08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 31 May 2019
Resolved
Vessels tilt alarm did not sound when vessel listed more that 2 degress. Tilt alarm shall be repaired prior to using jacking system.
Action required: 705 - Other - as specified
Due 1 July 2019
Resolved 10 June 2019
Resolution: Verified tilt systme sounded and visually alarmed when needed.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 5 July 2018
Resolved
Operation of transmitters of any ship station must be performed by a person holding a commercial radio operator license or permit of the class required below. No crew member on board had FCC operators permit.
47 CFR 80.155
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 24 August 2018
Resolution: Master aquired FCC operators permit
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 5 July 2018
Resolved
Stations in the maritime service must be licensed by the FCC either individually or by fleet. Vessel did not have station license on board.
47 CFR 80.13(a)
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 24 August 2018
Resolution: FCC Station license on board
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Health protection, medical care?)
Issued 5 July 2018
Resolved
Each EAP education program must include at least the following elements: display and distribution of informational material; display and distribution of a community service hot-line telephone number for crew member assistance, and display and distribution of the employer's policy regarding drug and alcohol use in the workplace. Vessel did not have EAP info displayed.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 August 2018
Resolution: Vessel dispayed EAP info.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 5 July 2018
Resolved
Natural vents connected to the engine room and deck-house should have weather-tight closures that are appropriately marked, "close in case of fire". renew gasket to engine room closure.
46 CFR176.25-1(a) old-t
CG-543 Policy
letter 07-02
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 July 2018
Resolution: Gasket renewed
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 July 2018
Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy. Found waterlight Secured to throw line, re-attach around body of ring life buoy.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 July 2018
Resolution: Line correctly attached.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 5 July 2018
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: A space with a through-hull fitting below the deepest load waterline; A machinery space bilge; and A space with a non-watertight closure. Vessel hydraulic tank lvl alarm was not working properly.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 July 2018
Resolution: Sat repair
07 - Fire Safety › N/A - No Subsystem › Jacketed high pressure lines and oil leakage alarm
Issued 5 July 2018
Resolved
In accordance with standards acceptable to the OCMI as
as good marine practice. Observed fuel leak on auxiliary
engine outboard fuel injector.
46 CFR176.25-1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 24 July 2018
Resolution: Tightened fittings, no observed leakage.
Documentation › Markings/Placards › Official Number (US)
Issued 5 June 2017
Resolved
Vessel name was not on the vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 30 June 2017
Resolution: Vsl correctly marked as per COD.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 5 June 2017
Resolved
AL test strips expired.
Condition: Improper/Lack of Maintenance
Due 1 July 2017
Resolved 30 June 2017
Resolution: Provided
Documentation › Manuals/Policy Documentation › Operations Manual (Incinerator)
Issued 5 June 2017
Resolved
Liftboat ops manual was for a prior company and vsl name. Update and resubmitt for approval.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 August 2017
Resolved 28 August 2017
Resolution: Updated operations manual was provided.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 5 June 2017
Resolved
Expired
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 July 2017
Resolved 30 June 2017
Resolution: Provided
Documentation › Certificates/Documents › FCC SSL
Issued 5 June 2017
Resolved
Missing
Action required: 705 - Other - as specified
Due 26 July 2017
Resolved 30 June 2017
Resolution: Provided
Documentation › Certificates/Documents › FCC SSL
Issued 5 June 2017
Resolved
No crewmember onboard the FCC liscence.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 30 June 2017
Resolution: Provided
Communications › Alarms/Indicators › Collision Alarm
Issued 5 June 2017
Resolved
Tilt alarm for 1.2* not working. Remove toggle switch to disable alarms.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 June 2017
Resolution: Alarm fixed and working. Toggle cut out switch removed.
Stability › Watertight Integrity › General
Issued 5 June 2017
Resolved
Hole from old pipe in stbd sideshell.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 June 2017
Resolution: Doubler installed on interior of the hull.
Navigation › Piloting/Steering › Marine Charts
Issued 5 June 2017
Resolved
Provide charts of correct scale and NTM.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2017
Resolution: Provided
Engineering › Fuel Oil Service System › Valve
Issued 5 June 2017
Resolved
Stbd fuel shutoff not working.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 June 2017
Resolution: Fixed and tested.
Engineering › Engine Controls (Electric/Electronic) › Linkage
Issued 18 March 2016
Resolved
Linkage for throttle control has complete fracture at main engine.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 March 2016
Resolved 8 April 2016
Resolution: Company fabricated new linlage.
Lifesaving › Lifefloat › Serviceable
Issued 18 March 2016
Resolved
Life float has severe damage on underside. Repair/replace as necessary. After repairs, ensure grab line is properly routed around life float body, not lifeline.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 March 2016
Resolved 8 April 2016
Resolution: REpairs made to the satisfaction of the MI.
Electrical › Electric Generation Source (service) › Generator
Issued 18 March 2016
Resolved
Generator windings are coated with dirt and oil. Identify source of oil and repair/clean as necessary
Action required: 17 - Rectify deficiencies prior to departure
Due 18 March 2016
Resolved 8 April 2016
Resolution: Generator properly cleaned.
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 18 March 2016
Resolved
Anchor chain has severe wastage coming off of anchor. Replace as necessary.
Due 25 March 2016
Resolved 8 April 2016
Resolution: Anchor chain replaced.
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 18 March 2016
Resolved
Port side hydraulic gear box is leaking. Deck has no containment. Fix hydraulic leaks.
Due 25 March 2016
Resolved 8 April 2016
Resolution: Hydraulic leaks repaired.
Construction/Loadline › Penetrations › Weld
Issued 18 March 2016
Resolved
Repair exhaust leaks on main engine piping and wastage where exhaust passes thru deck.
Due 18 April 2016
Resolved 8 April 2016
Resolution: Leaks and thru deck areas replaced with good metal.
Lifesaving › Lifebuoys › Serviceable
Issued 18 March 2016
Resolved
Ring buoy is missing plug. Check with manufacturer, determine repair/replacement options to ensure vessel has functional life ring. Additionally, float light should have appropriate corrosion resistant clip for connecting to life ring.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 March 2016
Resolved 8 April 2016
Resolution: Ring buoy replaced.
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 18 March 2016
Resolved
Aft and port windows on bridge have spiderweb cracks. Replace with approved glass.
Due 18 April 2016
Resolved 8 April 2016
Resolution: Windows replaced.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 March 2016
Resolved
Port and starboard navigation lights are improperly installed. Reposition lights for proper visibility in accordance with Nav Rules
Action required: 17 - Rectify deficiencies prior to departure
Due 18 March 2016
Resolved 8 April 2016
Resolution: Nav lights properly installed.
Electrical › Electric Supply System (service) › Cable
Issued 18 March 2016
Resolved
02 Junction boxes in engine room lacking appropriate covers. Replace/cover boxes as needed.
Due 18 April 2016
Resolved 8 April 2016
Resolution: Junction boxes properly coverd.
Electrical › Electric Supply System (service) › Cable
Issued 18 March 2016
Resolved
Wiring harness above Main Engine has melted cover. Replace wiring as necessary.
Due 18 April 2016
Resolved 8 April 2016
Resolution: Harness cover replaced.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type 1
Issued 18 March 2016
Resolved
Type 1 MSD currently installed on liftboat is only approved for uninspected vessels. Device is not compliant with SUB J or F.
Due 8 May 2016
Resolved 11 August 2016
Resolution: Authorized MSD installed to the satisfaction of the MI.