Resolution: Junction boxes properly coverd.
Electrical › Electric Supply System (service) › Cable
Issued 18 March 2016 Resolved
Wiring harness above Main Engine has melted cover. Replace wiring as necessary.
Due 18 April 2016
Resolved 8 April 2016
Resolution: Harness cover replaced.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type 1
Issued 18 March 2016 Resolved
Type 1 MSD currently installed on liftboat is only approved for uninspected vessels. Device is not compliant with SUB J or F.
Due 8 May 2016
Resolved 11 August 2016
Resolution: Authorized MSD installed to the satisfaction of the MI.
Communications › Alarms/Indicators › Bilge Alarm
Issued 22 February 2012 Resolved
Prove proper operation of bilge alarm.
Due 9 April 2012
Resolved 11 October 2012
Fire Fighting › Fire Pumps › Pressure
Issued 22 February 2012 Resolved
Fire pump must meet requirement of 60psi.
Due 9 April 2012
Resolved 11 October 2012
Electrical › Electric Supply System (service) › Cable
Issued 3 March 2011 Resolved
Provide electrian report, removal of splices and install junction box for bilge alarm and pump wiring.
Action required: 705 - Other - as specified
Due 31 March 2011
Resolved 11 March 2011
Resolution: Provided electrian receipt of work performed of bilge wiring system
Electrical › Electric Supply System (service) › Cable
Issued 3 March 2011 Resolved
Fix visual indication on low hydraulic oil alarm
Action required: 705 - Other - as specified
Due 31 March 2011
Resolved 11 March 2011
Resolution: Provided electrian receipt that visual low hydraulic oil alarm light was working properly
Electrical › Electric Supply System (service) › Battery Charger
Issued 2 March 2011 Resolved
Hardwire battery chargers, no extension cords shall be used for permenant electrical installations.
Action required: 705 - Other - as specified
Due 2 April 2011
Resolved 3 March 2011
Resolution: Battery charger installations hardwired, no extensions are being used for permenant electrical installations
Engineering › Fuel Oil Service System › Piping
Issued 2 March 2011 Resolved
Provide supports for fuel lines, attach lines to longitudials by brackets or other means to reduce vibration damage.
Action required: 705 - Other - as specified
Due 2 April 2011
Resolved 3 March 2011
Resolution: Fuel lines attached to longitudials with clamps and rubber backing. vibration reduced.
Lifesaving › Lifejacket/PFD (Type III) › Quantity
Issued 25 February 2011 Resolved
Replace type 3 lifejacket with type 1 or 2.
Action required: 705 - Other - as specified
Due 3 March 2011
Resolved 3 March 2011
Resolution: replaced type 3 lifejacket with Type 1 lifejacket
Communications › Radio Communications
Issued 24 October 2002 Resolved
Provide current FCC radio station license. LEGACY COMPONENT DESC: VFH Radiotelephone
Due 24 November 2002
Resolved 16 April 2004
Documentation › Certificates/Documents
Issued 24 October 2002 Resolved
Provide original COI for the vessel. LEGACY COMPONENT DESC: Certificate of Inspection
Due 24 November 2002
Resolved 16 April 2004
Engineering
Issued 14 January 2000 Resolved
Install fuel shut-off valve on supply line at ship service gen.
Condition: Unknown
Due 14 January 2000
Resolved 14 January 2000
Electrical
Issued 14 January 2000 Resolved
Install blanks in generator distribution panel.
Condition: Unknown
Due 14 January 2000
Resolved 14 January 2000
Engineering
Issued 14 January 2000 Resolved
Install lagging or shield on main diesel engine exhaust.
Condition: Unknown
Due 14 January 2000
Resolved 14 January 2000
Deck/Cargo
Issued 14 January 2000 Resolved
Install hydraulic supply hose meeting ASME J-1942 with ends meeting SAE J- 1475 for hydraulic crane.
Condition: Unknown
Due 14 January 2000
Resolved 14 January 2000
Engineering
Issued 14 January 2000 Resolved
Install fuel shut-off valves with reach rods located out side of the comp. for each fuel tank supply valve.
Condition: Unknown
Due 14 January 2000
Resolved 14 January 2000
Lifesaving
Issued 14 January 2000 Resolved
Provide and install retro tape on ring bouy.
Condition: Unknown
Due 14 January 2000
Resolved 14 January 2000
Navigation
Issued 14 January 2000 Resolved
Provide updated navigation pubs.
Condition: Unknown
Due 14 January 2000
Resolved 14 January 2000
Lifesaving
Issued 14 January 2000 Resolved
Provide and install retro tape on life boat.
Condition: Unknown
Due 14 January 2000
Resolved 14 January 2000
Construction/Loadline
Issued 23 October 1996 Resolved
Replace sump tank hose to pipe connections on deck and provide double hose clamps.
Condition: Unknown
Due 23 October 1996
Resolved 23 October 1996
Navigation
Issued 23 October 1996 Resolved
Provide chart of operating area, tide tables, and 46 CFR 166-199.
Condition: Unknown
Due 23 October 1996
Resolved 23 October 1996
Lifesaving
Issued 23 October 1996 Resolved
Provide retro reflective tape for resue boat.
Condition: Unknown
Due 23 October 1996
Resolved 23 October 1996
Construction/Loadline
Issued 23 October 1996 Resolved
Replace buckled angle supports for potable water tank, remove doubler plateand provide insert on aft end of tank.
Condition: Unknown
Due 23 October 1996
Resolved 23 October 1996
Documentation
Issued 21 October 1993 Resolved
PROVIDE ONBOARD A USCG APPROVED OPERATIONS MANUAL.
Condition: Unknown
Due 21 October 1993
Resolved 21 October 1993
Documentation
Issued 13 October 1992 Resolved
SUBMIT FOR APPROVAL TO MSC STABILITY INFORMATION/CALCULATIONS WITH AN INFO COPY TO [name withheld].
Condition: Unknown
Due 13 October 1992
Resolved 13 October 1992
Documentation
Issued 13 October 1992 Resolved
PROVIDE ONBOARD A USCG APPROVED OPERATIONS MANUAL.
Condition: Unknown
Due 13 October 1992
Resolved 13 October 1992
Electrical
Issued 1 February 1990 Resolved
REPLACE GENERATOR FUEL FILTER FLEXIBLE HOSE WITH USCG APPROVED FLEXIBLE HOSE.
Condition: Unknown
Due 1 February 1990
Resolved 1 February 1990
Documentation
Issued 1 February 1990 Resolved
SUBMIT FOR REVIEW AND APPROVAL AN OPERATING MANUEL TO MSO NEW ORLEANS TO FORWARD TO COMMANDANT (GMSC). OPERATING MANUEL MUST INCLUDE LOCATION AND REPAIR PROCEDURES FOR ALL HIGH TENSILE STEEL USED IN CONSTRUCTION.
Condition: Unknown
Due 1 February 1990
Resolved 1 February 1990
Documentation
Issued 1 February 1990 Resolved
SUBMIT FOR REVIEW AND APPROVAL THE FOLLOWING PLANS TO MSO NEW ORLEANS FOR FORWARDING TO COMMANDANT (GMSC): INBOARD AND OUTBOARD PROFILES, GENERAL ARRANGEMENTS, STABILITY CALCULATIONS, LEG AND JACKING SYSTEM STRUCTURES ANDHYDRAULIC SYSTEMS.
Condition: Unknown
Due 1 February 1990
Resolved 1 February 1990

Casualty record · 1

21 August 2023Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 7816474
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.